• Title/Summary/Keyword: Line code

Search Result 687, Processing Time 0.024 seconds

A Case study for minimizing scale of LRT stations constructed underground (지하 경량전철의 정거장 규모조정에 관한 사례연구 (우이~신설 경량전철 중심으로))

  • Jin, Jae-Seop;Lee, Seung-Seok;O, Tae-Sang;Sin, Han-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1743-1753
    • /
    • 2011
  • Seoul Metropolitan Government has performed alternative transit system, light rail transit(LRT), for settling the problems of urban public transit system based on conventional bus service and heavy rail transit(HRT). LRT projects of total 8 lines(about 73.6km), including Ui-Sinseol line, have been planned as Build-Transfer-Operate(BTO) projects. For the first LRT, Ui-Sinseol line, however, design of structure had met standard for design of HRT, because of no domestic design code for LRT when participates of Ui-Sinseol project submitted the design proposal. This case study reports a successful example of LRT design minimizing the scale of stations designed in base of HRT code. The problems, like oversized structures compared with LRT vehicles, excessive costs for construction, had been resolved through negotiations with the participates of Ui-Sinseol line. Result suggests that present and future costs for construction and maintenance of the LRT projects in Seoul be considerably reduced in advance.

  • PDF

The study on ON-LINE and OFF-LINE systems of electronic image editing by time-code adressing method (전자 영상 편집에 있어서 time-code adressing 방식에 의한 ON-LINE, OFF-LINE system에 대한 연구)

  • BongJoKim
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.13 no.1
    • /
    • pp.93-104
    • /
    • 1995
  • Liquid crystal-polymer composite(LCPC) films promising new materials for both projection displays and vision product. LCPC films consist of a continous liquid crystal phase embedded in a three- dimensional network of polymer matrix. The liquid crystal in these LC phases can be elecrtrically switched giving rise to an opaque scattering off-stats and a transparent, non-scatting on- stats. In this work. a premixture is composed of LC, UV-curable monomer and photonitiator. LCPC films are formed by photopolymerization induced phase separation from this premixture. In conclusion, structure and electro-optical properties of LCPC films strongly depends on the selection of monomer, LC content and curing rate.

  • PDF

PDR Model : Test and fit observed data Obtained by Herschel PACS

  • Yun, Hyeong-Sik;Lee, Jeong-Eun;Lee, Seokho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2014
  • We utilized a 2-D PDR code developed by Lee et al. (2014) to explore the observed OH line fluxes toward embedded protostars. This 2-D PDR code combines self-consistently the FUV radiative transfer, gas-energetics, chemistry, and line radiative transfer. We modeled two sources, GSS30-IRS1 and Elias29, which show conspicuous line emission in the Herschel/PACS wavelength range. The physical and chemical structure for a given embedded source was derived by fitting the PACS CO line fluxes. After exploring various parameter spaces, we conclude that IR-pumping effect either by the central IR source and dust in-situ is insignificant for OH emission, unlike previous studies. We here present a possible solution for the observed OH fluxes, which require a high OH abundance and temperature at the inner-part of the UV heated cavity wall.

  • PDF

Code Coverage Measurement in Configurable Software Product Line Testing (구성가능한 소프트웨어 제품라인 시험에서 코드 커버리지 측정)

  • Han, Soobin;Lee, Jihyun;Go, Seoyeon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.7
    • /
    • pp.273-282
    • /
    • 2022
  • Testing approaches for configurable software product lines differs significantly from a single software testing, as it requires consideration of common parts used by all member products of a product line and variable parts shared by some or a single product. Test coverage is a measure of the adequacy of testing performed. Test coverage measurements are important to evaluate the adequacy of testing at the software product line level, as there can be hundreds of member products produced from configurable software product lines. This paper proposes a method for measuring code coverage at the product line level in configurable software product lines. The proposed method tests the member products of a product line after hierarchizing member products based on the inclusion relationship of the selected features, and quantifies SPL(Software Product Line) test coverage by synthesizing the test coverage of each product. As a result of applying the proposed method to 11 configurable software product line cases, we confirmed that the proposed method could quantitatively visualize how thoroughly the SPL testing was performed to help verify the adequacy of the SPL testing. In addition, we could check whether the newly performed testing for a member product covers the newly added code parts of a feature.

System Analysis for the Automated Circulation (대출업무 자동화를 위한 시스팀설계에 관한 연구)

  • Kim, Kwang-Yeong
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.4 no.1
    • /
    • pp.85-102
    • /
    • 1980
  • Accepting the necessity for maintaining the objectives of the existing circulation system, the computer-based system could be designed by the system analyst and librarians to gain a variety of improvements in the maintenance, accessibility of circulation records and more meaningful statistical records. If the terminal can be operated on-line, then this circulation data is transmitted directly to the computer, where it may update to the circulation file immediately or alternatively be kept in direct access file for updating in batch mode. on-line system in the circulation operations is "data-collection system" and "Bar-coded label system" Bar-coded label system is simple, quick, and error-free input of data. Attached to CRT terminal is a "light pen" which is hand held and will read a bar-coded label as the pen is passed over the labels (one affixed to the book itself, other carried on the borrower cards). Instantaneously the data concerning transaction is stored in the central mini-computer. It is useful, economical for us to co-operate many libraries in Korea and design borrower's ID code, book no., classification code in the Bar-coded label system by the members of the computer center and the library staff at every stage. As for book loan, the borrowers ID code, book number and classification code are scanned by the bar-code scanner or light pen and the computer decides whether to loan and store the data. The visual display unit shows the present status of a borrowers borrowing and decides whether borrower can borrow.

