• Title/Summary/Keyword: Line discharge

Search Result 529, Processing Time 0.026 seconds

Angio-$Seal^{TM}$ $Evolution^{TM}$ versus Manual Compression for Common Femoral Artery Puncture in Neurovascular Diagnostic Angiography: A Prospective, Non-Randomized Study

  • Chung, Joon-Ho;Lee, Dong-Woo;Kwon, Ok-Sim;Kim, Bum-Soo;Shin, Yong-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.3
    • /
    • pp.153-156
    • /
    • 2011
  • Objective : This prospective, non-randomized study compared the safety and efficacy of the Angio-$Seal^{TM}$ $Evolution^{TM}$ to that of manual compression for common femoral artery punctures in neurovascular diagnostic angiography. Methods : From June 2009 to September 2009, we performed 169 diagnostic trans-femoral cerebral angiographies, using either the Angio-$Seal^{TM}$ $Evolution^{TM}$ or manual compression to achieve hemostasis. We included 60 patients in this study, 30 in each group. We defined minor complications as those requiring no further treatment such as hematoma size less than 6 cm and bruise size less than 25 cm. Major complications were those requiring surgery of the femoral artery pseudoaneurysm and/or the second line increase of hospital stay even without further treatment. Results : Mean time to hemostasis was $0.42{\pm}0.04$ minutes for the angioseal and $15.83{\pm}1.63$ minutes for manual compression (p<0.001). Overall complication rate did not differ between the 2 groups. After the patients were fully mobile, at 24 hours, the rate of onset of new complication differed significantly between the 2 groups (p=0.032). In the angioseal group, 5 (16.7%) of the 30 patients experienced the onset of a new complication after 24 hours, including 3 (60.0%) of the 5 who experienced major complications. Conclusion : The Angio-$Seal^{TM}$ $Evolution^{TM}$ is effective at decreasing mean time to hemostasis, like other closing devices. However, it may not be effective at producing early ambulation and discharge, compared to manual compression, because delayed complications may occur significantly after 24 hours.

A Design of Wide-Bandwidth LDO Regulator with High Robustness ESD Protection Circuit

  • Cho, Han-Hee;Koo, Yong-Seo
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1673-1681
    • /
    • 2015
  • A low dropout (LDO) regulator with a wide-bandwidth is proposed in this paper. The regulator features a Human Body Model (HBM) 8kV-class high robustness ElectroStatic Discharge (ESD) protection circuit, and two error amplifiers (one with low gain and wide bandwidth, and the other with high gain and narrow bandwidth). The dual error amplifiers are located within the feedback loop of the LDO regulator, and they selectively amplify the signal according to its ripples. The proposed LDO regulator is more efficient in its regulation process because of its selective amplification according to frequency and bandwidth. Furthermore, the proposed regulator has the same gain as a conventional LDO at 62 dB with a 130 kHz-wide bandwidth, which is approximately 3.5 times that of a conventional LDO. The proposed device presents a fast response with improved load and line regulation characteristics. In addition, to prevent an increase in the area of the circuit, a body-driven fabrication technique was used for the error amplifier and the pass transistor. The proposed LDO regulator has an input voltage range of 2.5 V to 4.5 V, and it provides a load current of 100 mA in an output voltage range of 1.2 V to 4.1 V. In addition, to prevent damage in the Integrated Circuit (IC) as a result of static electricity, the reliability of IC was improved by embedding a self-produced 8 kV-class (Chip level) ESD protection circuit of a P-substrate-Triggered Silicon Controlled Rectifier (PTSCR) type with high robustness characteristics.

Simplified GIS Diagnostic SYSTEM (간이형 상시 GIS 진단장치)

  • Jeong, J.K.;Choi, Y.J.;Kang, C.I.;Jang, H.K.;Gwak, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.74-77
    • /
    • 2006
  • This research is focused on the development of GIS Diagnostic SYSTEM to prevent accidents beforehand by inspecting the internal defects of GIS (Gas Insulated Switchgear) which is a main power-facility for substations. GIS Diagnostic SYSTEM is categorized as 'Real time on-line test type' and 'Portable test type' depending on the types of testing, it uses PD(partial discharge) which mostly incurs in GIS internal defects, to inspect. As of now, mostly foreign equipments are imported for use due to the lack of the technology localization, and these are installed and operated on only some parts of highly-graded GIS power-facilities such as in 76skv or 345kv for its being expensive. Furthermore, other than foreign equipments being costly, it also has a weak point of very long unavailability in case of Diagnostic system break-down while using, because it takes a comparatively long period of corrective maintenance precesses. We have localized to develop personal real-time multi -functional GIS Diagnostic system which can test on all GIS power-facility comprehensively and economically therefore overcome all these problems mentioned above, a market expansion is expected from the decrease of price and replacing the import equipments in the future. As the equipment was developed to be Personal for the simple ways of installing and utilizing, it can be operated without any complex cable installation like other existing GIS Diagnostic system requires, therefore also decrease the cost of cable installation.

