• 제목/요약/키워드: Linear detection

검색결과 1,537건 처리시간 0.027초

ESI-MS/MS를 이용한 소변 중 Globotriaosylceramide(Gb3)의 정량 및 임상 응용; 패브리병(Fabry) 진단 (Method Development for the Profiling Analysis of Urine Globotriaosylceramide (Gb3) for the Screening of Fabry Disease by Tandem Mass Spectrometry)

  • 윤혜란;조경희;강승우;권영주;정춘식;이용수
    • 약학회지
    • /
    • 제51권2호
    • /
    • pp.96-102
    • /
    • 2007
  • Measurement of globotriaosylceramide (Gb3, ceramide trihexoside) in urine has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. A simple, rapid, and highly sensitive analytical method for Gb3 in urine was developed without labor-extensive pre-treatment by electrospray ionization MS/MS (ESI-MS/MS). Only simple 5-fold dilution of urine is necessary for the extraction and isolation of Gb3 in urine. Gb3 in diluted urine was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Eight isoforms of Gb3 were completely resolved from urine matrix. C24:0 Gb3 occupied 50% of total Gb3 as a major component in urine. Linear relationship for Gb3 isoforms was found in the range of 0.005${\sim}$5.0 ${\mu}$g/ml. The limit of detection (S/N=5) was 0.005 ${\mu}$g/ml and limit of quantification was 0.05 ${\mu}$g/ml for C24:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9598 to 0.9975. This method could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

SPE 및 GC/MS에 의한 혈액중 스트리크닌의 분석법 개발 및 검출사례 (Method Development and Validation of Strychnine in Blood by Gas Chromatography/Mass Spectrometry Using Solid Phase Extraction and its Application in Real Specimens)

  • 이종숙;염혜선;문성민;이상기
    • 약학회지
    • /
    • 제57권2호
    • /
    • pp.87-94
    • /
    • 2013
  • An analytical methodology based on solid-space extraction (SPE) with with Bond Elut Certify cartridge (Varian, 130 mg) has been developed for the qualification and quantitation of strychnine in blood. After the elution layer was evaporated, the residue was reconstituted with methanol for GC/MS. Internal standard was used 10 mg/l dextromethorphan. Strychnine is a potent central nervous stimulant and convulsant, and an alkaloid found in seeds of Strychnos nux-vomica. It was used therapeutically to improve circulation and muscle tone in oral or intramuscular doses of 0.05~8 mg. The fatal dose of strychnine for humans is 50~100 mg. A man was found dead lying curled up the corner of the large room in a roof house after the fire fighter opened a locked door inside to put out the fire. The postmortem blood and gastric contents were analyzed for toxicological testing. Strychnine and brucine were detected using GC/MS first in gastric contents extracts. The contents of strychnine was 0.083 mg/l in heart blood, 0.088 mg/l in peripheral blood and 4.0 mg/kg in gastric contents, respectively. Method validation was carried out in terms of linearity, accuracy, precision (intraday, interday) in blood. The assay is linear over 0.05~10 mg/l ($r^2$=0.999). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.02 mg/l (S/N=3) and 0.07 mg/l (S/N=10), respectively. Accuracy (bias%) of strychnine with 0.1, 1 and 10 mg/l was 12.0% (n=6), 9.3% (n=6) and 6.9% (n=6), respectively. Intraday precision (CV%) of strychnine with, 0.1, 1 and 10 mg/l were 6.4%, 10.4%, 1.2% (n=6), respectively. Interday precision (CV%) of strychnine with 0.1, 1 and 10 mg/l over three days were 24.0%, 18.5%, 13.8% (n=18), respectively. Relative recovery with 0.1, 1 and 10 mg/l (in blood) were 114.9%, 99.3% and 87.4% (n=6), respectively. The described method can be applied in forensic toxicology to determine strychnine in blood samples.

