• 제목/요약/키워드: Line Stability Index

검색결과 48건 처리시간 0.022초

A Novel Line Stability Index for Voltage Stability Analysis and Contingency Ranking in Power System Using Fuzzy Based Load Flow

  • Kanimozhi, R.;Selvi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.694-703
    • /
    • 2013
  • In electric power system, the line stability indices adopted in most of the instances laid stress on variation of reactive power than real power variation of the transmission line. In this paper, a proposal is made with the formulation of a New Voltage Stability Index (NVSI) which originates from the equation of a two bus network, neglecting the resistance of transmission line, resulting in appreciable variations in both real and reactive loading. The efficacy of the index and fuzzy based load flow are validated with IEEE 30 bus and Tamil Nadu Electricity Board (TNEB) 69 bus system, a practical system in India. The results could prove that the identification of weak bus and critical line in both systems is effectively done. The weak area of the practical system and the contingency ranking with overloading either line or generator outages are found by conducting contingency analysis using NVSI.

Stability Index Based Voltage Collapse Prediction and Contingency Analysis

  • Subramani, C.;Dash, Subhransu Sekhar;Jagdeeshkumar, M.;Bhaskar, M. Arun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.438-442
    • /
    • 2009
  • Voltage instability is a phenomenon that could occur in power systems due to stressed conditions. The result would be an occurrence of voltage collapse leading to total blackout of the system. Therefore, voltage collapse prediction is an important part of power system planning and operation, and can help ensure that voltage collapse due to voltage instability is avoided. Line outages in power systems may also cause voltage collapse, thereby implying the contingency in the system. Contingency problems caused by line outages have been identified as one of the main causes of voltage instability in power systems. This paper presents a new technique for contingency ranking based on voltage stability conditions in power systems. A new line stability index was formulated and used to identify the critical line outages and sensitive lines in the system. Line outage contingency ranking was performed on several loading conditions in order to identify the effect of an increase in loading to critical line outages. Correlation studies on the results obtained from contingency ranking and voltage stability analysis were also conducted, and it was found that line outages in weak lines would cause voltage instability conditions in a system. Subsequently, using the results from the contingency ranking, weak areas in the system can be identified. The proposed contingency ranking technique was tested on the IEEE reliability test system.

듀얼 공간을 이용한 이차원 두 손가락 로봇의 파지 안정성 분석 및 최적 파지 계획 (Grasp Stability Analysis in Dual-Space and Optimal Grasp Planning for Two-Fingered Robots in 2-D)

  • 국명호;장명언;이지홍
    • 제어로봇시스템학회논문지
    • /
    • 제12권11호
    • /
    • pp.1102-1110
    • /
    • 2006
  • This paper addresses the problem of computing grasp stability of the object for two-fingered robots in two dimensions. The concepts of force-closure and dual space are introduced and discussed in novel point of view, and we transform friction cones in a robot work space to line segments in a dual space. We newly define a grasp stability index by calculating intersection condition between line segments in dual space. Moreover, we propose a method to find the optimal grasp points of the given object by comparing the defined grasp stability index. Its validity and effectiveness are investigated and verified by simulations for quadrangle object and elliptic objects.

Line Security Evaluation of WANS Considering Protectability of Relays and Vulnerability of Lines

  • Hussain, Akhtar;Seok, Chang-Ju;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Seong-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1864-1872
    • /
    • 2014
  • Maloperation of protective relays is one of the major causes for cascading tripping in WANS. Another line trip followed by a previous line trip may occur due to overloading of the line, because of the load redistribution or unwanted trip of a backup relay due to change in the flow of fault current. Evaluation of each line is required by considering both of these effects. A new index named Line Security Index (LSI) is proposed in this paper which combines both Vulnerability Index (VI) and Protectability Index (PI) to completely evaluate the security of individual lines and their importance in the power grid. Computer simulations have been performed on the Korean power grid data to establish the feasibility of the proposed idea.

