Comparison of LAL Test with Pyrogen Test (발열성 물질시험과 세균 내독소 시험의 비교 연구)

  • 이유경;강윤숙;백선영;김용관;신광훈;민홍기
    • YAKHAK HOEJI
    • /
    • v.43 no.5
    • /
    • pp.606-613
    • /
    • 1999
  • To survey the possibility of replacing the pyrogen test with Limulus Amebocyte Lysate(LAL) test and to find out a standard methods suitable to our blood products made in Korea, 100 samples of 20% human serum albumin were tested by commercial LAL test kits and results of those were compared with rabbit pyrogen test. The LAL test is used both dinetic-chromogenically and kinetic-turbidimetrically. Both methods equally showed broad detection range (5.0~0.005 EU/ml), excellent sensitivity ($\geq$ 0.005 EU/ml) and predominant recovery rate within valid dilution range, but kinetic-turbidimetric method seemed to be more reproducible than kinetic-chromogenic method(kinetic-chromogenic method : S.D. = 15.88, kinetic-turbidimetric method : S.D. = 8.12). After heating the sample at 75$^{\circ}C$ for 15 min, the results showed a little elevated recovery rate with both methods. After performing the test on 100 albumin samples with both kits, the results were analysed using the USP standard (1.33 EU/ml). 7% of samples in kinetic-chromogenic methods and 1% of samples in kinetic-turbidimetric method exceeded the limit of endotoxin levels regulated for blood products in USA. Because this phenomenon was not observed in both methods at the same time and both methods have high sensitivity ($\geq$0.005 EU/ml), these results seemed to depend on nonspecific reaction. Considering its sensitivity and reproducibility, we could assure that LAL test is proper to detecting pyrogenic with good sensitivity.

  • PDF

Studies on Effects of Antibiotics on Pyrogen Tests

  • Shin, Kwang-Bum;Song, Young-Joon;Kim, Jung-Woo
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.2
    • /
    • pp.85-88
    • /
    • 1986
  • To estimate the effect of some injectable antibiotics (ampicillin sodium, cefazolin sodium, cephaloridine, cefuroxime sodium and chloramphenicol sodium succinate) on pyrogen tests, the Limulus amebocyte lysate (LAL) test and an ultrafiltration technique were used. The rabbit pyrogen test was also used in the case of cafazolin sodium. At high antibiotic concentrations, these samples which were artificially contaminated with endotoxin inhibited the gelation reaction of LAL. But the gelation reaction occurred when most of the antibiotic was removed by ultrafiltration. Likewise, cefazolin sodium interfered not only with the LAL test but also with the rabbit pyrogen test. From these results it can be said that special modification to eliminate interference should be taken into consideration for valid method of pyrogen tests in the parenteral products containing these antibiotics.

  • PDF

Feasibility Study for a Lab-chip Development for LAL Test (LAL 시험용 Lab-chip 개발을 위한 타당성 연구)

  • 황상연;최효진;서창우;안유민;김양선;이은규
    • KSBB Journal
    • /
    • v.18 no.5
    • /
    • pp.429-433
    • /
    • 2003
  • LAL (Limulus amebocyte lysate) test to detect and quantity endotoxin is based on gellation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive requiring dedicated personnel, takes relatively long reaction time (approximately 1 hr), requires relatively large volume of samples and reagents, and its end-point detection method is rather subjective. To solve these problems, we attempted to develop a miniaturized LOC (lab-on-a-chip) prototype using PDMS and glass. Using the 62 mm (length) ${\times}$ 18 mm (width) prototype in which 2 mm (width) ${\times}$ 44.34 mm (length) ${\times}$ 100 $\mu\textrm{m}$ (depth) microfluidic channel was provided, we compared the various detection methods of gellation, turbidometric, and chromogenic assays to find the chromogenic method to be the most suitable for small volume assay. In this assay, kinetic point method was more accurate than end point method. We also found the PDMS chip thickness should be minimized to around 2 mm to allow sufficient light transmittance, which necessitated a glass slide bonding for chip rigidity. Through the miniaturization, the test time was reduced from 1 hr to less than 10 minutes, and the sample volume could be reduced from 100 ${\mu}\ell$ to 4.4 ${\mu}\ell$. In sum, this study revealed that the mini LOC could be an alternative for a semi-automated and reliable method for LAL test.

