• 제목/요약/키워드: Limiting solid flux

검색결과 7건 처리시간 0.018초

DAF 슬러지의 부상식 농축; 고형물 플럭스법 적용과 영향인자 (Thickening of Sludge from DAF process by Flotation; Application of Solid Flux Theory and Effective Factors)

  • 박상철;한무영;독고석;권순범
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.617-626
    • /
    • 2006
  • Compared with the sludge from gravity sedimentation, it is difficult for operations to settle the sludge occurred from dissolved-air-flotation (DAF). Even though there are some problems in treating DAF sludge with conventional gravity thickeners, those has been used until now. In this study, Solid Flux theory for gravity thickening was applied to the Solid Flux of DAF sludge through flotation in order to develop new methodology for treatment of DAF sludge. Also, characteristics of DAF sludge were investigated. From the experiment results, it was revealed that the higher the polymer dosage, at fixed the solid concentration, the greater the rising velocity becomes. When we applied solid flux theory, the relationship, which is similar to that of gravity thickening, has been achieved. Also, we could find the proper polymer dosage from the rising velocity is about 50 mg/L. Consequently, the limiting solid flux can be derived from the relationship between the total solid flux and the withdrawal velocity of DAF sludge. Furthermore, the factors, such as solid concentrations, bubble volume, pH, zeta potential, and temperature, have effects on the flotation and sedimentation for DAF sludge treatment.

정수장슬러지의 전처리에 의한 침전특성 (Settling Characteristics of Water Treatment Plant Sludges by Pretreatment Methods)

  • 문용택;이선주
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.627-632
    • /
    • 2008
  • It is necessary to investigate methods for improvement by diagnosing sludge settling characteristics on inflow of slurry to thickener. The results of the settling tests are correlated to determine zone settling velocities at the various sludge solids concentrations. Conditioning of WTP residuals is generally done by either chemical or physical treatment. The settling test was conducted with 1m columns dosing polymer to WTP residuals at various solids concentration. The estimated results for dosing to WTP residuals for a sludge of 2,100 ~ 16,012 mg/L solids concentration were the zone settling velocities of 48.38 ~ 6.8 m/day, supernatant solid concentration of 3.2 ~ 19 mg/L and solid flux of $101.6{\sim}317.61kg/m^3{\cdot}day$. The values for non-polymer treatment were the zone settling velocities of 28.37 ~ 0.12 m/day, supernatent solid concentration of 8.5 ~ 108 mg/L and solid flux of $59.58{\sim}1.92kg/m^2{\cdot}day$. The limiting solid flux value by Yoshioka methods was $4.0kg\;TS/m^3{\cdot}day$ for Non-polymer and $228.0kg\;TS/m^3{\cdot}day$ for dosing polymer. These results are to indicate a possibility of improvement on the thickening characteristics and the quality of supernatant as increasing the settling velocities by dosing polymer to WTP residuals.

세라믹 막 정수공정에서 발생하는 배출수의 농축특성 (Thickening Characteristics of Residual from a Ceramic Membrane Water Treatment Plant)

  • 배병욱;신성해
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.764-767
    • /
    • 2009
  • For a more effectively designed gravity thickener, thickening experiments were conducted for residuals produced by a ceramic membrane water treatment plant (WTP). Two kinds of residuals, one from backwashing (BW) and the other from chemically enhanced backwashing (CEB) procedure, were separately collected during a pilot plant experiment and their limiting solid flux ($SF_L$) measured. Batch thickening experiments showed that the BW and CEB residual had $SF_L$ of 10 and $25kg/m^2{\cdot}d$, respectively. Continuous operation of a pilot-scale gravity thickener proved that a mixed BW and CEB residual could be successfully thickened at the solid loading rate (SLR) of $12kg/m^2{\cdot}d$, allowing the concentration of the thickened residual to be about $15kg/m^2{\cdot}d$. From the experimental results and consideration of the seasonal thickening characteristics of the residual, SLR of $15kg/m^2{\cdot}d$ was proposed as a design parameter for full-scale gravity thickeners.

역세척수 회수시스템이 포함된 배출수처리공정의 설계 (Design of Residual Treatment Process with Filter Backwash Recycle System)

  • 배병욱;최경환
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.109-114
    • /
    • 2012
  • In this study, both sedimentation and thickening experiments were conducted for residuals produced from an advanced water treatment plant for more accurate and practical design of residual treatment train. In order to design a backwashed residual sedimentation basin (SRSB) in the filter backwash water recycle system, two kinds of backwash waters, one from sand filter (SFBW) and the other from GAC adsorption bed (GACBW), were separately collected and their surface loading rate measured. In addition, in order to design a gravity thickener, batch thickening tests were conducted for concentrated residuals taken from sedimentation basin and their limiting solid flux ($SF_{L}$) measured. From the experimental results and consideration of the seasonal characteristics of the residual, surface loading rate of $70m^{3}/m^{2}{\cdot}d$ was proposed as a design parameter for SRSB and solid loading rate of 20 kg $TS/m^{2}{\cdot}d$ was proposed as a design parameter for gravity thickeners. Finally, the material mass-balance was made for the design of each unit process in the residual treatment train.

