• 제목/요약/키워드: Line flow sensitivity

검색결과 92건 처리시간 0.023초

무효전력 손실감도를 이용한 정적 전압 안정도 해석 (Static Voltage Stability Analysis using Reactive Power Loss Sensitivity)

  • 김원겸;이복용;이상철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 전문대학교육위원 P
    • /
    • pp.52-55
    • /
    • 1999
  • In recent years, much attention has been paid to the voltage collapse phenomena. There has been reported many cases about the voltage collapse in many countries. These voltage collapse phenomena are known as the event that can occur due to reactive power deficits. This paper proposes an efficient method that can pursue the reactive power loss changes and gives the simple voltage collapse proximity indicator(VCPI) based on the reactive power loss sensitivities using optimal techniques. By comparing reactive power loss sensitivity with active power loss sensitivity, it is also proved that VCPI based on reactive power loss sensitivities is more effective. The developed VCPI is derived from the Jacobian matrix of Load Flow and the computational burden is very low and on-line implementation is possible. The proposed method is applied to a IEEE-14 bus test system and reliable and promising results are obtained.

  • PDF

수도권 순동 무효전력 확보를 위한 FACTS 협조제어 시스템 온라인 설치 (Installation of MFC(Multiple FACTS Coordinated control) On-line System for the Spinning Reserve of a Reactive Power in Metropolitan Area)

  • 장병훈;문승필;하용구;전웅재
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2131-2134
    • /
    • 2010
  • In this paper, the on-line system schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control system of FACTS devices, MFC on-line system calculates the optimal set point(Vref, Qrev) of FACTS devices using the coordinated control algorithm with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. As the test, MFC(Multiple FACTS Coordinated control) on-line system will be installed in Korea power system.

시변민감도를 반영한 On-Line SCOPF알고리듬 개발 (On-Line SCOPF Using the Time-varying Sensitivity)

  • 신영균;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.16-18
    • /
    • 2000
  • The recent movement to deregulated and competitive electricity market changes the role of Security Constrained Optimal Power Flow (SCOPF) and increases the importance for real-time computation. communication, and on-line data control. As power systems tend to be operated more closely to their ultimate ratings, more rapid updates of telemetered data and faster solutions times are becomimg necessary to better track the changes in systems. This paper presents an on-line SCOPF application exploiting the state-of-art OPF tools and corresponding interfacing technologies. The significance of the proposed mechanism is demonstrated with a case study system.

  • PDF

새로운 선로사고분배계수 알고리즘을 이용한 과부하 해소대책 (An Overload Alleviation Countermeasure using New Line Outage Distribution Factor)

  • 박규홍;정재길;강동구;김정하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.588-590
    • /
    • 1995
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads in a power system. This method utilizes network sensitivity factors which are establised from DC load flow solutions. The line outage distribution factors(LODF) are formulated using changes in network power generations to simulate the outaged line from the network. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

송전선로 과부하를 해소하기 위한 민감도에 근거한 알고리즘 연구 (A Study on an Algorithm Based on Sensitivity Method for Alleviating Overloads in Power Networks)

  • 이병하;백정명
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.96-103
    • /
    • 2008
  • 본 논문에서는 전력시스템에서의 송전선로 과부하를 해소하기 위한 민감도에 근거한 새로운 선로 스위칭 알고리즘이 제시된다. 각 선로의 임피던스 변화에 대한 과부하 선로 조류의 민감도를 통하여 과부하 선로를 해소하기 위한 여유 송전선로의 투입과 운전 중인 선로의 차단을 한꺼번에 체계적으로 수행하는 새로운 스위칭 알고리즘을 제시하고, 수많은 케이스의 스위칭 경우의 수를 대폭적으로 줄임으로써 효율적으로 선로 스위칭을 수행하여 효과적인 과부하 해소 대책을 세우는 방안을 제시한다. 제시된 민감도에 근거한 알고리즘에 따라 스위칭선로들의 순위를 결정하고 이 순위에 따라 선로 과부하가 해소될 때까지 선로 스위칭을 수행한다. 이 기법을 IEEE 39 모선 시스템에 적용하여 제시된 알고리즘의 효과를 보여준다.