최적 pRBFNNs 패턴분류기 기반 2차원 영상과 ASM 알고리즘을 이용한 얼굴인식 알고리즘 설계 (Design of Optimized pRBFNNs-based Face Recognition Algorithm Using Two-dimensional Image and ASM Algorithm)

  • 오성권;마창민;유성훈
    • 한국지능시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.749-754
    • /
    • 2011
  • 본 연구에서는 최적 pRBFNNs 패턴분류기 기반 2차원 영상과 ASM 알고리즘을 이용한 얼굴인식 시스템을 설계하고자 한다. 기존의 2차원 영상 기반 얼굴 인식 기법들은 인식하고자 하는 객체의 영상내의 위치, 크기 및 배경의 존재 유무에 따라 인식률이 영향을 받는 단점이 있으며, 본 연구에서는 이를 보완하기 위하여 관심 영역 내에서의 얼굴 영역 추출 및 특징 추출기법을 이용한 얼굴인식 방법을 소개한다. 본 연구에서는 CCD 카메라를 이용하여 영상을 획득하고 히스토그램 평활화를 이용하여 조명으로 왜곡된 영상정보를 개선한다. AdaBoost 알고리즘을 이용하여 얼굴영역을 검출하고 ASM을 통하여 얼굴 윤곽선 및 형상을 추출하여 개인 프로필을 구성한 후 PCA 알고리즘을 사용하여 고차원 얼굴데이터의 차원을 축소한다. 그리고 인식 모듈로서 pRBFNNs 패턴분류기를 제안한다. 제안된 다항식 기반 RBFNNs은 조건부, 결론부, 추론부 세 가지의 기능적 모듈로 구성되어 있고 조건부는 퍼지 클러스터링을 사용하여 입력 공간을 분할하고, 결론부는 분할된 로컬 영역을 다항식 함수로 표현한다. 또한 차분진화 알고리즘을 이용하여 제안된 분류기의 파라미터, 즉, 학습률, 모멘텀 계수, 퍼지 클러스터링의 퍼지화 계수를 최적화한다. 제안된 다항식 기반 RBFNNs는 얼굴 인식을 위한 패턴분류기로서 직접 CCD 카메라로부터 입력받은 데이터를 영상 보정, 얼굴 검출 및 특징 추출 등과 같은 데이터 전 처리 과정을 포함하여 고차원 데이터로 이루어진 얼굴 영상에 대한 인식 성능을 확인한다.

Photobacterium phosphoreum을 고정화하기 위한 Carboxymethylcellulose Sodium Salt [CMC] 담체의 이용성 연구 (Studies on the Use of Carboxymethylcellulose Sodium Salt Matrix for the Immobilization of Photobacterium phosphoreum)

  • 이용제;정성제;허문석;전억한
    • KSBB Journal
    • /
    • 제15권1호
    • /
    • pp.49-54
    • /
    • 2000
  • 1.0%(w/v)의 CMC 담체는 고정화를 유지할 수 있는 점도를 가지며 0.1 M 이하의 양이온과 이온가교결합을 할 수 있는 농도이다. Luminometer tube내의 시료에 유동을 최소화함으로써 산소의 공급을 일정하게 하여 P. phosphoreum을 고정화 30분 후 bioluminescence intensity가 안정되어 바로 측정할 수 있는 장점을 가지고 있었다. 1.0%(w/v) CMC담체는 pH 6.92로 최적조건인 pH 7.0에 근접했으며, 발광기작에 필요한 산소전달(oxygen transfer)이 1.5%(w/v)~3.0%(w/v) CMC 담체보다 뛰어나 Bioluminescence intensity의 안정성을 부여하였다. Cr-화합물인 $Na_{2}CrO_{4}$, $K_{2}CrO_{4}$, $CrO_{3}$, CrK$(SO_4)_{2}$$CrCl_{3}$의 CMC담체에 대한 민감도는 $\gamma$값을 이용해서 $EC_{50}$값으로 나타내었을 때 $Na_{2}CrO_{4}$, $K_{2}CrO_{4}$, CrK$(SO_4)_{2}$$CrCl_{3}$$EC_{50}$값이 1.0%(w/v)CMC에서는 5.4~16.3 g/L으로 1.5%(w/v)~3.0%(w/v) CMC에서는 6.2~555.9 g/L의 범위로 나타났다. 이것은 1.0%(w/v) CMC가 낮은 독성 농도에서 bioluminescence intensity가 50% 감소함을 알 수 있고, 상관계수($R^2$)가 0.911~0.990 으로 높게 산출되었다. 따라서 1.0%(w/v) CMC 담체가 P. phosphoreum의 biolumincsene에 안정성을 주었으며, 독성물질에 가장 민감하다는 것을 알 수 있었다.

