• Title/Summary/Keyword: Linearity Error

Search Result 288, Processing Time 0.026 seconds

A Study on the Improvement of Efficiency and Linearity of Power Amplifier using PBG Structure (PBG 구조를 이용한 전력 증폭기의 효율 및 선형성 개선에 관한 연구)

  • 김병희;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1182-1190
    • /
    • 2001
  • In this paper, microstrip photonic bandgap (PBG) structure with special perforation patterns etched on the line itself is analyzed and optimized in shape, then used for harmonic tuning of power amplifier. This PBG has an advantage in being fabricated and grounded. The dimension of unit lattice is enlarged vertically, but its input and output line maintain 50 Ω using tapered line. This modification from original structure can lessen possible error in etching PCB. The analysis and design of PBG structure are acquired from using EM simulation. The measured insertion loss of the final structure is 0.3 ∼0.4 dB, and its bandwidth of stopband is 6∼7 GHz. Measured results of improved characteristics by using PBG structure at the output of the power amplifier are 0.72∼0.99 dB in output power, 1.14∼7.8 % in PAE, and 1 dBc in the third IMD.

  • PDF

A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation (치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구)

  • Lee, Dong-Hun;Kwon, Jang-Woo;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.11-20
    • /
    • 1996
  • In this paper, the characteristics of therapy radiation diode sensors have been studied by using therapy radiation from the MM22 microtron accelerator. The linearity, reproducibility and error ratio were measured for feasibility as a radiation detector. Energy dependence, sensitivity change after a amount of irradiation and output value according to a number of diodes were also measured for same purpose. We have formed pulse shaping of diode signal with nuclear instruments for portal image reconstruction. The percent depth dose ratio according to field size and depth was compared with that of the detector of a ion chamber. Using thirteen silicon diodes, we can directly read diode outputs on a computer monitor after A/D conversion with 16 channels analog to digital conversion board with 12 bit resolution. The possibility for portal image with diodes has been suggested from output comparison between output value with a human phantom and that without a human phantom.

  • PDF

A Detection Method for Irregularity of Ionospheric delay in Network RTK Environment (네트워크 RTK 환경에서 이온층 지연 변칙현상 검출 기법)

  • Ko, Jaeyoung;Shin, Mi Young;Han, Younghoon;Cho, Deuk Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2562-2568
    • /
    • 2015
  • This paper proposes a detection method for irregularity of ionospheric delay in network RTK (Real Time Kinematic) Environment. The linearity of network RTK correction provided to user can't be assured when a characteristic of temporal-spatial of ionospheric delay is rapidly changed due to geomagnetic storm or solar flare. Therefore, incorrect ambiguity can be resolved and positioning error can be increased. A detection method for irregularity of ionospheric delay is needed to provide reliable correction. In this paper, index to detect irregularity of ionospheric delay is calculated from dispersive corrections and occurrence of irregularity is judged by comparing index and thresholds.

Development of Empirical Formulas for Storage Function Method (저류함수법의 매개변수 산정식 개발)

  • Choi, Jong-Nam;Ahn, Won-Shik;Kim, Tae-Gyun;Chung, Gun-Hui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.125-130
    • /
    • 2009
  • Storage function method which considers the non-linearity of the relationship between rainfall and runoff has been frequently used to predict runoff in a basin and a flood pattern. However, it is time-consuming to estimate appropriate parameters of every basin and rainfall event, which requires the empirical parameter equation applicable in Korea. In this study, multiple regression analysis is used to develop empirical equations to estimate parameters of Storage Function method using basin characteristics. The basin area, maximum stream length, and stream slope are considered as the basin characteristics as the result of the regression analysis. Collinearity is removed and trial-and-error method is used to choose the most descriptive parameters to the dependent variables in Han River basin which is divided into 30 subbasins. The developed equations are validated using the rainfall events in MunMak gauging station and named as 'Han River equation'. The equation could provide the useful information about Storage Function method parameter to calculate runoff from a basin and predict river stage.

Design & Fabrication of a Feedforward Power Amplifier for 900 MHz Band RFID Readers (900 MHz 대역 RFID 리더기용 Feedforward형 선형 전력 증폭기 설계 및 제작)

  • Jung, Byoung-Hee;Chae, Gyu-Sung;Kim, Chang-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.2
    • /
    • pp.184-190
    • /
    • 2004
  • A feedforward linear power amplifier (FLPA) has been developed for UHF-band RFID reader applications. The main and error amplifiers are composed of a 2 stage so that linearity of the FLPA can be improved. The FLPA has been implemented on an FR-4 substrate (Er=4.7 and thickness=0.8 mm) with 3-dB and 10-dB hybrid couplers for input/output power divider and combiner. For 2-tone measurement (input level=-11 dBm at $f_1$=915 MHz and $f_2$=916 MHz), the FLPA exhibits a -18.52 dBm of $IMD_3$, which indicates that $IMD_3$ cancellation with feedforward loop is more than 27 dB. From 890 to 960 MHz, 1-dB gain compression output power and power gain of the FLPA are higher than 30 dBm and 40 dB, respectively.