  • PDF

Analysis of the Boron Concentration Behavior Using LTC code During Power Maneuvering

  • Kwon, Jong-Soo;Chi, Sung-Goo;Park, Hae-Yun;Park, Seong-Hoon;Lee, Gi-Won
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.413-418
    • /
    • 1996
  • The main purpose of this paper is to develop the modified LTC code for accurate analysis of the boron concentration behavior of all components in the Nuclear Steam Supply System (NSSS). This is achieved by adapting a multi-cell mad to the existing Long Term Cooling (LTC) code. To verify the modified LTC, the simulated results were compared with the actual test results measured during YGN 4 initial criticality test. It was shown that the simulated results of this modified LTC were in good agreement with the actual test results. Also, the boron concentration behavior analysis were performed using the modified LTC code for both direct and indirect dilution/boration nude using YGN 3,4 design data. This modified LTC code can provide a valuable information in predicting boron concentration behavior during power maneuvering such as startup operation, shutdown operation and load follow operation. It is expected that the modified LTC can be applied to both on-line and off-line mode using Plant Computer System(PCS).

  • PDF

AN EXPERIMENTAL STUDY WITH SNUF AND VALIDATION OF THE MARS CODE FOR A DVI LINE BREAK LOCA IN THE APR1400

  • Lee, Keo-Hyoung;Bae, Byoung-Uhn;Kim, Yong-Soo;Yun, Byong-Jo;Chun, Ji-Han;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.691-708
    • /
    • 2009
  • In order to analyze thermal hydraulic phenomena during a DVI (Direct Vessel Injection) line break LOCA (Loss-of-Coolant Accident) in the APR1400 (Advanced Power Reactor 1400 MWe), we performed experimental studies with the SNUF (Seoul National University Facility), a reduced-height and reduce-pressure integral test loop with a scaled down APR1400. We performed experiments dealing with eight test cases under varied tests. As a result of the experiment, the primary system pressure, the coolant temperature, and the occurrence time of the downcomer seal clearing were affected significantly by the thermal power in the core and the SI flow rate. The break area played a dominant role in the vent of the steam. For our analytical investigation, we used the MARS code for simulation of the experiments to validate the calculation capability of the code. The results of the analysis showed good and sufficient agreement with the results of the experiment. However, the analysis revealed a weak capability in predicting the bypass flow of the SI water toward the broken DVI line, and it was insufficient to simulate the streamline contraction in the broken side. We, hence, need to improve the MARS code.

EXPERIMENTAL SIMULATION OF A DIRECT VESSEL INJECTION LINE BREAK OF THE APR1400 WITH THE ATLAS

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Kang, Kyoung-Ho;Choi, Nan-Hyun;Kim, Dae-Hun;Park, Choon-Kyung;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.655-676
    • /
    • 2009
  • The first-ever integral effect test for simulating a guillotine break of a DVI (Direct Vessel Injection) line of the APR1400 was carried out with the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) from the same prototypic pressure and temperature conditions as those of the APR1400. The major thermal hydraulic behaviors during a DVI line break accident were identified and investigated experimentally. A method for estimating the break flow based on a balance between the change in RCS inventory and the injection flow is proposed to overcome a direct break low measurement deficiency. A post-test calculation was performed with a best-estimate safety analysis code MARS 3.1 to examine its prediction capability and to identify any code deficiencies for the thermal hydraulic phenomena occurring during the DVI line break accidents. On the whole, the prediction of the MARS code shows a good agreement with the measured data. However, the code predicted a higher core level than did the data just before a loop seal clearing occurs, leading to no increase in the peak cladding temperature. The code also produced a more rapid decrease in the downcomer water level than was predicted by the data. These observable disagreements are thought to be caused by uncertainties in predicting countercurrent flow or condensation phenomena in a downcomer region. The present integral effect test data will be used to support the present conservative safety analysis methodology and to develop a new best-estimate safety analysis methodology for DVI line break accidents of the APR1400.

A study on Code System of Latin Character to Improve Transmission Efficiency in Data Communications (데이터통신 전송효율과 라틴어 부호 체계 고찰)

  • Hong, Wan-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.761-776
    • /
    • 2012
  • This paper proposes the revised Roman character code system using Unicode 3.0. The background of the paper is whether the Latin character code system th using in the world in Unicode V.3 is proper or not in the side of the transmission efficiency in data communications. In data communications, when the consecutive 4 bits or 8 bits of "0" bit from the information devices input into the line coder, its consecutive "0" bits are scrambled to the predetermined bit patterns to avoid the syncronization loss. The paper was based on the statistical data for the using frequency of the alphabet letter and the proposed rule for characters coding in [1]. The paper was focused to improve of Unicode itself and UTF-8 code system. As a result of the paper, when the proposed coding systems for Latin character in Unicode 3.0 itself and UTF-8 code system, the scrambler efficiency using HDB-3 in the line coder of the data transmission system could be improved about 3645 ~ 31400% and 480 ~ 1700% respectively.

Iterative Coding for High Speed Power Line Communication Systems (고속 전력선 통신 시스템을 위한 반복 부호화 기법)

  • Kim, Yo-Cheol;Cho, Bong-Youl;Lee, Jae-Jo;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.185-192
    • /
    • 2011
  • In this paper, we simulate and analyze performance of iterative coding scheme, double binary turbo code, for high speed power line communication (PLC) systems. PLC system has hostile environment for high speed data transmission, so error correction method is necessary to compensate effects of PLC channel. We employ the PLC model proposed by M. Zimmerman and Middleton Class A interference model, and system performance is evaluated in terms of bit error rate (BER). From the simulation results, we confirm double binary turbo code provides considerable coding gains to PLC system and BER performance is significantly improved as the number of iteration increase. It is also confirmed that BER performance increases as code rate is lager, while it decreases as the code rate is smaller.