• Title/Summary/Keyword: Line Beam

Search Result 811, Processing Time 0.029 seconds

Depth Measurement Method Robust against Scattering of Line Lasers (라인 레이저의 산란에 강인한 심도 측정 방법)

  • Ko, Kwangjin;Yeon, Sungho;Kim, Jaemin
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.181-187
    • /
    • 2018
  • Line-laser beams are used for depth measurement of welding beads along the circumference of a pipe. For this, first we project a line-laser beam on an rotating pipe and take a sequence of images of the beam projected on the pipe using a CCD camera. Second, the projected line laser beam in each image is detected, converted into a thin curve. Finally measure the distance between the thinned curve and an imaginary line. When a line-laser beam is projected to a rough metal surface such as arc welding beads, the beam is severely scattered. This severe scattering makes the thinned curve perturbed. In this paper, we propose a thinning method robust against scattering of line lasers. First, we extract a projected line laser beam region using an adaptive threshold. Second, we model a thinned curve with a spline curve with control points. Next, we adjust the control points to fit the curve to the projected line-laser beam. Finally, we take a weighted mean of thin curves on a sequence of image frames. Experiments shows that the proposed thinning method results in a thinning curve, which is smooth and fit to the projected line-laser beam with small error.

Oprimization Study for the CRC PIXE System Beam Transport Line

  • Jeong, Cheol-Ki;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.59-63
    • /
    • 2014
  • Proton Induced X-ray Emission (PIXE) is a MeV ion beam analysis method for use with particle accelerators. PIXE uses low-energy charged particles as an excitation mechanism to generate characteristic x-ray emission from each element in a target. In PIXE analysis, the beam current used is from a few nA to several tens of nA. Chosun University (Cyclotron Research Center) designed a $50{\mu}A$ beam line from the 13 MeV cyclotron for use with a PIXE analysis system, as well as performing beam transport line optimization research. In this study, the beam line operation conditions for the optimization process of beam transport and beam characteristics are shown.

Iterative Polynomial Fitting Technique Using Polynomial Coefficients for the Nonlinear Line Array Shape Estimation (비선형 선배열 형상 추정을 위한 계수 반복 다항 근사화 기법)

  • Cho, Chom Gun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.20-25
    • /
    • 2006
  • Low frequency towed line array with high array gain and beam resolution is a long range surveillance sensor for anti-submarine warfare. The beam characteristics is however deteriorated due to the distorted line array sensor caused by low towing speed, wind, current, and towing ship maneuvering. An adaptive beamforming method is utilized in this paper to enhance the distorted line array beam performance by estimating and compensating the nonlinear array shape. A polynomial curve fitting in the least square sense is used to estimate the array shape iteratively with the distributed heading sensors data along the array. Real time array shape estimation and nonlinear array beam calculation is applied to a very long towed line array sensor system and the beam performance is evaluated and compared to the linear beamformer for the simulation and sea trial data.

Left/Right Bearing Discrimination with Adaptive Cardioid Beamforming (적응 카디오이드 빔 형성을 이용한 좌/우 방위 분리 기법)

  • 손윤준;천승용;김기만
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.489-495
    • /
    • 2003
  • Single towed line array receiver contains an ambiguity on conjugate bearings because of lacking aperture in transverse direction. To solve the left/right bearing ambiguity of line array receiver this paper proposed using single line array with fixed cardioid beam. Fixed cardioid beam has problem about back beam gain exists for steering beam inherent. Back beam is makes form on direction that is different from actually source so that reduced the performance of left/right bearing discrimination. In this paper, line way with adaptive cardioid beam for resolve problem of back beam gain is proposed. So the proposed method has more improved left/right bearing discrimination than fixed cardioid beam, Simulation results show the performance of the proposed method.

Frequency Characteristics of Surface Wave Generated by Single-Line Pulsed Laser Beam with Two Kinds of Spatial Energy Profile Models: Gaussian and Square-Like

  • Seo, Ho-Geon;Kim, Myung-Hwan;Choi, Sung-Ho;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.347-354
    • /
    • 2012
  • Using a single-line pulsed laser beam is well known as a useful noncontact method to generate a directional surface acoustic wave. In this method, different laser beam energy profiles produce different waveforms and frequency characteristics. In this paper, we considered two typical kinds of laser beam energy profiles, Gaussian and square-like, to find out a difference in the frequency characteristics. To achieve this, mathematical models were proposed first for Gaussian laser beam profile and square-like respectively, both of which depended on the laser beam width. To verify the theoretical models, experimental setups with a cylindrical lens and a line-slit mask were respectively designed to produce a line laser beam with Gaussian spatial energy profile and square-like. The frequency responses of the theoretical models showed good agreement with experimental results in terms of the existence of harmonic frequency components and the shift of the first peak frequencies to low.