  • PDF

Genetic Algorithm Calibration Method and PnP Platform for Multimodal Sensor Systems (멀티모달 센서 시스템용 유전자 알고리즘 보정기 및 PnP 플랫폼)

  • Lee, Jea Hack;Kim, Byung-Soo;Park, Hyun-Moon;Kim, Dong-Sun;Kwon, Jin-San
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.69-80
    • /
    • 2019
  • This paper proposes a multimodal sensor platform which supports plug and play (PnP) technology. PnP technology automatically recognizes a connected sensor module and an application program easily controls a sensor. To verify a multimodal platform for PnP technology, we build up a firmware and have the experiment on a sensor system. When a sensor module is connected to the platform, a firmware recognizes the sensor module and reads sensor data. As a result, it provides PnP technology to simply plug sensors without any software configuration. Measured sensor raw data suffer from various distortions such as gain, offset, and non-linearity errors. Therefore, we introduce a polynomial calculation to compensate for sensor distortions. To find the optimal coefficients for sensor calibration, we apply a genetic algorithm which reduces the calibration time. It achieves reasonable performance using only a few data points with reducing 97% error in the worst case. The platform supports various protocols for multimodal sensors, i.e., UART, I2C, I2S, SPI, and GPIO.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

High Efficiency Power Amplifier applied to 5G Systems (5G 시스템에 적용되는 고효율 전력증폭기)

  • Young Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.197-202
    • /
    • 2023
  • This paper presents the design method and electrical characteristics of a high-efficiency power amplifier for a 50 Watts class repeater applied to a 5G system and used in in-building, subway, and tunnel. GaN was used for the termination transistor of the power amplifier designed here, and intermodulation signals were removed using DPD to satisfy linearity. In addition, in order to handle various requirements such as amplifier gain control and alarm processing required in the 5G system, the microprocessor is designed to exist inside the power amplifier. The amplifier manufactured to confirm the electrical performance of the power amplifier satisfying these conditions satisfied 46.5 dBm and the overall efficiency of the amplifier was 37%, and it was confirmed that it satisfied various alarm conditions and electrical characteristics required by telecommunication companies.

Time-optimized Color Conversion based on Multi-mode Chrominance Reconstruction and Operation Rearrangement for JPEG Image Decoding (JPEG 영상 복원을 위한 다중 모드 채도 복원과 연산 재배열 기반의 시간 최적화된 컬러 변환)

  • Kim, Young-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.1
    • /
    • pp.135-143
    • /
    • 2009
  • Recently, in the mobile device, the increase of the need for encoding and decoding of high-resolution images requires an efficient implementation of the image codec. This paper proposes a time-optimized color conversion method for the JPEG decoder, which reduces the number of calculations in the color conversion by the rearrangement of arithmetic operations being possible due to the linearity of the IDCT and the color conversion matrices and brings down the time complexity of the color conversion itself by the integer mapping replacing floating-point operations to the optimal fixed-point shift and addition operations, eventually reducing the time complexity of the JPEG decoder. And the proposed method compensates a decline of image quality incurred by the quantification error of the operation arrangement and the integer mapping by using the multi-mode chrominance reconstruction. The performance evaluation performed on the development platform of embedded systems showed that, compared to previous color conversion methods, the proposed method greatly reduces the image decoding time, minimizing the distortion of decoded images.

Analysis of Corporate Value Relevance Form of Tax Avoidance (조세회피의 기업가치 관련성 형태 분석)

  • Gee-Jung Kwon
    • Asia-Pacific Journal of Business
    • /
    • v.14 no.4
    • /
    • pp.233-254
    • /
    • 2023
  • Purpose - This study aims to verify whether the effect of tax avoidance on corporate value is non-linear in the Korean financial markets. Design/methodology/approach - This study believes that the cause of the inconsistent empirical analysis results of previous studies that verified the relationship between tax avoidance and firm value may be an error in assuming linearity, and verifies whether a nonlinear relationship exists. The sample company in this study is a December settlement corporation listed on the Korean stock market, and the analysis period is from 2000 to 2021. In the empirical analysis model, Tobin's Q is used as a proxy for corporate value, tax avoidance is used as the main independent variable, and a regression model is designed with corporate size, growth rate, and debt ratio set as control variables. Findings - As a result of the empirical analysis, it can be confirmed that there is an inverted U-shaped nonlinear relationship between tax avoidance and corporate value. In the additional analysis using Ohlson (1995) firm valuation model for the robustness of the results of the empirical analysis, the same nonlinear value relationship between tax avoidance can be confirmed. Research implications or Originality - This study is considered to be meaningful in that it verifies the non-linear relationship of tax avoidance, which has not been attempted in previous studies. The meaning of the inverted U-shaped nonlinear relationship presented in this study is that corporate tax avoidance acts as a factor that increases corporate value up to a certain level, but rather becomes a factor that decreases corporate value when it exceeds a critical point. These results are expected to provide new perspectives and perspectives on tax avoidance to companies belonging to the Korean capital market.