다시마 열수 추출물의 한외 여과에 의한 분리 (Studies on the Separation of Hot Water Extract Seasoning Components from Sea Tangle by Using Ultrafiltration)

  • 강희호;이성갑
    • 기술사
    • /
    • 제32권2호
    • /
    • pp.99-109
    • /
    • 1999
  • The dried sea tangle added for soup prepatation to improved the taste in Korean and Japaness for long time. Attempts were made to develop the best procedures for extraction and removal of alginate by ultrafiltration and diafiltration. The summerized results of this study are as follows: 1) For hot water extraction in temperature range of 60~100$^{\circ}C$ for 4 hours, the higher temperature resulted higher yields in solids and protein. 2) Optimum sea tangle hot water extraction condition were 60~65$^{\circ}C$ for 1 hour which was cheap operating cost and high yield of good taste components. 3) The membrane flux was more higher GR 51 PP. and increase of flow rate permeate flow rate was accordingly increased. but limiting flow volume was 3.7 l/min. 4) It was found that ultration was relatively of higher recovery rate, solid and taste components, and low rejection coefficient rate than diafiltration.

  • PDF

모세관 사이폰 현상을 이용한 부유물질 제거 - 상수처리공정 적용 가능성 평가 - (Suspended Solid Removal using Capillary-syphon Phenomenon -Evaluation of Possibility for Adapting Water Supply Process-)

  • 박동근;김수정;이해군;장정국;한기백;김창원
    • 대한환경공학회지
    • /
    • 제22권7호
    • /
    • pp.1285-1294
    • /
    • 2000
  • 본 연구는 모세관 사이폰 현상을 이용한 부유물질제거 장치를 사용하여 부유물질제거 가능성 및 처리수량과 수질에 미치는 영향인자에 대하여 검토하였다. 처리유량은 누적처리시간과 모세관 사이폰 유입부 수두가 클수록 작아지는 반면에 처리수 수질은 향상되는 경향을 보였다. 한계 flux를 $107{\ell}/m/day$로 하고, 응집제를 각각 0, 0.45, $1.82mg/{\ell}$ (as $Al^{+3}$)로 주입하였을 때 처리수 탁도는 평균 2, 1, 0.5NTU를 보였고, 15~17일간 운전하는 동안 세척수량은 처리수량의 약 0.5~0.7%가 사용되었다. 따라서, 모세관 사이폰 현상을 이용한 부유물질제거 장치는 정수처리공정 중의 응집침전과 급속여과공정에 적용할 수 있을 것으로 기대된다.

  • PDF

침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구 (Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring)

  • 신동환;백병도;장인성
    • 대한환경공학회지
    • /
    • 제30권9호
    • /
    • pp.948-954
    • /
    • 2008
  • 침지형 MBR 공정에서 막 오염과 플럭스 감소의 주요 원인인 케이크층에 의한 저항을 저감하기 위하여 분리막 모듈의 외부에 원통형 관을 도입하였다. 도입된 원통형관 안에 노즐과 산기관을 적용하여 공기 주입량에 따른 공기와 액체의 2상흐름(Two phase flow)중 slug 흐름을 유도하여 공기 방울에 의한 막세정의 효과를 비교 분석하였다. 실험결과 동일한 유량의 공기를 공급할 경우 노즐에서 발생한 공기방울이 원통형관으로 유입되면서 효율적인 slug 흐름을 형성으로 산기관을 사용한 공급 방식보다는 막오염 방지에 효과적이었음을 알 수 있었다. 그러나 노즐로 공급되는 공기의 유량을 최적화하지 않는다면 원통형 관의 벽 부분부터 활성슬러지 혼합액이 퇴적하게 되거나 막간에 슬러지가 퇴적되어 관 내부의 급격한 막힘 현상이 발생하여 일정시간이 경과하면, 오히려 산기관보다 급격한 막오염 현상을 나타냄을 알 수 있었다. 또한 원통형 관 내부에 침지된 분리막의 면적의 최적 비율, A$_m$/A$_t$가 비율이 존재하는 것을 확인할 수 있었다. 산기관의 경우에는 A$_m$/A$_t$ 비율이 0.27일 때 최소화된 막오염이 관찰된 반면에, 노즐의 경우에는 A$_m$/A$_t$ 비율이 0.55일 때 막오염이 최소값을 보였다. 따라서 상승하는 공기방울에 의한 막오염 저감효과는 관 내부의 중공사막이 차지하고 있는 비율, A$_m$/A$_t$에 크게 의존하고 있으며, 산기관과 노즐의 경우 그 최적비율은 각각 다름을 알 수 있었다.