• Title/Summary/Keyword: Linear motion ball guide

Search Result 22, Processing Time 0.018 seconds

Development of a Robotic System for Measuring Hole Displacement Using Contact-Type Displacement Sensors (접촉식 변위센서를 이용한 홀 변위 측정 로봇시스템 개발)

  • Kang, Hee-Jun;Kweon, Min-Ho;Suh, Young-Soo;Ro, Young-Shick
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • For the precision measurement of industrial products, the location of holes inside the products, if they exist, are often selected as feature points. The measurement of hole location would be performed by vision and laser-vision sensor. However, the usage of those sensors is limited in case of big change of light intensity and reflective shiny surface of the products. In order to overcome the difficulties, we have developed a hole displacement measuring device using contact-type displacement sensors (LVDTs). The developed measurement device attached to a robot measures small displacement of a hole by allowing its X-Y movement due to the contact forces between the hole and its own circular cone. The developed device consists of three plates which are connected in series for its own function. The first plate is used for the attachment to an industrial robot with ball-bush joints and springs. The second and third plates allow X-Y direction as LM guides. The bottom of the third plate is designed that various circular cones can be easily attached according to the shape of the hole. The developed system was implemented for its effectiveness that its measurement accuracy is less than 0.05mm.

Evaluation of Electrohydraulic Left Ventricular Assist Device through Animal Experiment (동물실험을 통한 전기유압식 좌심실 보조장치의 성능 평가)

  • Choi, J.S.;Chung, C.I.;Choi, W.W.;Park, S.K.;Jo, Y.H.;Om, K.S.;Lee, J.J.;Won, Y.S.;Kim, H.C.;Kim, W.G.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.84-87
    • /
    • 1996
  • We have been developed electrohydraulic left ventricular assist device and done various in vivo evaluation on the device. Through the in vivo experiment conducted from Jan. 23, 1996 to Feb. 8, we could have experience of long-term evaluation fur the first time. The sheep used in this experiment had survived for 16 days. We used new actuator with reduced size and linear motion guide replacing oil box and ball bearings. Also, we used improved blood chamber with reduced size, reduced weight facilitating fixing the chamber to animal's body, and polymer sac having improved folding pattern. Against suction problem, we used absolute pressure limiter only. Motor current for driving this new actuator was not much higher than older one. Effective stroke volume was about 48 cc. Thrombosis was found around top area and peripheral boundary of the sac and valves. There was no sign of damage from suction problem in the atrium observed at autopsy. Main cause of death was presumed to be progressive formation of thrombosis in the cannulae. In this paper, the results of this experiment are documented.

  • PDF