• Title/Summary/Keyword: Line-By-line Method

Search Result 7,523, Processing Time 0.038 seconds

Analysis and Design of Branch Line Coupler using Microstrip Lines with Overlay (덮개층이 있는 마이크로스트립 선로를 이용한 브랜치 선로 결합기 해석 및 설계)

  • 이승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.795-801
    • /
    • 2001
  • A method of miniaturizing branch line coupler is presented. The method utilizes the microstrip line with overlay(or superstrate). The frequency dependent characteristics, dispersion and characteristic impedance, of this line are obtained by Immitance method in spectral domain and Method of Line. The relevant spectral domain Green's function is given and used to obtain numerical results. The branch line couplers with overlays are designed and fabricated at 2 GHz. The experimental results show that the size of coupler with overlay(${epsilon}_r$=10.2) is 31.4 precent smaller than conventional coupler. This minimized coupler is suitable for Butler Matrix as feeder for mobile communication beam forming antenna.

  • PDF

A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter (고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터)

  • Moon, SangCheol;Chung, Bonggeun;Koo, Gwanbon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

Power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal

  • Cao, Xiaoling;Yan, Liangjun
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.251-261
    • /
    • 2018
  • With the urbanization in recent years, the power line interference noise in electromagnetic signal is increasing day by day, and has gradually become an unavoidable component of noises in magnetotelluric signal detection. Therefore, a kind of power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal is put forward in this paper. The method first uses wavelet decomposition to change single-channel signal into multi-channel signal, and then takes advantage of blind source separation principle of independent component analysis to eliminate power line interference noise. There is no need to choose the layer number of wavelet decomposition and the wavelet base of wavelet decomposition according to the observed signal. On the treatment effect, it is better than the previous power line interference removal method based on independent component analysis. Through the de-noising processing to actual magnetotelluric measuring data, it is shown that this method makes both the apparent resistivity curve near 50 Hz and the phase curve near 50 Hz become smoother and steadier than before processing, i.e., it effectively eliminates the power line interference noise.

Shallow ground treatment by a combined air booster and straight-line vacuum preloading method: A case study

  • Feng, Shuangxi;Lei, Huayang;Ding, Xiaodong;Zheng, Gang;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-141
    • /
    • 2021
  • The vacuum preloading method has been used in many countries for soil improvement and land reclamation. However, the treatment time is long and the improvement effect is poor for the straight-line vacuum preloading method. To alleviate such problems, a novel combined air booster and straight-line vacuum preloading method for shallow ground treatment is proposed in this study. Two types of traditional vacuum preloading and combined air booster and straight-line vacuum preloading tests were conducted and monitored in the field. In both tests, the depth of prefabricated vertical drains (PVDs) is 4.5m, the distance between PVDs is 0.8m, and the vacuum preloading time is 60 days. The prominent difference between the two methods is when the preloading time is 45 days, the injection pressure of 250 kPa is adopted for combined air booster and straight-line vacuum preloading test to inject air into the ground. Based on the monitoring data, this paper systematically studied the mechanical parameters, hydraulic conductivity, pore water pressure, settlement and subsoil bearing capacity, as determined by the vane shear strength, to demonstrate that the air-pressurizing system can improve the consolidation. The consolidation time decreased by 15 days, the pore water pressure decreased to 60.49%, and the settlement and vane shear strengths increased by 45.31% and 6.29%, respectively, at the surface. These results demonstrate the validity of the combined air booster and straight-line vacuum preloading method. Compared with the traditional vacuum preloading, the combined air booster and straight-line vacuum preloading method has better reinforcement effect. In addition, an estimation method for evaluating the average degree of consolidation and an empirical formula for evaluating the subsoil bearing capacity are proposed to assist in engineering decision making.