송전선 절체제어에 의한 전력계통 안정화 연구 (A Study on Transient Stability Augmentation by Transfering Line and Bus)

  • 서의석;오태규;한후석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1029-1032
    • /
    • 1998
  • This paper presents the scheme of bus and line transfer for improving transient stability and the reactive transient stability index usable in time simulation. And also multi-transferring scheme for improving damping is proposed. These results can be applied in determining the effective position for transfer control.

  • PDF

송전선 절체제어에 의한 전력계통 안정화 연구 (A Study on Transient Stability Augmentation by Transfering Line and Bus)

  • 서의석;오태규;한후석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.681-684
    • /
    • 1998
  • This paper presents the scheme of bus and line transfer for improving transient stability and the relative transient stability index usable in time simulation. And also multi-transferring scheme for improving damping is proposed. These results can be applied in determining the effective position for transfer control.

  • PDF

송전선 절체제어에 의한 전력계통 안정화 연구 (A Study on Transient Stability Augmentation by Transfering Line and Bus)

  • 서의석;오태규;한후석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.361-364
    • /
    • 1998
  • This paper presents the scheme of bus and line transfer for improving transient stability and the relative transient stability index usable in time simulation. And also multi-transferring scheme for improving damping is proposed. These results can be app1ied in determining the effective position for transfer control.

  • PDF

변전소내 지역정보를 이용하여 안정도 향상을 위한 실시간 OLTC 및 커패시터 협조제어 알고리즘 (On-line coordination control of OLTC and Switched Shunt for enhancement of stability using local data in substation)

  • 강상균
    • 한국산업정보학회논문지
    • /
    • 제17권7호
    • /
    • pp.119-125
    • /
    • 2012
  • 본 논문은 변전소 내에서 취득된 데이터만을 이용하여 전계통 전압안정도를 확보하기 위한 실시간 변전소내 OLTC(On-Load Tap Changer)와 S.S(Switched Shunt)와의 협조제어 알고리즘을 제안하고자 한다. 전압레벨을 일정한 값으로 유지시키기 위해서 동작하는 OLTC의 제어를 잘못하게 된다면 오히려 계통의 안정도(전압안정도) 를 해치는 결과를 나타낼 수 있다. 이 논문에서는 단일 변전소에서 취득된 데이터만으로 전체 시스템의 상태를 판단할 수 있는 Z-index를 이용하였다. Z-index를 이용하여 시스템을 normal 상태와 abnormal 상태로 구분하였고, 각 상태에 따른 협조제어 알고리즘을 제안하였다. 알고리즘 검증을 위해서 Hypersim과 matlab simulink를 이용하였다.

A Fast Contingency Screening Algorithm for On-line Transient Security Assessment Based on Stability Index

  • Nam, Hae-Kon;Kim, Yong-Hak;Song, Sung-Geun;Kim, Yong-Gu
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권4호
    • /
    • pp.131-135
    • /
    • 2002
  • This paper describes a new ultra-fast contingency screening algorithm for on-line TSA without time simulation. All machines are represented in a classical model and the stability index is defined as the ratio between acceleration power during a fault and deceleration power after clearing the fault. Critical clustering of machines is done based on the stability index, and the power-angle curve of the critical machines is drawn assuming that the angles of the critical machines increase uniformly, while those of the non-critical ones remain constant. Finally, the critical clearing time (CCT) is computed using the power-angle curve. The proposed algorithm is tested on the KEPCO system comprised of 900-bus and 230-machines. The CCT values computed with the screening algorithm are in good agreement with those computed using the detailed model and the SIME method. The computation time for screening about 270 contingencies is 17 seconds with 1.2 GHz PC.

안정도 지수와 에너지 마진을 이용한 불안정 발전기의 clustering 법 (A Novel Method for Clustering Critical Generator by using Stability Indices and Energy Margin)

  • 장동환;정연재;전영환;남해곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.441-448
    • /
    • 2005
  • On-line dynamic security assessment is becoming more and more important for the stable operation of power systems as load level increases. The necessity is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices. Case study shows very promising results.