조상설비를 고려한 전압안정성 여유전력의 평가에 관한 연구 (A Study for Evaluating of Voltage Stability Margin Considering Shunt Capacitor)

  • 김세영
    • 에너지공학
    • /
    • 제7권1호
    • /
    • pp.65-72
    • /
    • 1998
  • 이 논문은 극좌표이 선로조류방정식을 이용하여 전압안정성 여유전력을 평가하는 고속계산법을 제안한다. 여기서, 선로조류방정식은 상태변수 Vi, $\delta$i, Vj와 $\delta$i 그리고, 선로정수 r과 x로 구성되는데 극좌표계의 특징을 이용하면 이것은 두 개의 변수 Vi와 Vj를 가진 하나의 식이 된다. 그리고, j 모선이 조류계산에서 전압크기로 지정되는 발전기 또는 slack 모선이라면, 변수 Vi만을 가진 하나의 식 즉, {{{{ { V}`_{i } ^{2 } }}에 대한 2차 방정식으로 정식화된다. 그러므로, 전력조류다근은 간단한 계산을 통해 구할 수가 있는데 이와 같이 구해진 다근은 감도해석 또는 다근의 근접도를 통해 전압안정도를 평가할 수 가 있었다. 또한, 전압안정도 평가시에 중요한 요소인 전력용 콘덴서와 같은 조상설비를 고려하여 전압안정성 여유전력을 평가하는 방법을 개발하였다. 제안한 방법을 시험계통에 적용하여 유효성을 입증하였다.

  • PDF

초고압 직류 가공송전 후보 도체방식의 이온류 환경특성 코로나 케이지 모의시험 (Corona Cage Simulation on Environmental Characteristics Caused by the Ion flow of Candidated Conductor Bundles for HVDC Overhead Transmission)

  • 주윤노;양광호;이동일;신구용
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1791-1795
    • /
    • 2007
  • Small ions generated at conductor corona sources remain in the atmosphere until they recombine with ions of opposite polarity, attach to aerosols, or make contact with an object. Ion current density is major factor to design conductor configuration of DC overhead transmission line. Several techniques have been used to measure the ion current of HVDC overhead transmission line. In this study, the ion current density was measured by a plate electrode made of a metal flat board at DC corona cage. The sensitivity of the plate electrode is $0.156uA/m^2/V$. To obtain an useful database on corona discharge, it is necessary to do corona test on several kinds of conductor bundles. Therefore, a number of experiments were conducted on several kinds of conductor bundles. To reliably analyze ion effects, corona cage test data were obtained over a long period of time under various weather conditions and expressed as a statistical distribution. Ion current density distribution in foul weather shows a significant increase in levels over the corresponding fair weather. Based on this results, we evaluated the environmental characteristic caused by ion flow of three candidated conductor bundles.

평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

평균 양방향 튜브의 설계 최적화를 위한 FLUENT코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.180-186
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the averagebi-directional flow tube in case of water and air flow In this study, sensitivity studies have been performed to optimize the design features of the average hi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

  • PDF

전력계통(電力系統)의 상정(想定)사고(事故)에 따른 선로(線路)의 과부하(過負荷) 해소(解消) 대책(對策) (The Alleviation Countermeasures of Line Overloads Due To a Contingency Occured in Power System)

  • 정제길;노신홍;박규홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.432-436
    • /
    • 1991
  • This paper presents a new algorithm for the countermeasure to alleviate without shedding system loads the line overloads due to contingency in power system. This method for relieving by line switching is based on obtaining the line outage distribution factors - the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of same other line in the power system. These factors are made up of the elements of Bus Reactance Matrix and branch reactances. In this paper a fast algorithm and program is presented for obtaining only the required Bus Reactance elements which corresponds to a non - zero elements of Bus Admittance Matrix and elements of columns which correspond to two terminal Buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on the 6 busbar test system

  • PDF