• Title/Summary/Keyword: Linear Scanning

Search Result 402, Processing Time 0.024 seconds

Eliminating Voids in Direct Bonded Si/Si3N4‖SiO2/Si Wafer Pairs Using a Fast Linear Annealing (직접접합 실리콘/실리콘질화막//실리콘산화막/실리콘 기판쌍의 선형가열에 의한 보이드 결함 제거)

  • Jung Youngsoon;Song Ohsung;Kim Dugjoong;Joo Youngcheol
    • Korean Journal of Materials Research
    • /
    • v.14 no.5
    • /
    • pp.315-321
    • /
    • 2004
  • The void evolution in direct bonding process of $Si/Si_3$$N_4$$SiO_2$/Si silicon wafer pairs has been investigated with an infrared camera. The voids that formed in the premating process grew in the conventional furnace annealing process at a temperature of $600^{\circ}C$. The voids are never shrunken even with the additional annealing process at the higher temperatures. We observed that the voids became smaller and disappeared with sequential scanning by our newly proposed fast linear annealing(FLA). FLA irradiates the focused line-shape halogen light on the surface while wafer moves from one edge to the other. We also propose the void shrinking mechanism in FLA with the finite differential method (FDM). Our results imply that we may eliminate the voids and enhance the yield for the direct bonding of wafer pairs by employing FLA.

Determination of Ag(I) at a Chemically Modified Electrode Based on 2-Imino-cyclopentane-dithiocarboxylic Acid

  • Jeong-Sik Yeom;Mi-Sook Won;Sung-Nak Choi;Yoon-Bo Shim
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.200-205
    • /
    • 1990
  • Chemically modified electrodes(CMEs), based on 2-imino-1-cyclopentane-dithiocarboxylic acid (icdc) containing carbon paste, have been characterized using cyclic voltammetric techniques. Ag(I) was chemically deposited on the CMEs, and voltammograms were obtained with the electrode in a separate buffer solution. The CME surface can be regenerated with exposure to acid and reused for deposition. In 10 deposition/measurement/regenerate cycles, the linear response have been reproduced up to $1{\times}10^{-6}$ M in linear sweep voltammetry and 1${\times}$10-8 M in differential pulse voltammetry with relative standard deviation of 5.2% and 12.4%, respectiveiy. The sensitivity increased with deposition time and scanning rate, and detection limit was $1{\times}10^{-7}M\;and\;1{\times}10^{-9}M$ at 20 minutes deposition in the linear sweep voltammetry and differential pulse voltammetry, respectively. The presence of some metal ions does not influence the silver ion response. Satisfactory results were obtained for the analysis of the silver ion for a variety of reference materials without interference of Hg ion at the condition of pH = 5-6.

Three dimensional reconstruction and measurement of underwater spent fuel assemblies

  • Jianping Zhao;Shengbo He;Li Yang;Chang Feng;Guoqiang Wu;Gen Cai
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3709-3715
    • /
    • 2023
  • It is an important work to measure the dimensions of underwater spent fuel assemblies in the nuclear power industry during the overhaul, to judging whether the spent fuel assemblies can continue to be used. In this paper, a three dimensional reconstruction method for underwater spent fuel assemblies of nuclear reactor based on linear structured light is proposed, and the topography and size measurement was carried out based on the reconstructed 3D model. Multiple linear structured light sensors are used to obtain contour size data, and the shape data of the whole spent fuel assembly can be collected by one-dimensional scanning motion. In this paper, we also presented a corrected model to correct the measurement error introduced by lead-glass and water is corrected. Then, we set up an underwater measurement system for spent fuel assembly based on this method. Finally, an underwater measurement experiment is carried out to verify the 3D reconstruction ability and measurement ability of the system, and the measurement error is less than ±0.05 mm.

