Improved Adhesion of DLC Films by using a Nitriding Layer on AISI H13 Substrate

  • Park, Min-Seok;Kim, Dae-Young;Shin, Chang-Seouk;Kim, Wang Ryeol
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.307-314
    • /
    • 2021
  • Diamond-like carbon (DLC) is difficult to achieve sufficient adhesion because of weak bonding between DLC film and the substrate. The purpose of this study is to improve the adhesion between substrate and DLC film. DLC film was deposited on AISI H13 using linear ion source. To improve adhesion, the substrate was treated by dual post plasma nitriding. In order to define the mechanism of the improvement in adhesive strength, the gradient layer between substrate and DLC film was analyzed by Glow Discharge Spectrometer (GDS) and Scanning Electron Microscope (SEM). The microstructure of the DLC film was analyzed using a micro Raman spectrometer. Mechanical properties were measured by nano-indentation, micro vickers hardness tester and tribology tester. The characteristic of adhesion was observed by scratch test. The adhesion of the DLC film was enhanced by active screen plasma nitriding layer.

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.31 no.2
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

The Change in Geotechnical Properties of the Deposited Clay Contaminated by Leachate from Waste Disposals (침출수로 오염된 퇴적점토의 역학적 특성변화)

  • Ha, Kwang-Hyun;Lee, Sang-Eun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.43-54
    • /
    • 2006
  • In this paper, the uniaxial, triaxial compression tests and consolidation tests on the clay sample substituted initial pore water for pollutant were performed to evaluate the change in geotechnical properties of the contaminated clay. The contaminant transport analysis on embankment type landfill using the MT3D model was also performed to evaluate the extent of transport and diffusion. There was tendency that strength, compressibility and permeability has increased with the increase in the concentration of NaCl solution. The increase in the strength and compressibility of sample saturated with leachate was higher than samples saturated with NaCl solution, but in the permeability coefficient was lower. As the result of contaminant transport analysis, the predicted concentration was in high with the increase in the initial concentration of $Cl^-$ ion and increased in a non-linear form. The transportation distance calculated with use of regression equation between the distance from contaminant source and the concentration of $Cl^-$ ion was increased with the increase in the initial concentration.

  • PDF

Roll-to-Roll 스퍼터 공정시 Ar 이온 빔 처리가 ITO 박막의 특성에 미치는 효과 연구

  • Sin, Yong-Hui;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.573-574
    • /
    • 2013
  • 본 연구에서는 Roll-to-Roll 스퍼터를 이용한 ITO 성막 공정에서 Ar 이온 빔 처리가 플렉시블 ITO 박막의 전기적, 광학적, 구조적 특성에 미치는 효과를 연구하였다. Roll-to-Roll 스퍼터를 이용하여 ITO 박막을 성막할 때 Linear ion source를 이용하여 Ar 이온을 ITO 박막에 직접 조사할 때 일어나는 ITO 박막의 변화를 분석하였다. Ar 이온 빔에 인가되는 DC 파워 변화에 따른 ITO 박막의 전기적, 광학적 특성 변화를 Hall measurement 및 UV/Visible spectrometry 분석법을 통해 확인하였다. 이온 빔 처리 공정 시 인가되는 파워가 DC 100 W일 때 $5.81{\times}10^{-4}{\Omega}-cm$으로 이온 빔 처리를 하지 않은 $1.14{\times}10^{-3}{\Omega}-cm$에 보다 낮은 비저항을 나타냄을 확인할 수 있었다. 이온 빔 처리 전/후 ITO 박막의 결정성은 포항 가속기 X-ray scattering법을 이용하여 분석하였으며, 결과를 통해 Ar 이온 빔 처리가 ITO 박막의 표면에서의 국부적인 결정성을 향상을 일으킴을 알 수 있었다. 이러한 결정성 향상이 Roll-to-Roll 스퍼터된 ITO 박막의 전기적 특성을 향상과 매우 밀접한 관계가 있음을 확인할 수 있었다. 또한 이온 빔 처리 전/후 ITO/CPI의 기판 휨에 따른 기계적 안정성을 알아보기 위해 bending frequency 60 Hz, bending radius 15mm로 bending test를 진행을 통하여 이온 빔 처리 전후 ITO 박막의 특성을 비교 확인하였다. 본 실험 결과를 통해 Ar 이온빔 조사에 의해 상온에서 결정형 ITO 박막을 CPI 기판위에 형성 할 수 있었다. 또한 최적화된 ITO 박막을 이용하여 유기 태양전지를 제작하였으며 이를 통해 Ar 이온빔 처리된 결정형 ITO의 유연 태양전지 응용 가능성을 타진하였다.