  • PDF

The Inverse Circulation System for Using Treated Waste Water as Instream Flow (하수처리수의 하천유지용수 활용을 위한 역순환시스템의 비교)

  • Kim, Gee-Hyoung;Choi, Gye-Woon;Ahn, Tae-Jin;Kim, Jin-Hong;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.863-878
    • /
    • 2003
  • In this paper, it was studied on a device for maintaining the instream flow by using treated waste water from sewage treatment plant, and discussed on using the inverse circulation system in stream for directly utilizing treated waste water as instream flow. This system is to secure insufficient discharge at upstream, as treated water is pumped from treatment plant which is located at down stream. Therefore, it will be improved water quality with simple water treatment plant, as it is composed of optimal system by consist various types of scheme for transporting. Also, influx method of transferred treated water to a stream will be improved water quality by aeration and be shown environmental friendly spaces. It was considered water quality and present using condition to use for maintenance water in stream by treated water. The guide line for application of inverse circulation system in domestic streams is suggested.

The influence of Ne-Xe gas mixture ratio on vacuum Ultraviolet and infrared line in AC-PDP

  • Oh, Phil-Y.;Cho, I.R.;Jung, Y.;Park, K.D.;Ahn, J.C.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.743-747
    • /
    • 2003
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) and infrared(IR) rays in surface discharge AC-PDP with Ne-Xe mixture gas. The influence of Ne-Xe gas-mixture ratio on resonance state $Xe^{\ast}(3P_{1})$ and exited state $Xe^{\ast}(3P_{2})$ has been investigated. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828 nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The electron temperature and plasma density have been experimentally measured from the center of sustaining electrode gap by a micro Langmuir probe in AC-PDPs. The plasma density from the center of sustaining electrode gap are shown to be maximum value of $9{\times}10^{11}cm^{-3}$, where the electron temperature is about 1.6 eV in this experiment

  • PDF

Groundwater Balance in Urban Area (도시지역의 지하수수지)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1553-1560
    • /
    • 2011
  • The study analyzes groundwater balance with regard to the water recharge and discharge which contain urbanization components in Suyeong-gu, Busan. It also verifies the reliability and accuracy improvement on the analysis of the balance. The result of the study is viewed as preliminary data which are useful to develop, utilize and manage groundwater. The average quantity of groundwater recharge is 6,014.1 $m^3$/day in the research area during the last ten year period(from 1998 to 2007). The outflow from drainage areas to rivers and coasts is 149.3 $m^3$/day, the inflow from rivers and coasts to drainage area is 439.9 $m^3$/day. The use of the water is 4,243.0 $m^3$/day. The outflow caused by subway in line No.2 and No.3 through Suyeong-gu and the one by building an underground electric complex is 1,500.0 $m^3$/day. The leakage of water works is 6514.9 $m^3$/day. The inflow and outflow of sewerage is 5082.2 $m^3$/day from groundwater to sewer. The amount of groundwater recharge, the inflow from rivers and coasts to drainage area, and the leakage of water works belong to the amount of groundwater inflow and the total amount is 12,968.9 $m^3$/day. The amount of outflow from drainage area to rivers and coasts, the use of groundwater, outflow by subway and underground electric complex tunnel and the amount of inflow of the water to sewerage belong to the amount of outflow of groundwater and the sum amount is 13,031.5 $m^3$/day. The gap between the amount of inflow and outflow of groundwater is 62.6 $m^3$/day, which is considered to reflect the trend that the short term drop in the amount of rainfall results in the amount of groundwater recharge and that the amount of outflow from drainage area to rivers and coasts decreases.

A Clinical Study of cysts on Mandible (하악골에 발생한 낭종에 관한 임상적 연구)

  • Baik, Byeong-Ju;Kim, Mi-Ra;An, Soo-Hyeon;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.678-687
    • /
    • 1997
  • Cystic lesions of the mandible are fairly common and usually a presumptive diagnosis is made readily, more often on the basis of roentgenographic appearance than by any other means. Occasionally, however, it is easy to fall into errors of diagnosis which may affect one's choice of treatment. The diagnosis in these situations are usually resolved by the histopathologic examination of material obtained by surgical exploration. The present discussion to the lesions which can be most easily confused in the roentgenographic interpretation, that is, the traumatic bone cyst, the dentigerous cyst, the radicular cyst. These lesions often grow to considerable size before they cause any subjective or objective symptoms. Less frequently, perhaps, the patient presents himself with the complaint of enlargement of the affected part, a discharge, or pain. On rare occasions the first sign is fracture through the cyst cavity. In any case, an adequate roentgenographic survey by means of extraoral films is essential. This is the primary means of diagnosis. The three lesions in mandible, reported here, resembled each other roentgenographically in that they were osteolytic lesions. The follicular and radicular cysts usually have a smooth periphery and may be surrounded by a white line. The follicular cyst, slow-growing lesions, is usually associated with an unerupted tooth. The radicular cyst, the most common type of the odontogenic cyst, is always associated with a nonvital tooth, or it may persist as a "residual" radicular cyst after the causative tooth has been extracted. The traumatic bone cyst can often be differentiated from the first two in that the periphery is less definite and is irregular. It is thought that because it does not occur in older people, the lesion is self-limiting and heals spontaneously if left alone.

