• Title/Summary/Keyword: Line Rupture

Search Result 81, Processing Time 0.025 seconds

A Reliability Analysis of HHSIS of KNU 5,6,7 and 8 Following the Removal of s-signal from Charging/safety Injection Pump Mini-flow Line Valves (충전/안전주입 펌프 순환배관의 안전주입신호 제거에 따른 원자력 5,6,7,8 호기의 고압안전주입계통의 신뢰도 분석)

  • Chung, Dae-Wook;Chung, Chang-Hyun;Kang, Chang-Soon
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.47-53
    • /
    • 1988
  • The objective of this study is to evaluate the reliability of the High Head Safety Injection System (HHIS) of KNU 5, 6, 7 and 8 following the removal of safety injection signal (s-signal) from the mini-flow bypass line valves of charging/safety injection pumps. The unavailability of HHSIS and the rupture probability of a charging/safety injection pump have been computed for two different cases; with s-signal on and removed. The results show that when the s-signal is removed from the mini-flow bypass line valves, the unavailability of HHSIS slightly increases while the rupture probability of a charging/safety injection pump is significantly reduced. Hence, based upon the results of this study we conclude that it is more reasonable to remove the s-signal from the mini-flow bypass line valves of KNU 5, 6, 7 and 8 in the normal plant operation. And to improve the availability of HHSIS, the modification of operational procedures and the emphasis on operator training are recommended.

  • PDF

The Use of Nylon Tube as Aortic Prostheses: 2 Cases (Nylon tube를 이용한 대동맥 Prostheses (2례))

  • 윤윤호;정영환;김근호
    • Journal of Chest Surgery
    • /
    • v.3 no.1
    • /
    • pp.47-54
    • /
    • 1970
  • This is a report on two cases of aortic prostheses using Nylon tube. (Edwards-Tapp A-G Tube, Chemically treated braided Nylon arterial grafts). Especially, the complications after infection of synthetic graft are discussed with reviewing literature. First case was the patient who came to our hospital with rupture of the right femoral artery at the femoral fossa due to pyogenic necrotic process. After femoral arterial prostheses, good pulsation of dorsal artery of foot was obtained. However, the tube was obstructed after 8 weeks postoperatively due tll the complication of infection. In spite of the tube was removed because of obstruction and foreign body reaction of synthetic graft, an amputation of the leg was not necessary for formation of good collateral circulation. Second case was a case of aortic aneurysmal rupture in thoraco-abdominal junction which developed by the trauma of rib resection for osteomyelitis of the left 12th. rib An implantation of aortic graft was performed at the lowest tho13cic aorta by the way of thoraco-abdominal bypass without arterial pump. However, infection produced pyothorax in the left pleural cavity, exposing the tube within the pyothorax. The rupture of the anastomosed upper line occurred in 8 weeks postoperatively and the patient expired.

  • PDF

A study on the KLA behaviors in HAZ and the mechanical properties of austenitic stainless steel weld (스테인레스강용접 열영향부의 KLA거동 및 기계적 특성에 관한 연구)

  • 조종춘;김영석;김학민
    • Journal of Welding and Joining
    • /
    • v.8 no.4
    • /
    • pp.27-34
    • /
    • 1990
  • Integranular corrosion behaviors of KAL (Knife Line Attack) and mechanical properties such as tensile and creep rupture were investigated for the tube material used for nearly 20 years under the condition of 463.deg. C and 28 $kg/cm^2$. Based and weld metal were austenitic stainless steel AISI 321 containing Ti, AISI 347 containing Nb, respectively. KLA is a kind of the intergranular corrosion which often occurs just near the HAZ (heat affected zone) of AISI 321 and AISI 347 stainless steel due to the grain boundary sensitization. In KLA zone, intergranular corrosion crack has propagated outwards from the inner surface and carbides of white and narrow band type assuming as (Cr, Fe) carbide were confirmed. All the delta-ferrite formed in the weld metal during weld solidification has been transformed into sigma-phase since delta-ferrte was exposed for 20 years at 463.deg. C. Elongation was very low at the range from room temperature to 600.deg. C and it was confirmed that creep-rupture properties were not consideralbly affected.

  • PDF

Ascending Aortic Dissection due to Trauma - A Case report - (외상에 의한 상행 대동맥 박리증의 치험 1례)

  • Seo, Pil-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.174-177
    • /
    • 1990
  • Aortic dissection is a challenging disease and the causes of that are well-known. Blunt chest trauma is one of the causes of aortic dissection. In such cases, nearly all cases involves the isthmic portion of descending aorta, but ascending aorta is involved in about 10. We experienced a patient who had ascending aortic dissection due to automobile accident and who showed spontaneous rupture of the aorta during operation. In this case, after installation of aortic line via left femoral artery, ascending aorta ruptured and a large amount of blood gushed out, which was suckered by cardiotomy sucker. A little delay of cardiopulmonary bypass may cause the fatal outcome in such a case because the bleeding from aorta is too much to be controlled. Fortunately, we controlled the bleeding with cardiopulmonary bypass and got the good outcome of this patient by interpositioning the vascular graft. One should suspect the possibility of aortic dissection in blunt chest trauma, and prepare all the facilities against bleeding due to rupture.