  • PDF

Multicomponent assessment and ginsenoside conversions of Panax quinquefolium L. roots before and after steaming by HPLC-MSn

  • Huang, Xin;Liu, Yan;Zhang, Yong;Li, Shuai-Ping;Yue, Hao;Chen, Chang-Bao;Liu, Shu-Ying
    • Journal of Ginseng Research
    • /
    • v.43 no.1
    • /
    • pp.27-37
    • /
    • 2019
  • Background: The structural conversions in ginsenosides induced by steaming or heating or acidic condition could improve red ginseng bioactivities significantly. In this paper, the chemical transformations of red American ginseng from fresh Panax quinquefolium L. under steaming were investigated, and the possible mechanisms were discussed. Methods: A method with reversed-phase high-performance liquid chromatography coupled with linear ion trap mass spectrometry ($HPLC-MS^n$)-equipped electrospray ionization ion source was developed for structural analysis and quantitation of ginsenosides in dried and red American ginseng. Results: In total, 59 ginsenosides of protopanaxadiol, protopanaxatriol, oleanane, and ocotillol types were identified in American ginseng before and after steaming process by matching the molecular weight and/or comparing $MS^n$ fragmentation with that of standards and/or known published compounds, and some of them were determined to be disappeared or newly generated under different steaming time and temperature. The specific fragments of each aglycone-type ginsenosides were determined as well as aglycone hydrated and dehydrated ones. The mechanisms were deduced as hydrolysis, hydration, dehydration, and isomerization of neutral and acidic ginsenosides. Furthermore, the relative peak areas of detected compounds were calculated based on peak areas ratio. Conclusion: The multicomponent assessment of American ginseng was conducted by $HPLC-MS^n$. The result is expected to provide possibility for holistic evaluation of the processing procedures of red American ginseng and a scientific basis for the usage of American ginseng in prescription.

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF

The surface morphology control of the polymeric material using a linear ion source (선형 이온 소스 적용을 통한 폴리머 소재의 표면구조 제어)

  • Sin, Min-Ho;Kim, Byeong-Jun;Park, Yeong-Bae;Kim, Do-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.141.2-141.2
    • /
    • 2016
  • 디스플레이, 센서 등 전자소자는 소형화 단계를 지나 인체 부착형 소자로의 발전을 요구하고 있다. 인체 부착을 위해서는 민감한 피부에 장시간 부착시 무해성과 탈부착의 자유로움이 요구되기에 기존의 화학물질을 활용한 접착 방식에서 개코도마뱀 또는 딱정벌레 발바닥에서 영감을 얻은 자연모사형 건식 접착 방식에 대한 연구가 활발하게 진행되고 있다. 폴리머를 이용하여 자연모사형 마이크로/나노구조 형성은 기계적으로 가공된 금형 몰딩과 후처리를 통한 매우 복잡한 공정이 요구된다. 본 연구에서는 이러한 복잡한 공정을 단순화하기 위해서 폴리머 소재에 플라즈마를 활용한 나노구조를 형성하는 방법을 소개하고자 하며, 건식 접착용 폴리머 소재(PMMA, PDMS)에 따른 표면구조 변화와 표면에너지 변화에 대한 연구를 수행하였다. 플라즈마 표면처리를 위해서 본 연구실에서 자체 개발한 선형이온소스를 활용하였으며 입사에너지, 노출시간, 사용가스에 따른 표면형상 변화를 주사전자현미경을 활용하여 관찰하였다. 또한 처리조건에 따른 표면에너지 변화를 확인하기 위해 물접촉각 변화를 측정하였다. PMMA는 입사에너지, 노출시간이 증가함에 따라 쉽게 나노기둥구조가 형성되었으나, 과도한 입사에너지 또는 노출시간에서는 표면구조가 에칭되면서 무너지는 것이 관찰되었다. 또한 PDMS는 동일한 조건에서 주름구조 형태를 보였으며 노출시간이 증가할수록 주름구조의 간격이 늘어남을 확인하였다. 본 연구 결과를 통해 나노 구조를 쉽게 제어할 수 있는 PMMA가 피부 부착형 접착 패치에 응용이 가능할 것으로 기대된다.