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

Safety evaluation of bacteriophages for application as sanitizers (박테리오파지의 살균소독제 응용을 위한 안전성 평가)

  • Park, Do-Won;Lee, Young-Duck;Park, Jong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.109-112
    • /
    • 2020
  • To evaluate the safety of bacteriophages for application of sanitizer, endotoxin content and cell cytotoxicity of two Escherichia coli and four Staphylococcus aureus phages were determined. Endotoxin ratio was determined by the Limulus amebocyte lysate (LAL) assay as a test for representative biological endotoxin content. The average endotoxin average content of the 9 log PFU/mL lysate was 18.6 EU/mL and that of the 10 log PFU/mL lysate was 5.9 EU/mL, suggesting that the phage lysate was not suitable for clinical applications, but suitable for food pathogen control applications. To confirm the cell cytotoxicity of the phage lysates, MTT assay was performed using Raw 264.7 cells treated with 9 log PFU/mL phages. Results of the assay indicated that the phage lysates did not significantly decrease the cell viability (p>0.05). These results indicated that bacteriophages would be suitable as a food safety sanitizer.

Development of an Improved Endotoxin Detection Method Using Centrifugation (원심분리법을 이용한 혈청 내 내독소의 개선된 측정방법 연구)

  • Choi, Hyeong Jwa;Lim, Yoo Jung;Lee, Eun Hee;Park, Jin Yeon;Prabagar, Miglena G.;Park, Hyung Soon;Kang, Young Sun
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.2
    • /
    • pp.242-248
    • /
    • 2013
  • Endotoxins are part of the outer membrane of the cell wall of gram-negative bacteria and are continuously released during bacterial growth. Endotoxins typically induce severe sepsis and septic shock, which cause more than 50% of mortalities. Endotoxins are easily measured in the serum by the limulus amebocyte lysate (LAL) test. However, a nonspecific result is obtained, because the high concentration of serum proteins disturbs the enzyme reaction of the LAL test. In order to solve this problem, the LAL test was performed in this study after the centrifugation of the boiled serum samples to remove the impurities. As a result, among the various conditions examined, endotoxin measurement with the LAL test was the most accurate and repeatable after centrifugation of the boiled serum at $100^{\circ}C$. Moreover, the endotoxin was accurately and repeatedly measured from the prepared sera of mice that had been administered an intraperitoneal injection of purified lipopolysaccharides (LPS) or E. coli. Therefore, the application of centrifugation to remove impurities from boiled serum gives an accurate measurement of endotoxins in the sera of normal subjects or patients, and this will lead to the improved diagnosis and prevention of diseases caused by endotoxins. In addition, the centrifugation of boiled serum samples should be considered and included in the development of endotoxin test kits.

Comparison of Quantitative Endotoxin against 5 Species of Enterobacteriaceae (장내세균 5종의 Endotoxin 정량 비교)

  • Kwon, Pil Seung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • Endotoxin, also known as lipopolysaccharide (LPS) produced by the cell wall of gram negative bacteria can be present in any liquid or on any biomaterial. Endotoxin in blood can cause fever and inflammation. In this study, we compared bacterial endotoxin using Escherichia coli O157:H7, Klebsiella oxytoca, Salmonella Typhi, Shigella sonnei and Morganella morganii. Bacteria were cultured for use in the experiment, and diluted to $1.5{\times}10^8CFU/mL$. A check marked sensitivity confirmatory test of the Limulus amebocyte lysate (LAL) reagent was performed to examine the validity. The end point reaction to each bacteria sample was confirmed with 10 fold dilution and then the final reaction end point was confirmed by 2 fold dilution between the dilution step and the upper dilution step. According to the results, in detection of endotoxins in more than 0.015 EU/mL, E. coli O157 was 75~37.5 CFU/mL, K. oxytoca 37.5~18.75 CFU/mL, M. morganii and S. Typhi 3.75~1.875 CFU/mL, and S. sonnei 7.5~3.75 CFU/mL. The resulting value was finally ensured by a confirmation test for the inhibitory factor. Based on this study, conduct of further research on bacterial endotoxin is encouraged.