Identifying Puddles based on Intensity Measurement using LiDAR

  • Minyoung Lee;Ji-Chul Kim;Moo Hyun Cha;Hanmin Lee;Sooyong Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.267-274
    • /
    • 2023
  • LiDAR, one of the most important sensing methods used in mobile robots and cars with assistive/autonomous driving functions, is used to locate surrounding obstacles or to build maps. For real-time path generation, the detection of potholes or puddles on the driving surface is crucial. To achieve this, we used the coordinates of the reflection points provided by LiDAR as well as the intensity information to classify water areas, which was achieved by applying a linear regression method to the intensity distribution. The rationale for using the LiDAR index as an input variable for linear regression is presented, and we demonstrated that it is not affected by errors in the distance measurement value. Because of LiDAR vertical scanning, if the reflective surface is not uniform, it is divided into different groups according to the intensity distribution, and a mathematical basis for this is presented. Through experiments in an outdoor driving area, we could distinguish between flat ground, potholes, and puddles, and kinematic analysis was performed to calculate the maximum width that could be crossed for a given vehicle body size and wheel radius.

INFLUENCE OF A FUNCTIONAL LOADING TIME ON BONE FORMATION AROUND OSSEOINTEGRATED TITANIUM IMPLANTS IN ADULT DOGS (성견에서 골유착성 타이타늄 임프란트의 기능적 노출 시기가 주위의 골형성에 미치는 영향)

  • Yang Ja-Ho;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.55-74
    • /
    • 1991
  • The purpose of this study was to investigate the influence of early functional load around osseointegrated titanium implants. 24 titanium plasma spray coated implants (ITI HS-type) were placed into the previously extracted site in the mandible of six adult dogs. The implants were divided into three groups : the control group was the implants without abutment during the experimental period; the experimental group I was loaded by connecting the contoured abutment after 6 weeks of healing; the experimental group II was loaded after 12 weeks of healing: and the mandibular second premolar and surrounding tissues were selected for natural tooth group to compare the implanted group. All dogs were injected intravenously tetracycline, alizarin red S, and calcein for bone labeling. After the experimental period of 18 weeks, the dogs were sacrificed and longitudinal sections of the bone-implant interface were cut and observed using light microscope, scanning electron microscope, and fluorescence microscope. The results of the study were as follows: 1. Light and scanning electron microscopically, all implant surfaces were well contact with bone tissue at the cortical layer, but some areas of cancellous bone were not contact directly. 2. Fluorescence microscopically, number and size of the new secondary osteons around the implant were increased than those of the natural tooth. 3. Fluorescence microscopically, linear and concentrical fluorescence was observed at or near the surface of all implants, and the bone formation and remodeling of the implants loaded after 6 week of healing were great, and unloaded implants were worst. 4. Fluorescence microscopically, endosteal bone formation was greater than periosteal bone formation at or near the implants. 5. Fluorescence microscopically, number and size of linear and concentric fluorescence was increased at the lingual side than the buccal side of the loaded implants. The result of the study indicate the possibility of the early load to the implant via a prosthesis.

  • PDF

The Successive Complex Formation of Trivalent Lanthanide Ions with Ionophore ETH4120 at the Liquid/Liquid Interface (액체/액체계면에서 삼가 란탄족원소 이온과 중성담체(ETH4120)의 연속적인 착물형성 연구)

  • Choi, In Kyu;Yu, Zemu;Yeon, Jei Won;Chun, Kwan Sik;Kim, Won Ho;Eom, Tae Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.161-166
    • /
    • 1999
  • Transfer of lanthanide ions across the liquid/liquid interface facilitated by ionopore ETH4120 has been studied by using cyclic voltammetry (CV) and chronopotentiometry with cyclic linear current-scanning (CPCLCS) under the condition where the concentration of ETH4120 in nitrobenzene was much smaller than the concentration of lanthanide ions in aqueous solution. One cathodic current peak (transfer from aqueous to nitrobenzene phase) and two anodic current waves (transfer from nitrobenzene to aqueous phase) were observed. The cathodic wave was due to the formation of 1:1 (metal:ligand) complex and two anodic waves showed successive formation of 1:2 and 1:3 complexes in nitrobenzene solution. But there was no cathodic wave corresponding to two anodic waves. The ion transfer mechanism has also been discussed.

  • PDF

Studies on Gelatinization Characteristics of Some Starches by Differential Scanning Calorimetry (DSC에 의한 전분의 호화 특성에 관한 연구)

  • Kong, Jai-Yul;Kim, Min-Yong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.17 no.2
    • /
    • pp.144-148
    • /
    • 1988
  • Differential scanning calorimerty(DSC) was used to study gelatinization phenomena of defatted rice, corn, wheat, potato starch and nondefatted rice and wheat starch at heating rate $5{\sim}15^{\circ}C/min$. Gelatinization temperature of defatted rice and wheat starch indicated $4{\sim}5^{\circ}C$ lower temperature than nondefatted starch. More rapid heating rate resulted in a increasing of the gelatinization enthalpy for various starches. A linear relation was observed between water content, heating rate and gelatinization temperature. From the linear relationship existing between water content and gelatinization enthalpy, minimum water content for the gelatinization were 41, 38, 33 and 30% of rice, potato, wheat and corn starch, respectively.

  • PDF

Evolutionary Computation-based Hybird Clustring Technique for Manufacuring Time Series Data (제조 시계열 데이터를 위한 진화 연산 기반의 하이브리드 클러스터링 기법)

  • Oh, Sanghoun;Ahn, Chang Wook
    • Smart Media Journal
    • /
    • v.10 no.3
    • /
    • pp.23-30
    • /
    • 2021
  • Although the manufacturing time series data clustering technique is an important grouping solution in the field of detecting and improving manufacturing large data-based equipment and process defects, it has a disadvantage of low accuracy when applying the existing static data target clustering technique to time series data. In this paper, an evolutionary computation-based time series cluster analysis approach is presented to improve the coherence of existing clustering techniques. To this end, first, the image shape resulting from the manufacturing process is converted into one-dimensional time series data using linear scanning, and the optimal sub-clusters for hierarchical cluster analysis and split cluster analysis are derived based on the Pearson distance metric as the target of the transformation data. Finally, by using a genetic algorithm, an optimal cluster combination with minimal similarity is derived for the two cluster analysis results. And the performance superiority of the proposed clustering is verified by comparing the performance with the existing clustering technique for the actual manufacturing process image.

Mechanism of Tungsten Recovery from Spent Cemented Carbide by Molten Salt Electrodeposition

  • Hongxuan Xing;Zhen Li;Enrui Feng;Xiaomin Wang;Hongguang Kang;Yiyong Wang;Hui Jin;Jidong Li
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.75-84
    • /
    • 2023
  • The accumulation of spent carbide (YG8), not only pollutes the environment but also causes waste of tungsten, cobalt and other rare metal resources. To better address this issue, we proposed a combined electrochemical separation process of low-temperature aqueous solution and high-temperature molten salt for tungsten and cobalt. H2WO4 was obtained from spent carbide in an aqueous solution, and we calcined it to obtain WO3, which was used as a raw material to obtain tungsten by using molten salt electrodeposition. The influence of the current efficiency and the electrochemical behavior of the discharge precipitation of W(VI) were also studied. The calcination results showed that the morphology of WO3 was regular and there were no other impurities. The maximum current efficiency of 82.91% was achieved in a series of electrodeposition experiments. According to XRD and SEM analysis, the recovered product was high purity tungsten, which belongs to the simple cubic crystal system. In the W(VI) reduction mechanism experiments, the electrochemical process of W(VI) in NaCl-Na2WO4-WO3 molten salt was investigated using linear scanning voltammetry (LSV) and chronoamperometry in a three-electrode system. The LSV showed that W(VI) was reduced at the cathode in two steps and the electrode reaction was controlled by diffusion. The fitting results of chronoamperometry showed that the nucleation mechanism of W(VI) was an instantaneous nucleation mode, and the diffusion coefficient was 7.379×10-10 cm2·s-1.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.