  • PDF

Determination of Alisol B 23-acetate and Alisol C 23-acetate in Alismatis Rhizoma by HPLC-ESI-MS

  • Ahn, Mi-Jeong;Lee, Cheol-Ho;Shin, Yong-Wook;Chun, Man-Seog;Kim, Chul-Young;Kim, Jin-Woong
    • Natural Product Sciences
    • /
    • v.14 no.3
    • /
    • pp.152-155
    • /
    • 2008
  • An HPLC-ESI-MS method has been developed to identify and quantify two main tetracyclic triterpenes, alisol B 23-acetate and alisol C 23-acetate in the Alismatis Rhizoma (Taeg-Sa). The relative distribution of the two triterpenes in the methanolic extract of commercially available Alismatis Rhizoma was established by selective ion monitoring (SIM) mode via electrospray ionization (ESI) source. Regression equations revealed good linear relationship, and the correlation coefficients were 0.999 and 0.998 for alisol B 23-acetate and alisol C 23-acetate, respectively, between the peak areas of the components and their concentration in a range of $0.06-2.0{\mu}g/mL$. It was found that there were significant differences in the amount of alisol B 23-acetate and alisol C 23-acetate between Korean and Chinese origins. The results showed that this method could be used to identify the two components in Alismatis Rhizoma with high sensitivity and selectivity.

Evidence for Sulfite Proton Symport in Saccharomyces cerevisiae

  • Park, Hoon;Alan T. Bakalinsky
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.967-971
    • /
    • 2004
  • The kinetics of sulfite uptake were examined in a wild-type laboratory strain of Saccharomyces cerevisiae to determine if carrier-mediated sulfite uptake involved a proton symport, as previous studies on sulfite uptake have suggested both an active process and facilitated diffusion. Accumulation of intracellular sulfite was initially rapid and linear up to 50 sec. Uptake was saturable at final concentrations equal to or greater than 3 mM sulfite, and increased 2-fold in the presence of 2% glucose. Uptake was significantly reduced in cells pretreated with 100-500 $\mu$M carbonyl cyanide mchlorophenylhydrazone (CCCP) or 2,4-dinitrophenol (DNP), both of which dissipate proton gradients. Uptake was also significantly inhibited in the presence of 1 mM arsenate, an inhibitor of ATP synthesis. Extracellular alkalization was observed in cells incubated with 1-2 mM sulfite in a weak tartrate buffer at pH 3.5 and 4.5. These findings suggest that the bisulfite ion, $HSO_3^-$, an anionic form of sulfite, is taken up by a carrier-mediated proton symport. A met16 sull sul2 mutant, impaired in both sulfite formation and sulfate uptake, was found able to grow on a medium with sulfite as the sole Sulfur source, indicating that the sulfate transporters Sul1p and Sul2p are not required for sulfite uptake.

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.