  • PDF

대기 중 휘발성유기오염물질의 환경, 개인 및 인체 노출의 상관성 연구 (A Correlation Study between the Environmental, Personal Exposures and Biomarkers for Volatile Organic Compounds)

  • 조성준;신동천;정용
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권3호
    • /
    • pp.197-205
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health problem throughout the world. Many important questions remain to be addressed in assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in the analytical determination of VOCs. Personal exposure measurements are needed to evaluate the relationship between microenvironmental concentrations and actual exposures. It is also important to investigate exposure frequency, duration, and intensity, as well as personal exposure characteristics. In addition to air monitoring, biological monitoring may contribute significantly to risk assessment by allowing estimation of absorbed doses, rather than just the external exposure concentrations, which are evaluated by environmental and personal monitoring. This study was conducted to establish the analytic procedure of VOCs in air, blood, urine and exhaled breath and to evaluate the relationships among these environmental media. The subjects of this study were selected because they are occupationally exposed to high levels of VOCs. Environmental, personal, blood, urine and exhalation samples were collected. Purge & trap, thermal desorber, gas chromatography and mass selective detector were used to analyze the collected samples. Analytical procedures were validated with the“break through test”, 'quot;recovery test for storage and transportation”,“method detection limit test”and“inter-laboratory QA/QC study”. Assessment of halogenated compounds indicted that they were significantly correlated to each other (p value < 0.01). In a similar manner, aromatic compounds were also correlated, except in urine sample. Linear regression was used to evaluate the relationships between personal exposures and environmental concentrations. These relationships for aromatic and halogenated are as follows: Halogen $s_{personal}$ = 3.875+0.068Halogen $s_{environmet}$, ($R^2$= .930) Aromatic $s_{personal}$ = 34217.757-31.266Aromatic $s_{environmet}$, ($R^2$= .821) Multiple regression was used to evaluate the relationship between exposures and various exposure deter-minants including, gender, duration of employment, and smoking history. The results of the regression model-ins for halogens in blood and aromatics in urine are as follows: Halogen $s_{blood}$ = 8.181+0.246Halogen $s_{personal}$+3.975Gender ($R^2$= .925), Aromatic $s_{urine}$ = 249.565+0.135Aromatic $s_{personal}$ -5.651 D.S ($R^2$ = .735), In conclusion, we have established analytic procedures for VOC measurement in biological and environmental samples and have presented data demonstrating relationships between VOCs levels in biological media and environmental samples. Abbreviation GC/MS, Gas Chromatography/Mass Spectrometer; VOCs, Volatile Organic Compounds; OVM, Organic Vapor Monitor; TO, Toxic Organicsapor Monitor; TO, Toxic Organics.

HPLC를 이용한 숙성치즈로부터 바이오제닉 아민 분석법 개발 (HPLC-based Analysis of Biogenic Amines in Aging-Cheese)

  • 박종혁;이상천;문혜정;오전희;송기봉
    • Journal of Dairy Science and Biotechnology
    • /
    • 제34권3호
    • /
    • pp.187-191
    • /
    • 2016
  • 본 연구는 국내산 숙성치즈의 바이오제닉 아민 함량 분석을 위한 기초연구로 HPLC 분석법을 이용한 숙성치즈의 바이오제닉 아민 함량 분석법을 검토하였다. 본 연구에서 사용된 바이오제닉 아민의 종류는 Histamine dihydrochloride, Tyramine hydrochloride, ${\beta}$-phenylethylamine hydrochloride, Putrescine dihydrochloride, Cadaverine, Spermidine, Tryptamine hydrochloride, Ethanolamine hydrochloride 및 Butylamine로 총 9종이었으며, 분석항목은 직선성, 검출한계, 정량한계 및 회수율을 측정하였다. 각각의 바이오제닉 아민의 직선성은 모두 r = 0.99 이상으로 측정되어 양호하게 분석되었고, 검출한계는 각각 3.7, 3.4, 3.4, 4.0, 3.4, 3.4, 3.5, 4.1 및 3.4 ppm, 정량한계는 11.3, 10.4, 10.3, 12.2, 10.4, 10.5, 10.7, 12.5 및 10.4 ppm으로 나타났으며, 회수율은 112, 104, 93, 108, 91, 102, 101 및 92%로 나타났다. 따라서 본 연구를 통하여 바이오제닉 아민 9종에 대한 직선성, 검출한계, 정량한계 및 회수율을 측정한 결과, 모두 만족스러운 결과를 나타냈으며, 숙성치즈의 바이오제닉 아민에 대한 기초자료로 사용될 수 있을 것으로 기대된다.