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

Determination of Yield Line Patterns On the basis of Elastic Fields (탄성해석에 기반한 항복선 형상 추정기법)

  • Song, Jong-Young;Lee, Wan-Su
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.285-292
    • /
    • 2004
  • The objective of this paper is to develop a simplified method to determine yield line patterns of reinforced concrete floor slabs based on the elastic fields. Unlike other methods mainly focused on the plasticity theory, this paper emphasizes the elastic fields, especially principal moments and maximum shears and shows a link between elasticity field and yield line patterns. General criteria on both positive and negative yield lines are suggested in terms of principal moments and maximum shear forces. The proposed method can predict starting point (or regions) of yielding and the further development of yield lines on whole structures. The yield line patterns determined by the proposed method are shown to be coincident with the classical yield line theory. Furthermore, orthotropy in reinforced concrete slab is investigated and yield line patterns for different type of flat slab with non-isotropic strip are studied broadly.

  • PDF

A novel method to specify pattern recognition of actuators for stress reduction based on Particle swarm optimization method

  • Fesharaki, Javad Jafari;Golabi, Sa'id
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.725-742
    • /
    • 2016
  • This paper is focused on stiffness ratio effect and a new method to specify the best pattern of piezoelectric patches placement around a hole in a plate under tension to reduce the stress concentration factor. To investigate the stiffness ratio effect, some different values greater and less than unity are considered. Then a python code is developed by using particle swarm optimization algorithm to specify the best locations of piezoelectric actuators around the hole for each stiffness ratio. The results show that, there is a line called "reference line" for each plate with a hole under tension, which can guide the location of actuator patches in plate to have the maximum stress concentration reduction. The reference line also specifies that actuators should be located horizontally or vertically. This reference line is located at an angle of about 65 degrees from the stress line in plate. Finally two experimental tests for two different locations of the patches with various voltages are carried out for validation of the results.

Calculating Mutual Impedance between Power-Line and Communication-Line with Earth Return Current (대지귀로 전류에 의한 전력선과 통신선의 상호임피던스 해석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.269-271
    • /
    • 2003
  • A method for calculation of mutual inductance from the parallel power-line and earth conduct to communication-line is studied in the paper. The solution for the electromagnetic field produced by an overhead power-line is derived using Maxwell's equations and treating the as a boundary value problem. Total mutual inductance from direct current and image current to communication-line is used Carson's formula for infinitely long parallel conductors.

  • PDF

Flow Analysis for an Effective Weld Line Control in Injection Molding (효과적인 웰드라인 제어를 위한 사출성형 유동해석)

  • 김현필;김용조
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.64-72
    • /
    • 2001
  • Weld line is one of serious troubles which are observed in a plastic part manufactured by a injection molding process. This is caused by many process factors, which are molding pressure, temperature, velocity, location of a injection gate, mold geometry and material properties. investigation on the effects of these process factors to the appearance of a weld line was carried out using a finite element method. Filling and packing analyses were carried out by modifying both the configuration of the injection gates and cavity thickness. Proper locations of the injection gates could be determined by considering molding pressure, temperature, velocity and frozen layer, and whereby the weld line was controled. In order to make a weak appearance of the weld line, flow velocity and flow front in a cavity were also investigated by modifying a cavity thickness. As a result, flow front was extended around the corner in the cavity by changing the flow velocity and hence the appearance of the weld line was much weakened.

  • PDF

Fast Hough Transform Using Multi-statistical Methods (다중 통계기법을 이용한 고속 하프변환)

  • Cho, Bo-Ho;Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.10
    • /
    • pp.1747-1758
    • /
    • 2016
  • In this paper, we propose a new fast Hough transform to improve the processing time and line detection of Hough transform that is widely used in various vision systems. First, for the fast processing time, we reduce the number of features by using multi-statistical methods and also reduce the dimension of angle through six separate directions. Next, for improving the line detection, we effectively detect the lines of various directions by designing the line detection method which detects line in proportion to the number of features in six separate directions. The proposed method was evaluated with previous methods and obtained the excellent results. The processing time was improved in about 20% to 50% and line detection was performed better in various directions than conventional methods with experimental images.