  • PDF

A Study on Damage Evaluation Austenitic Stainless Steel Tube Material (오스테나이트계 내식강 튜브 소재의 손상진단에 관한 연구)

  • Jo, Jong-Chun;Kim, Yeong-Seok;Kim, Hak-Min;Jeong, Hyeong-Jo
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.43-52
    • /
    • 1989
  • Material damage of Unifiner Change Heater: Tube used for nearly 20 years was evaluated and Mechanical tests such as tensile tests and creep-rupture tests were conducted to predict the residual life. After the investigation, any major damage or degradation was not found except the welded zone. Microstructural observation showed that most of delta-ferrite was transformed. to sigma-phase and consequently, the ductility was very much reduced. A KLA(Knife-Line Attack) crack with 60mm in length and 2.8mm in depth was found just near the welded zone, which is believed to be caused by intergranular corrosion. Creep-rupture tests, which are very essential to predict the residual life, showed that both used base and weld metals have similar results with the reference data.

  • PDF

Synthesis of Earthquake Ground Motion by Combining Stochastic Line Source Model with Elastic Wave Propagation Analysis Method in a Layered Half Space (추계학적 선진원 모델과 층상반무한체에서의 탄성파 전파 해석법에 의한 지진 지반운동 합성)

  • KIM, Jae Kwan;KWON, Ki Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.97-105
    • /
    • 1996
  • A Stochastic line source model is developed to simulate the seismic wave field generated during the rupture propagation process along a fault plane of which length is much larger than its width. The fault plane is assumed to consist of randomly distributed slip zones and barriers and each slip zone is modeled as a point source. By combining the newly developed source model with wave propagation analysis method in a layered 3-D visco-elastic half space, synthetic seismograms are obtained. The calculated accelerograms due to vertical dip slip and strike slip line sources are presented.

  • PDF

Evaluation of Blast Wave and Pipe Whip Effects According to High Energy Line Break Locations (고에너지배관 파단위치에 따른 배관휩과 충격파의 영향 평가)

  • Kim, Seung Hyun;Chang, Yoon-Suk;Choi, Choengryul;Kim, Won Tae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.54-60
    • /
    • 2017
  • When a sudden rupture occurs in high energy lines, ejection of inner fluid with high temperature and pressure causes blast wave as well as thrust forces on the ruptured pipe itself. The present study is to examine pipe whip behaviors and blast wave phenomena under postulated pipe break conditions. In this context, typical numerical models were generated by taking a MSL (Main Steam Line) piping, a steam generator and containment building. Subsequently, numerical analyses were carried out by changing break locations; one is pipe whip analyses to assess displacements and stresses of the broken pipe due to the thrust force. The other is blast wave analyses to evaluate the broken pipe due to the blast wave by considering the pipe whip. As a result, the stress value of the steam generator increased by about 7~21% and von Mises stress of steam generator outlet nozzle exceeded the yield strength of the material. In the displacement results, rapid movement of pipe occurred at 0.1 sec due to the blast wave, and the maximum displacement increased by about 2~9%.

A Study on the Characteristic for Abnormal Tension of Overhead Optical Communication Line (가공 광통신선의 이상 장력에 대한 특성 연구)

  • Cho, Hyun-Seob;Han, Kun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.658-663
    • /
    • 2008
  • In this study, we estimated the influence of electrical pole by FEM(Finite Element Method) and developed protective system by designing and interpreting protective system for electrical pole and overhead optical communication line when abnormal strength worked on messenger wire. Protective system did not shed messenger wire under wind pressure and discontent load but did assign a part to preventing rupture of electrical pole and disconnection of optical communication line through automatically shed messenger wire over fixed strength. Structure of protective system analysis by FEM and prove property by measuring tensile strength for practical product.

Triple Tibial Osteotomy (TTO) for Treatment of Cranial Cruciate Ligament Rupture in Small Breed Dogs

  • Kim, Tae-Hwan;Hong, Subin;Moon, Heesup;Shin, Jeong-In;Jang, Yun-Sul;Choi, Hyeonjong;Kim, In-Geun;Lee, Jae-hoon
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • Twelve dogs weighing less than 10 kg underwent unilateral TTO to stabilize the stifle joint with cranial cruciate ligament rupture. Surgical findings, intra-operative and post-operative complications were recorded. Radiographic examinations were performed for 8 weeks following surgery. Postoperative outcome was evaluated using a visual analogue lameness scoring system. Mean preoperative PTA (the angle created by the intersection of the tibial plateau extrapolation line and the patellar tendon) was 103.8 degrees. Mean tibial wedge angle was 16.6 degrees. Mean postoperative PTA was 92.1 degrees. Intraoperatively, fracture through the caudal tibial cortex occurred in all dogs, through the distal tibial crest cortex in 2 dogs, through the lateral tibial cortex in 2 dogs and through the fibula in 1 dog. Four-week postoperative radiographs demonstrated evidence of progressive bone union at osteotomy site and complete unions were identified at 8 week in 10 dogs. All dogs were healed in 11 weeks. Most of dogs revealed weak lameness in 4 weeks and normal ambulation in 8 weeks postoperatively except for only one dog returned in 11 weeks. Despite frequent minor complication, it appears that the TTO is an alternative procedure for management of cranial cruciate ligament rupture in small breed dogs.

Investigation of the Experiment for Separation Distance between Powerline Earth and Pipelines (전력선 접지와 매설배관의 이격거리 실증실험 사례 조사)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.87-88
    • /
    • 2006
  • There are a number of reported instances of actual pipeline rupture during power line faults caused by melting of the pipe wall. This type of hazard was considered to be among the most serious of AC effects on pipelines in an international survey, comparable to the personnel safety hazard. Moreover, resistance coupling is not only a risk when the pipeline parallels a power line but also when they cross. One method of minimizing the effects of resistive coupling is by maintaining an appropriate separation distance between the pipeline and tower. This paper investigate the experiment for separation distance between the powerline earth and pipelines.

  • PDF