고성능 박층 크로마토그래프를 이용한 실데나필과 그 유사 물질의 정량에 관한 연구 (Determination of Sildenafil and Its Related Substances Using High Performance Thin Layer Chromatography)

  • 최현철;강신정;윤미옥;박상애;김호정;위세승;김자연;차기원
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.32-38
    • /
    • 2003
  • 고성능박층크로마토그래프 (HPTLC : high performance thin layer chromatography)를 이용하여 실데나필과 그 유사체인 바데나필, 호모실데나필, 타다나필등을 신속하고 정확하게 분리정량하는 방법을 연구하였다. 실데나필 및 유사실데나필에 대한 최적의 분리조건과 각 성분의 고유한 UV스펙트럼을 얻었다. 각 성분의 검정선의 직선범위는 4성분에 대하여 약 $1.0{\sim}56.5{\mu}g/mL$이며, 상관계수($r^2$)은 모두 0.999이상 이었다. 정량한계는 약 $1.0{\sim}2.3{\mu}g/mL$, 검출한계는 약 $0.8{\sim}1.8{\mu}g/mL$이었으며, 정밀성을 시험한 결과 분산계수 (C.V.)가 2.5% 이하였다. 동 시험법으로 건강보조식품중 함유되어 있는 실데나필 및 그 유사체의 확인 및 함유량을 매우 신속하게 측정할 수 있었다.

TCS 링크통행시간을 이용한 고속도로 경로통행시간 추정 (A Path Travel Time Estimation Study on Expressways using TCS Link Travel Times)

  • 이현석;전경수
    • 대한교통학회지
    • /
    • 제27권5호
    • /
    • pp.209-221
    • /
    • 2009
  • 운전자가 원하는 통행시간 예측 정보를 제공하기 위해서는 이미 알고 있는 교통상황 하에서의 통행시간 추정이 선행되어야 한다. 그러나 현재 고속도로에 적용되고 있는 지점검지기에 의한 통행시간 추정 방법은 신뢰성 있는 통행시간을 산출하기에는 한계가 있다. 따라서 본 연구에서는 신뢰성 있는 예측정보를 제공하기 위한 기반 결과로서 고속도로 경로의 기 종점 영업소 간에서 실제 소요된 통행시간의 추정에 주안점을 두었다. 통행시간 추정시 교통정보의 활용도 측면에서 매우 유용하면서도 풍부한 고속도로 통행료 수납시스템 (Toll Collection System, TCS) 자료를 이용하였다. 경로통행시간 추정모형에서는 경로 내의 링크통행시간을 조합하여 고속도로의 경로통행시간을 추정하였다. TCS 자료가 결측 된 경우에는 통행시간의 증가패턴을 분석하여 선형보간법을 통해 이전주기의 TCS 통행시간을 참조하였다. 결측이 장기간 지속되거나 통행시간의 변동이 심한 전이시간대에는 VDS 시공도에 의한 동적인 통행시간을 추정하였다. 본 연구에서 제안한 모형을 통해 추정된 경로의 통행시간은 경로를 직접 통행한 차량들의 통행시간과 통계적으로 차이가 없음이 검증되었다. 제안모형은 동일 출발 시간대에서는 통행시간의 편차가 심하고 전 후 시간대에서는 통행시간 대푯값의 변화 패턴이 불규칙한 장거리 구간에 대해 신뢰성 있는 통행시간을 추정할 수 있었다. 본 연구에서 추정된 통행시간은 교통 상황의 성능 지표 및 실시간 통행시간 예측 분야에 활용될 수 있을 것으로 기대된다.