  • PDF

Frequency and power stabilization of radio frequency excited CO2 laser using photoacoustic effect (광음향 효과에 의한 고주파 여기식 CO2 레이저의 주파수 및 출력 안정화)

  • Choi, Jong-Woon;Yu, Moon-Jong;Woo, Sam-Yong;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.569-574
    • /
    • 2004
  • We stabilized the frequency and power of a CW radio-frequency-excited $CO_2$ laser on the peak of the Doppler broadened gain curve using the photoacoustic effect generated from the laser itself. The condenser microphone is installed in the radio frequency discharge chamber to detect a photoacoustic signal. The photoacoustic signal is fed to a lock-in stabilizer as a reference signal for stabilization. The frequency stability is estimated to be better then 5.4${\times}$10$^{-8}$ at the P(20) line. The stabilized output variation was reduced 9.3%, compared to 100% for a free running laser.

Design and Implementation of IoT-Based Intelligent Platform for Water Level Monitoring (IoT 기반 지능형 수위 모니터링 플랫폼 설계 및 구현)

  • Park, Jihoon;Kang, Moon Seong;Song, Jung-Hun;Jun, Sang Min
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.4
    • /
    • pp.177-186
    • /
    • 2015
  • The main objective of this study was to assess the applicability of IoT (Internet of Things)-based flood management under climate change by developing intelligent water level monitoring platform based on IoT. In this study, Arduino Uno was selected as the development board, which is an open-source electronic platform. Arduino Uno was designed to connect the ultrasonic sensor, temperature sensor, and data logger shield for implementing IoT. Arduino IDE (Integrated Development Environment) was selected as the Arduino software and used to develop the intelligent algorithm to measure and calibrate the real-time water level automatically. The intelligent water level monitoring platform consists of water level measurement, temperature calibration, data calibration, stage-discharge relationship, and data logger algorithms. Water level measurement and temperature calibration algorithm corrected the bias inherent in the ultrasonic sensor. Data calibration algorithm analyzed and corrected the outliers during the measurement process. The verification of the intelligent water level measurement algorithm was performed by comparing water levels using the tape and ultrasonic sensor, which was generated by measuring water levels at regular intervals up to the maximum level. The statistics of the slope of the regression line and $R^2$ were 1.00 and 0.99, respectively which were considered acceptable. The error was 0.0575 cm. The verification of data calibration algorithm was performed by analyzing water levels containing all error codes in a time series graph. The intelligent platform developed in this study may contribute to the public IoT service, which is applicable to intelligent flood management under climate change.

Characterization of the Effects of Relative Humidity and Bed-depth on $CO_2$ Capture for Maximizing the Utilization Rate of Soda Lime Sorbent

  • Cho, Il-Hoon;Park, Guen-Il;Kim, Joon-Hyung;Hwang, Taek-Sung;Lee, Mi-Kyoung
    • Carbon letters
    • /
    • v.2 no.2
    • /
    • pp.113-119
    • /
    • 2001
  • The advanced method for $CO_2$capture is currently one of the most important environmental issues in worldwide and it is therefore necessary to have available technologies, which minimize the discharge of $CO_2$ including Carbon-14 from nuclear facilities into the atmosphere. A key aspect of this work is to provide the technically principal data required to improve a $CO_2$ removal system for the utilization of regenerative sorbent use, specifically include suggestions regarding its modified column design (parallel dual-bed assembly), stop-restart operation and the economic feasibility of sorbent use. The removal performance of soda lime and the effects of relative humidity (RH) and packing bed-depth (BD) on $CO_2$ removal were investigated. In a single-bed, it revealed that the utilization of soda lime for $CO_2$ removal at line velocity of 13 cm/sec and bed depth of 12 cm increased with the increased relative humidity up to 85%. However, in the parallel dual-bed assembly applied with the stop-restart operation, a maximum utilization rate of soda lime for $CO_2$ removal was obtained even at 55% of RH and 8 cm of BD, specifically the utilization rate of soda lime by using this $CO_2$ removal assembly was about two-fold superior to that in a single-bed.

  • PDF