• 제목/요약/키워드: Linear Fractional Transformation Method

검색결과 13건 처리시간 0.025초

선형 행렬부등식과 분해법을 이용한 퍼지제어기 설계 (Design of LFT-Based T-S Fuzzy Controller for Model-Following using LMIs)

  • 손홍엽;이희진;조영완;김은태;박민용
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 추계학술대회 학술발표 논문집
    • /
    • pp.123-128
    • /
    • 1998
  • This paper proposes design of LFT-based fuzzy controllers for model-following, which are better than the previous input-output linearization controllers, which are not able to follow the model system states and which do not guarantee the stability of all states. The method proposed in this paper provides a LFT-based Takagi-Sugeno(T-S) fuzzy controller with guaranteed stability and model-following via the following steps: First, using LFT(Linear Fractional Transformation) and T-S fuzzy model, controllers, are obtained. Next, error dynamics are obtained for model-following, and errors go to 0(zero). Finally, a T-s fuzzy controller that can stabilizxe the system with the requirement on the control input satisfied is obtained by solving the LMIs with the MATLAB LMI Control Toolbox and a model-following controller is obtained. Simulations are performed for the LFT-based T-S fuzzy controller designed by the proposed method, which show better performance than the results of input-out ut linearization controller.

  • PDF

LFT Modeling and Robust Stability Analysis of Missiles with Uncertain Parameters

  • Hou, Zhen-Qian;Liang, Xiao-Geng;Wang, Wen-Zheng;Li, Rui
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.173-182
    • /
    • 2014
  • The structured singular value (${\mu}$) analysis based method has many advantages for the robust stability analysis of missiles with uncertain parameters. Nevertheless, the present linear fractional transformation (LFT) modeling process, which is the basis of ${\mu}$ analysis, is complex, and not suitable for automatic implementation; on the other hand, ${\mu}$ analysis requires a large amount of computation, which is a burden for large-scale application. A constructive procedure, which is computationally more efficient, and which may lead to a lower order realization than existing algorithms, is proposed for LFT modeling. To reduce the calculation burden, an analysis method is developed, based on skew ${\mu}$. On this basis, calculation of the supremum of ${\mu}$ over a fixed frequency range converts into a single skew ${\mu}$ value calculation. Two algorithms are given, to calculate the upper and lower bounds of skew ${\mu}$, respectively. The validity of the proposed method is verified through robust stability analysis of a missile with real uncertain parameters.

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF