• Title/Summary/Keyword: Linear Cell

Search Result 859, Processing Time 0.026 seconds

Thermoelectric/electrical characterization of electrodeposited BixTey thin films (전기도금법에 의해 전착된 BixTey 박막의 전기 및 열전 특성)

  • Yu, In-Jun;Lee, Gyu-Hwan;Kim, Yang-Do;Im, Jae-Hong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.308-308
    • /
    • 2012
  • Electrodeposition of thermoelectric materials, including binary and ternary compounds, have been attracting attentions, because its many advantages including cost-effectiveness, rapid deposition rate, and ease of control their microstructure and crystallinity by adjusting electrodeposition parameters. In this work, $Bi_xTe_y$ films were potentiostatically electrodeposited using Au/Ni(80/20 nm)/Si substrate as the working electrode in solutions consisting of 10mM $TeO_2$ and 1M $HNO_3$ where $Bi(NO_3)_3$ was varied from 2.5 to 10 mM. Prior to electrodeposition potentiostatically, linear sweep voltammograms (LSV) were acquired with a standard three-electrode cell. The $Bi_xTe_y$ films deposited using the electrolyte containing low Bi ions shows p-type conductivity, which might be attributed by the large incorporation of Te phases. Near stoichiometric $Bi_2Te_3$ thin films were obtained from electrolytes containing 5mM $Bi(NO_3)_3$. This film shows the maximum Seebeck coefficient of $-100.3{\pm}12.7{\mu}V/K$. As the increase of Bi ions in electrolytes decreases the Seebeck coefficient and resistivity. The maximum power factor of $336.2{\mu}W/m{\cdot}K^2$ was obtained from the film deposited using the solution of 7.5mM $Bi(NO_3)_3$.

  • PDF

Maxillary first molar wear: a longitudinal study of children

  • Kim, Won-Hee;Nam, Shin-Eun;Park, Young-Seok;Lee, Seung-Pyo
    • Anatomy and Cell Biology
    • /
    • v.51 no.4
    • /
    • pp.251-259
    • /
    • 2018
  • The aim of this study is to examine the correlation between tooth wear and age by quantitatively measuring maxillary first molar wear in children. A total of 150 maxillary dental models were analyzed in 30 subjects (male, 11; female, 19) with an age range of 6-14 years. Maxillary first molar wear were assessed based on area, volume and the shortest distance from the buccal occlusal plane to the central pit point (BCPH). The area and volume of the tooth cusps were measured at four different offset-plane heights (0.2, 0.4, 0.6, and 0.8 mm). Relationship between age and the amount of wear or BCPH were statistically analyzed. Correlation and regression analyses were also performed, and age estimation was obtained with linear regression analysis. Repeated measures analysis of variance (ANOVA) revealed significant differences between age and the amount of wear based on area, volume, and offset-plane height. Except age of 8 and 10, 12 and 14's 0.2-mm offset-plane-measured volume, all area and volume measurement of all ages and offset-plane height showed a significant amount of increase. Wear speeds were calculated using the BCPH. Among age and measurement variables, the correlation coefficient was strongest when the volume was measured from the 0.4-mm offset-plane. As age increases, the amount of wear, as quantified by area and volume measurements, also increases. According to this study, a regression equation that can be used for age estimation is follows: Age $(y)=0.16{\times}0.4V+0.85$ ($R^2=0.490$) using volume.

Fluid-structure interaction system predicting both internal pore pressure and outside hydrodynamic pressure

  • Hadzalic, Emina;Ibrahimbegovic, Adnan;Dolarevic, Samir
    • Coupled systems mechanics
    • /
    • v.7 no.6
    • /
    • pp.649-668
    • /
    • 2018
  • In this paper, we present a numerical model for fluid-structure interaction between structure built of porous media and acoustic fluid, which provides both pore pressure inside porous media and hydrodynamic pressures and hydrodynamic forces exerted on the upstream face of the structure in an unified manner and simplifies fluid-structure interaction problems. The first original feature of the proposed model concerns the structure built of saturated porous medium whose response is obtained with coupled discrete beam lattice model, which is based on Voronoi cell representation with cohesive links as linear elastic Timoshenko beam finite elements. The motion of the pore fluid is governed by Darcy's law, and the coupling between the solid phase and the pore fluid is introduced in the model through Biot's porous media theory. The pore pressure field is discretized with CST (Constant Strain Triangle) finite elements, which coincide with Delaunay triangles. By exploiting Hammer quadrature rule for numerical integration on CST elements, and duality property between Voronoi diagram and Delaunay triangulation, the numerical implementation of the coupling results with an additional pore pressure degree of freedom placed at each node of a Timoshenko beam finite element. The second original point of the model concerns the motion of the outside fluid which is modeled with mixed displacement/pressure based formulation. The chosen finite element representations of the structure response and the outside fluid motion ensures for the structure and fluid finite elements to be connected directly at the common nodes at the fluid-structure interface, because they share both the displacement and the pressure degrees of freedom. Numerical simulations presented in this paper show an excellent agreement between the numerically obtained results and the analytical solutions.

NADP+-Dependent Dehydrogenase SCO3486 and Cycloisomerase SCO3480: Key Enzymes for 3,6-Anhydro-ʟ-Galactose Catabolism in Streptomyces coelicolor A3(2)

  • Tsevelkhorloo, Maral;Kim, Sang Hoon;Kang, Dae-Kyung;Lee, Chang-Ro;Hong, Soon-Kwang
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.5
    • /
    • pp.756-763
    • /
    • 2021
  • Agarose is a linear polysaccharide composed of ᴅ-galactose and 3,6-anhydro-ʟ-galactose (AHG). It is a major component of the red algal cell wall and is gaining attention as an abundant marine biomass. However, the inability to ferment AHG is considered an obstacle in the large-scale use of agarose and could be addressed by understanding AHG catabolism in agarolytic microorganisms. Since AHG catabolism was uniquely confirmed in Vibrio sp. EJY3, a gram-negative marine bacterial species, we investigated AHG metabolism in Streptomyces coelicolor A3(2), an agarolytic gram-positive soil bacterium. Based on genomic data, the SCO3486 protein (492 amino acids) and the SCO3480 protein (361 amino acids) of S. coelicolor A3(2) showed identity with H2IFE7.1 (40% identity) encoding AHG dehydrogenase and H2IFX0.1 (42% identity) encoding 3,6-anhydro-ʟ-galactonate cycloisomerase, respectively, which are involved in the initial catabolism of AHG in Vibrio sp. EJY3. Thin layer chromatography and mass spectrometry of the bioconversion products catalyzed by recombinant SCO3486 and SCO3480 proteins, revealed that SCO3486 is an AHG dehydrogenase that oxidizes AHG to 3,6-anhydro-ʟ-galactonate, and SCO3480 is a 3,6-anhydro-ʟ-galactonate cycloisomerase that converts 3,6-anhydro-ʟ-galactonate to 2-keto-3-deoxygalactonate. SCO3486 showed maximum activity at pH 6.0 at 50℃, increased activity in the presence of iron ions, and activity against various aldehyde substrates, which is quite distinct from AHG-specific H2IFE7.1 in Vibrio sp. EJY3. Therefore, the catabolic pathway of AHG seems to be similar in most agar-degrading microorganisms, but the enzymes involved appear to be very diverse.

Crystal Structure of Dehydrated Partially Ag$^+$-Exchanged Zeolite A, Ag$_{4.6}Na_{7.4}$-A, Treated with Hydrogen at 350${^{\circ}C}$

  • Kim Yang;Seff Karl
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.4
    • /
    • pp.202-206
    • /
    • 1985
  • The crystal structure of The crystal structure of $Ag^+$-Exchanged Zeolite A, $Ag_{4.6}Na_{7.4}-A$, dehydrated, treated with $H_2$, and evacuated, all at $350^{\circ}C$, has been determined by single crystal x-ray diffraction methods in the cubic space group Pm3m at $24(1)^{\circ}C;$ a = $12.208(2)\AA.$ The structure was refined to the final error indices R1 = 0.088 and R2 (weighted) = 0.069 using 194 independent reflections for which II_0$ > $3{\sigma}(I_0)$. On threefold axes near the centers of 6-oxygen rings, $7.4 Na^+$ ions and $0.6 Ag^+$ ions are found. Two non-equivalent 8-ring $Ag^+$ ions are found off the 8-ring planes, each containing about $0.6 Ag^+$ ions. Three non-equivalent Ag atom positions are found in the large cavity, each containing about 0.6 Ag atoms. This crystallographic analysis may be interpreted to indicate that $0.6 (Ag_6)^{3+}$ clusters are present in each large cavity. This cluster may be viewed as a nearly linear trisilver molecule $(Ag_3)^0$ (bond lengths, 2.92 and 2.94 $\AA;$ angle, $153^{\circ})$ stabilized by the coordination of each atom to a Ag^+$ ion at 3.30, 3.33, and 3.43 $\AA$, respectively. In addition, one of the silver atoms approaches all of the 0(1) oxygens of a 4-ring at $2.76\AA.$ Altogether $7.4 Na^+$ ions, $1.8 Ag^+$ ions, and 1.8 Ag atoms are located per unit cell. The remaining $1.0 Ag^+$ ion has been reduced and has migrated out of the zeolite framework to form silver crystallites on the surface of the zeolite single crystal.

