• Title/Summary/Keyword: Linear Generator

Search Result 412, Processing Time 0.043 seconds

Development of Tubular Type Linear Generator for Free-Piston Engine (Free-Piston 엔진용 원통형 선형 발전기의 개발)

  • Kim, Dong-Hyun;Lim, Jae-Won;Choi, Ho-Yong;Hong, Sun-Ki;Lim, Hee-Su;Oh, Si-Doek;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.874-875
    • /
    • 2008
  • 본 논문에서는 Free-Piston 엔진용 원통형 선형 발전기의 개발에 대하여 기술한다. 발전기의 주요 특성인 역기전력과 디텐트력은 유한요소법을 통하여 해석되었고, 극 피치조정법을 사용하여 기기의 운전에 악영향을 미치는 디텐트력을 저감하였다. 제안된 설계안은 실제 제작되었고 실험을 통해 검증되었다.

  • PDF

Accuracy evaluation of the device to validate spirometer performance (진단폐활량계 성능검증을 위한 장치의 정확도 평가)

  • Lee, In-kwang;Park, Mi-Jung;Kim, Kyoung-Oak;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1429-1430
    • /
    • 2015
  • The present study developed an air flow generator system with standard syringes usually adapted for spirometer calibration. It consisted of servo-motor, driver, linear robot, and controller operating as a whole integrated system capable of generating air flows at different speeds on two identical 3L syringes. Experiments demonstrated high accuracy in both flow and volume generation as required such that relative errors were approximately 2.1% and 0.5%, respectively.

  • PDF

VIABILITY FOR SEMILINEAR DIFFERENTIAL EQUATIONS OF RETARDED TYPE

  • Dong, Qixiang;Li, Gang
    • Bulletin of the Korean Mathematical Society
    • /
    • v.44 no.4
    • /
    • pp.731-742
    • /
    • 2007
  • Let X be a Banach space, $A:D(A){\subset}X{\rightarrow}X$ the generator of a compact $C_0-semigroup\;S(t):X{\rightarrow}X,\;t{\geq}0$, D a locally closed subset in X, and $f:(a,b){\times}C([-q,0];X){\rightarrow}X$ a function of Caratheodory type. The main result of this paper is that a necessary and sufficient condition in order that D be a viable domain of the semi linear differential equation of retarded type $$u#(t)=Au(t)+f(t,u_t),\;t{\in}[t_0,\;t_0+T],{u_t}_0={\phi}{\in}C([-q,0];X)$$ is the tangency condition $$\limits_{h{\downarrow}0}^{lim\;inf\;h^{-1}d(S(h)v(0)+hf(t,v);D)=0}$$ for almost every $t{\in}(a,b)$ and every $v{\in}C([-q,0];X)\;with\;v(0){\in}D$.

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.400-406
    • /
    • 2010
  • This paper deals with parameter tuning of the Power System Stabilizer (PSS) for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations.

A New Dynamic Residual Generator for Process Fault Detection (프로세스고장검출을 위한 새로운 잔차발생기구)

  • 이기상;이상문
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.575-582
    • /
    • 2003
  • A new FDOs (fault diagnostic observers) and the residual generation schemes using the FDOs are suggested for the process fault detection and isolation of linear (control) systems. The design method of the FDO is described, first, for the full measurement systems. Then it is extended for the systems with unmeasurable state variables. An unknown input observer is proposed and applied for the extension. The size of the observer bank may be the smallest, specially in full measurement systems, because the order of the proposed FDO is very low. In spite of the simplicity, the scheme provides the same information for the detection and isolation of the anticipated faults as the conventional multiple observer based schemes. The residuals may be structured so that fault isolation can be performed by pre-selected logic. An FDIS using the proposed scheme is constructed for the model of the four-tank system. Simulation results show the practical feasibility of the proposed scheme.