중성운반체를 이용한 K+ 이온선택성 PVC막 전극 (K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers)

  • 김용렬;조경섭;강안수
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.734-741
    • /
    • 1998
  • 본 연구에서는 전극전위 분석법을 사용하여 중성운반체로 dibenzo-18-crown-6(D18Cr6)와 valinomycin(Val)을 이용하여 $K^+$ 이온선택성 PVC막 전극의 막과 용액계면에서의 전극특성을 검토하였다. PVC막에서 감응물질(운반체)에 기본전해질의 혼입 (doping)여부, 감응물질의 종류와 함량, 가소제, 막두께 및 이온의 활동도변화에 따른 전극의 기울기, 선형응답범위 한계측정농도 및 방해이온에 따른 선택계수 등 전극특성을 검토하였다. 중성운반체로 D18Cr6, Val을 $K^+$ 이온으로 착체형성하여 사용하였고, 가소제로 dibutylphthalate(DBP), dioctyl sebacate(DOS) 및 dibutyl sebacate(DBS)를, 혼입제인 기본전해질로 potassium tetraphenylborate (KTPB) 및 용매로 THF를 지지체로 PVC를 이용하여 막을 제조하였다. 운반체의 최적 함량은 D18Cr6와 Val의 경우 3.23 wt %이었고, 가소제는 DBP가 가장 적절한 가소제이었다. 막두께에 대한 영향은 최적 막두께 이상에서는 막두께가 얇아질수록 전극특성이 좋아졌으나, 막두께가 이 이하로 얇아지면 운반체의 용출, 막의 강도 등이 작용하여 전극특성이 나빠짐을 알 수 있었다. D18Cr6의 경우 $K^+$ 이온에 대한 혼합용액법에 의한 선택계수 서열은 다음과 같았다: $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

시판 호상 요구르트의 품질 특성과 항산화 활성 (Quality characteristics and antioxidant capacities of Korean commercial yogurt)

  • 노영희;장아순;표영희
    • 한국식품과학회지
    • /
    • 제52권2호
    • /
    • pp.113-118
    • /
    • 2020
  • 국내에서 시판되는 20종의 호상 요구르트의 품질 특성은 pH 4.05-4.51, 적정산도 0.80-1.45%, 생균수 6.65-9.39 log CFU/g 으로 측정되어 일반적인 호상 요구르트의 품질기준에 적합한 것으로 나타났다. 총 페놀함량은 생크림 요거트(D-2)가 0.71 mg GAE/g으로 가장 낮은 반면, 블루베리(E-2)와 딸기 시럽(A-2, C-1, B-1)이 첨가된 요구르트(2.30-2.92 mg GAE/g)가 가장 높게 측정되었다. 시판 호상 요구르트에 함유된 lactic acid의 함량은 20.38-54.42 mg으로 측정되었으며, 총 유기산 함량의 82.9%를 차지하여 주요 유기산 성분으로 나타났다. 생균수와 젖산 및 총 유기산의 함량이 가장 높은 시료는 그릭 요거트(G-1)로 나타났다. DPPH와 ABTS 라디컬 소거활성으로 측정된 항산화 활성이 가장 높은 시료는 딸기시럽이 첨가된 A-2와 B-1이었으며, 가장 낮은 시료는 플레인 소프트 요거트 F-1이었다. 이들 항산화 측정법과 시료에 함유된 총 페놀함량과의 상관관계는 평균 r=0.4574로 나타나, 호상 요구르트의 항산화 활성은 자체 내 함유된 총 페놀성분의 농도와 밀접한 상관성을 보여 주었다. 따라서 본 연구의 결과는, 소비자 측면에서 항산화 활성과 probiotics의 효능을 동시에 지향하는 요구르트 제품을 선택하고자 할 때 유익한 정보로 활용될 수 있다.