Factors associated with treatment outcomes of patients hospitalized with severe maxillofacial infections at a tertiary center

  • Kim, Hye-Won;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.3
    • /
    • pp.197-208
    • /
    • 2021
  • Objectives: The purpose of this retrospective study was to evaluate the variables associated with length of stay (LOS), hospital costs, intensive care unit (ICU) use, and treatment outcomes in patients hospitalized for maxillofacial infections at a tertiary medical center in South Korea. Materials and Methods: A retrospective chart review was conducted for patients admitted for treatment of maxillofacial infections at Dankook University Hospital from January 1, 2011 through September 30, 2020. A total of 390 patient charts were reviewed and included in the final statistical analyses. Results: Average LOS and hospital bill per patient of this study was 11.47 days, and ₩4,710,017.25 ($4,216.67), respectively. Of the 390 subjects, 97.3% were discharged routinely following complete recovery, 1.0% expired following treatment, and 0.8% were transferred to another hospital. In multivariate linear regression analyses to determine variables associated with LOS, admission year, infection side, Flynn score, deep neck infection, cardiovascular disease, admission C-reactive protein (CRP) and glucose levels, number and length of surgical interventions, tracheostomy, time elapsed from admission to first surgery, and length of ICU stay accounted for 85.8% of the variation. With regard to the total hospital bill, significantly associated variables were age, type of insurance, Flynn score, number of comorbidities, admission CRP, white blood cell, and glucose levels, admission temperature, peak temperature, surgical intervention, the length, type, and location of surgery, tracheostomy, time elapsed from admission to first surgery, and length of ICU use, which accounted for 90.4% of the variation. Age and ICU use were the only variables significantly associated with unfavorable discharge outcomes in multivariate logistic regression analysis. Conclusion: For successful and cost-effective management of maxillofacial infections, clinicians to be vigilant about the decision to admit patients with maxillofacial infections, perform appropriate surgery at an adequate time, and admit them to the ICU.

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.

Implementation of Automatic Height Adjustment System (자동 레벨 컨트롤 적재물 운반 시스템의 구현)

  • Lim, Seong-Jae;Lee, Tae-Geun;Jang, Jin-Nyeong;Ko, Ye-Eun;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.133-138
    • /
    • 2022
  • In this paper we present the system we produced to help workers at logistic centers and prevent accidents, in which they could get hurt. As a base we use the main control device, named Arduino uno, which measures the weight by using load cells. When operating with the system, by placing object on it, the system measures the weight of the object and keeps the highest point at the same height by lowering its board. This improves the convenience while placing and removing objects from the board. If the weight of the placed object is exceeding the set value the board will also lower itself to secure the safety. By using a line tracer system, the objects are being moved only on a set route with the goal to make it even more comfortable to use.

Electrochemical Characteristics and Damage Behavior in Cathode Operating Conditions of 316L Stainless Steel with Test Time and Applied Potential in Metallic Bipolar Plates for PEMFC (고분자 전해질 연료전지 양극 작동 환경에서 실험 시간 및 작동 전압 변수에 따른 316L 스테인리스강의 전기화학적 특성과 손상 거동)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.451-465
    • /
    • 2021
  • In this investigation, electrochemical characteristics and damage behavior of 316L stainless steel polymer electrolyte membrane fuel cell(PEMFC) were analyzed by potentiodynamic and potentiostatic tests in cathode operating condition of PEMFC. As the result of potentiodynamic polarization test, range of passive region was larger than range of active region. In the result of potentiostatic test, damage depth and width, pit volume, and surface roughness were increased 1.57, 1.27, 2.48, and 1.34 times, respectively, at 1.2 V compared to 0.6 V at 24 hours. Also, as a result of linear regression analysis of damage depth and width graph, trend lines of damage depth and width according to applied potentials were 16.6 and 14.3 times larger, respectively. This demonstrated that applied potential had a greater effect on pitting damage depth of 316L stainless steel. The damage tendency values were 0.329 at 6 hours and 0.633 at 24 hours with applied potentials, representing rapid growth in depth direction according to the test times and applied potentials. Scanning electron microscopy images revealed that surface of specimen exhibited clear pitting damage with test times and applied potentials, which was thought to be because a stable oxide film was formed by Cr and Mo.

A Study on the Selection of Candidates for Substances Subject to Permission Using Chemicals Ranking and Scoring (CRS) (화학물질 우선순위 선정기법(CRS)을 활용한 허가대상 후보물질 선정 연구)

  • Kim, Hyo-dong;Park, Kyo-shik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.3
    • /
    • pp.253-267
    • /
    • 2022
  • Objectives: This study was performed to check whether the CRS (Chemical Ranking and Scoring) system is appropriate as a method to determine substances as candidates for substances subject to permission and to apply this system to the selection of candidates for substances subject to permission. Methods: A risk score was obtained by multiplying the hazard score and the exposure score and then ranking them. The hazard sub-indicators are carcinogenicity, germ cell mutagenicity, reproductive toxicity, specific target organ toxicity-repeated exposure, respiratory sensitization and endocrine disrupting chemicals. Exposure sub-indicators are persistence, bioaccumulation and emission volume. Sensitivity analysis was performed for missing values. Correlation analysis and multivariable linear regression analysis were performed among hazard, exposure and risk in order to confirm that CRS was an appropriate method. Results: As a result of the sensitivity analysis on missing values, it was confirmed that the effect on the risk ranking was not sensitive. Correlation and regression analysis confirmed that exposure had a greater effect on risk than hazard. Conclusions: The CRS system, which derives a risk score using a hazard and exposure score, is judged to be appropriate as a method for the selection of preliminary of candidates for substances subject to permission. Benzene, cadmium, nickel, and cobalt were selected as priority candidates for substances subject to permission.