Study on the Transient Phenomenon Simulation of Wind Power Generation System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전시스템의 과도현상 시뮬레이션에 관한 연구)

  • Han, Sang-Geun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.309-312
    • /
    • 2002
  • For the purpose of more effective simulation of the utility interactive WPGS(Wind Power Generation System) the SWRW (Simulation method for WPGS using Real Weather condition) is used in this paper, in which those of three topics for the WPGS simulation. user-friendly method, applicability to grid-connection and the utilization of the real weather conditions, are satisfied. The simulation of the WPGS using the real weather condition including components modeling of wind turbine system is achieved by introducing the interface method of a non-linear external parameter and FORTRAN using PSCAD/EMTDC. The simulations of steady-state and transient-state are performed effectively by the introduced simulation method. The generator output and current supplied into utility can be obtained by the steady-state simulation, and THD can be achieved by analyzing the results as well. The transient - state of the WPGS can be analyzed by the simulation results of over cut-out wind speed.

  • PDF

Design of Optimal Kinetic Energy Harvester Using Double Pendulum (이중진자를 이용한 최적의 운동에너지 하베스터 설계)

  • Lee, Chibum;Park, Hee Jae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.619-624
    • /
    • 2015
  • Owing to miniaturization and low-power electronics, mobile, implanted, and wearable devices have become the main trends of electronics during the past decade. There has been much research regarding energy harvesting to achieve battery-free or self-powered devices. The optimal design problems of a double-pendulum kinetic-energy harvester from human motion are studied in this paper. For the given form factor, the weight of the harvester, and the known human excitation, the optimal design problem is solved using a dynamic non-linear double-pendulum model and an electric generator. The average electrical power was selected as the performance index for the given time period. A double-pendulum harvester was proven to be more efficient than a single-pendulum harvester when the appropriate parameters were used.

A Study on Low Frequency Oscillations in Electric Power Systems. (전력계통의 저주파진동현상해석에 관한 연구)

  • Song, Kil-Yeong;Kwon, Sae-Hyuk;Chang, Bang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.870-873
    • /
    • 1988
  • AESOPS computer program is designed to find those eigenvalues of a linear dynamic system model which most strongly characterize oscillations between generator rotors. The low frequency oscillation actually occurred in October, 1986 in Korean Electric Power Corporation (KEPCO) System. 28 oscillation modes are identified through computer runs and two of them are calculated unstable in the case of the start of a pumped-storage unit. This program is considered to complement the conventional PSS/E stability program for the stability study of KEPCO system.

  • PDF

Identification of Optimum Sites for Power System Controller using Normal Forms of Vector Field (벡터계 정규 형식을 이용한 전력시스템 제어기 설치 위치 선정)

  • 장길수;이인수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.227-233
    • /
    • 2004
  • In stressed power system due to the presence of increased nonlinearity and the existence of nonlinear modal interactions. there exist some limitations to the use of conventional linear system theory to identify the optimum sites for a controller. This paper suggests an approach based on the method of normal forms to identify the optimum sites for controllers with incorporating the nonlinear interaction . In this paper, nonlinear participation factors and coupling factors are proposed as measures of the nonlinear interactions, and identification procedure of optimum sites for a controller is also proposed. The proposed procedure is applied to the 10-generator New England System and the KEPCO System in the year of 2010, and the results illustrate its capabilities.

Detent force reduction in tubular type linear generator for free piston engine (Free-piston 엔진용 원통형 선형 발전기의 디텐트력 저감 설계)

  • Kim, Young-Wook;Lim, Jae-Won;Choi, Ho-Yong;Hong, Sun-Ki;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.833-834
    • /
    • 2006
  • 디텐트력은 철심형 영구 자석 전기기기의 구조상 피할 수 없는 기기 특성이며 원통형 선형발전기에서도 기기의 정상적인 동작을 방해하는 요인으로 작용한다. 특히 정격 외부 입력이 작은 경우 디텐트력은 기기의 성능에 크게 영향을 미칠 수 있으며 이를 저감할 수 있는 설계가 필수적이다. 본 논문에서는 여러 가지의 디텐트력 저감법 중 이동자의 극 피치 조정을 통해 디텐트력을 저감하고자 하였다. 극피치의 변화는 디텐트력 외에도 역기전력 파형에 영향을 주게 되므로, 기기의 목표 성능을 만족하기 위해서는 디텐트력과 역기전력을 함께 고려하여야 한다. 제안된 설계안은 유한요소법을 이용하여 해석되었으며 이를 통해 얻어진 결과를 고려하여 최종 모델을 도출하였다.

  • PDF