Straight-line Path Error Reduction for the End of a Flexible Beam Deploying from a Rotating Rigid Hub (회전하는 강체허브에서 전개하는 보 끝단의 직선궤적오차 저감)

  • Kim, Byeongjin;Kim, Hyungrae;Chung, Jintai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.11
    • /
    • pp.898-906
    • /
    • 2014
  • This paper presents a reduction method for a straight-line path error of a flexible beam deploying from a rotating rigid hub. Previous studies discussed about only vibration phenomena of flexible beams deploying from rotating hubs; however, this study investigates a vibration reduction of a rotating beam with variable length. The equation of motion and associated boundary conditions are derived for a flexible beam deploying from a rotating rigid hub, and then they are transformed to a variational equation. By applying the Galerkin method, the discretized equations are obtained from the variational equation. Based on the discretized equations, the dynamic responses of a rotating/deploying beam are analyzed when the beam end has a straight line motion. A reduction method for the trajectory error is proposed, using the average length of a rotating/deploying beam. It is shown that the proposed method is able to reduce the residual vibration of a rotating/deploying beam.

A Stuty on Development of Spitted beam Type On-line Silica Analyzing sysyem (Splitted Beam Type On-line 실리카 분석기 개발에 관한 연구)

  • Jeong, Gyeong-Yeol;Lee, Hu-Rak
    • 연구논문집
    • /
    • s.30
    • /
    • pp.43-56
    • /
    • 2000
  • N-IR spectroscopy technology is very useful. And, the technology has wide application range. In the range, we know that single beam type silica analyzer has some handicap. So we were studied Splitted beam type silica analyzer. This dissertation have been discuss about system structure, system fundamentals and performance test. At the test, we were study in the spectral interference of NH3. We know that existing system had some problem. It is structural frailties of single beam type. Therefore we were study for Splitted beam type structure. And we obtain a good result. We have $\pm$5% accuracy and 0.5 ppb level measuring range. But, we have a question. It is ppt level measuring technology by the laser beam spectroscopy.

  • PDF

Research on BTU and Short-axis Geometry of Line-beam Optics for LLO Applications (레이저 박리용 선형 빔 광학계의 빔 변환 모듈과 단축 형상에 대한 연구)

  • Lee, Seungmin;Lee, Gwangjin;Kim, Daeyong;Lee, Sanghyun;Jung, Jinho
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.276-285
    • /
    • 2021
  • This paper reports the study of the line-beam optical system of the laser lift-off (LLO) equipment used in the OLED manufacturing process. To obtain both a long process depth and a narrow width of the line beam, even with the poor M2 value of the laser source, the research is focused on the optical system, including the beam transformation unit (BTU). We also propose optical configurations for the super-Gaussian distribution and the fiber-based BTU for the flat-top distribution.

A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy

  • Chung, Kwangzoo
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.129-133
    • /
    • 2017
  • The machine log files recorded by a scanning control unit in proton beam therapy system have been studied to be used as a quality assurance method of scanning beam deliveries. The accuracy of the data in the log files have been evaluated with a standard calibration beam scan pattern. The proton beam scan pattern has been delivered on a gafchromic film located at the isocenter plane of the proton beam treatment nozzle and found to agree within ${\pm}1.0mm$. The machine data accumulated for the scanning beam proton therapy of five different cases have been analyzed using a statistical method to estimate any systematic error in the data. The high-precision scanning beam log files in line scanning proton therapy system have been validated to be used for off-line scanning beam monitoring and thus as a patient-specific quality assurance method. The use of the machine log files for patient-specific quality assurance would simplify the quality assurance procedure with accurate scanning beam data.

$CO_2$ Laser Irradiation Strengthening by Defocused Beam (비집속빔을 이용한 $CO_2$ 레이저 빔 조사강화)

  • Seo, Jung;Lee, Je-Hoon;Kang, Hee-Sin;Kim, Jung-Oh;Lee, Moon-Yong;Oh, Sang-Jin;Lee, Kyu-Hyun
    • Laser Solutions
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2003
  • Defocused CO$_2$ laser beam irradiation strengthening of 60kgf/$\textrm{mm}^2$ grade steel sheet was investigated to obtain the tensile strength similar to that of fully penetrated one by the focused beam. The melted line width by the defocused beam was 3∼4 times larger compared to that of the focused beam. However, the increase of tensile strength with 1 line irradiation by the defocused beam was similar to that of 2~3 lines by the focused beam. The increase(37.6%) of bending strength with 1 line by the defocused beam was higher than the increase(12.9%) of tensile strength. Also, the effect of cooling gas to strengthening was observed.

  • PDF