• Title/Summary/Keyword: Limited Storage Capacity

Search Result 122, Processing Time 0.043 seconds

Implementation of Information Access Embedded System for the Blind People (시각 장애인을 위한 정보접근 임베디드 시스템의 구현)

  • Kim, Si-Woo;Lee, Jae-Kyun;Lee, Chae-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2C
    • /
    • pp.167-172
    • /
    • 2008
  • Since a 2-dimensional (2D) bar code can retrieve data and information quickly, it is widely used and recognized as a useful tool for many industrial applications. However, the information capacity of the 2D bar code is still limited. Recently the analog-digital code (AD code), which has the largest storage capacity yet contained in a code, has been developed, thereby expanding the bar code's application range because it overcomes the limitation of data capacity. In this paper, we present the AD code and implement an effective embedded system which can transform text information into voice using the 2D AD code and Text To Speech (TTS). This voice information can also be transmitted to blind people as well as the old by capturing the AD code on paper or in books.

Technology for AR Dry Storage of Spent Fuel (원전부지내 사용후핵연료 건식저장기술 분석)

  • Lee, Heung-Young;Yoon, Suk-Jung;Lee, Ik-Hwan;Seo, Ki-Seog
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.313-327
    • /
    • 1996
  • As an at-reactor(AR) storage method o( spent fuel, there are horizontal concrete module type, metal storage cask type, concrete storage cask type, dual purpose (transportation and storage) cask type and multi-purpose (transportation, storage and disposal) cask type. All other types except multi-purpose one have been already used for AR dry storage of spent fuels after obtaining operation license in various foreign countries. Also the development of multi-purpose type has been continued for operation license. In America, Japan, Germany, Canada, Spain, Switzerland, and Czech Republic, etc., AR dry storage facilities are under operation or on propulsion, and spent fuels are transported to interim storage facility or reprocessing plant after dry storage at reactor temporarily. At Wolsung site, in case of Korea, concrete silo type has already been introduced, and it is believed to be inevitable to store spent fuels at reactor temporarily, considering the reality that storage capacity of spent fuel is approaching to the limit in some nuclear power plants. In this report, the system characteristics, design requirements, technical standards and status of AR storage system, which is suitable for domestic site such as Kori, have been studied. In most cases, the licensed period of storage cask is limited up to 20 years and the integrity of material and maintenance of leaktightness are required during the whole service life.

  • PDF

Clustering-Based Mobile Gateway Management in Integrated CRAHN-Cloud Network

  • Hou, Ling;Wong, Angus K.Y.;Yeung, Alan K.H.;Choy, Steven S.O.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.7
    • /
    • pp.2960-2976
    • /
    • 2018
  • The limited storage and computing capacity hinder the development of cognitive radio ad hoc networks (CRAHNs). To solve the problem, a new paradigm of cloud-based CRAHN has been proposed, in which a CRAHN will make use of the computation and storage resources of the cloud. This paper envisions an integrated CRAHN-cloud network architecture. In this architecture, some cognitive radio users (CUs) who satisfy the required metrics could perform as mobile gateway candidates to connect other ordinary CUs with the cloud. These mobile gateway candidates are dynamically clustered according to different related metrics. Cluster head and time-to-live value are determined in each cluster. In this paper, the gateway advertisement and discovery issues are first addressed to propose a hybrid gateway discovery mechanism. After that, a QoS-based gateway selection algorithm is proposed for each CU to select the optimal gateway. Simulations are carried out to evaluate the performance of the overall scheme, which incorporates the proposed clustering and gateway selection algorithms. The results show that the proposed scheme can achieve about 11% higher average throughput, 10% lower end-to-end delay, and 8% lower packet drop fractions compared with the existing scheme.

Caching Algorithm for Core Network Offloading in Smallcell Environment (소형셀 환경에서 코어망 오프로딩을 위한 캐시 알고리즘)

  • Jung, So-Yi;Kim, Jae-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.32-38
    • /
    • 2015
  • In this paper, we propose a smallcell local caching algorithm under user's context in smallcell environment. The proposed system reduces traffic to core network and the network cost, but increases it's performance. The proposed algorithm precache suitable files using smallcell's regional characteristics and target's personality. It can adjusts a storage allocation to make effective usage of our limited cache storage capacity. In order to evaluate the performance of the proposed cache algorithm, we define the cache efficiency, the decrement of core network traffic. The simulation results show that the proposed algorithm can improve performance by about 200% compared to existing web cache scheme.

Operating Method of BESS for Providing AGC Frequency Control Service Considering Its Availability Maximization (배터리 가용성 극대화를 고려한 BESS의 AGC 주파수제어 추종운영방안)

  • Choi, Woo Yeong;Yu, Ga Ram;Kook, Kyung Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1161-1168
    • /
    • 2016
  • Battery energy storage system(BESS) attract the attention of the power system operators with its fast response to a disturbance in spite of its limited energy capacity. This paper proposes the operating method of BESS for following the Automatic Generation Control(AGC) frequency control which is centrally distributed by a system operator. As BESS needs to just meet the control requirement from the system operator, it should be able to properly manage the state of charge(SOC) of BESS to be available to control signal. For doing these, the proposed method distributes the control requirement to available batteries in proportion to its SOC. In addition, unavailable batteries are controlled to recover the SOC to an appropriate range, and the recovering power is supplied by available batteries meeting the control requirement. Moreover, the proposed method manages the efficiency of power conversion system (PCS) by limiting the number of PCS to be assigned for the low control requirement. Finally, the case studies are carried out to verify the effectiveness of proposed strategy.

Domain decomposition for GPU-Based continuous energy Monte Carlo power reactor calculation

  • Choi, Namjae;Joo, Han Gyu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2667-2677
    • /
    • 2020
  • A domain decomposition (DD) scheme for GPU-based Monte Carlo (MC) calculation which is essential for whole-core depletion is introduced within the framework of the modified history-based tracking algorithm. Since GPU-offloaded MC calculations suffer from limited memory capacity, employing DDMC is inevitable for the simulation of depleted cores which require large storage to save hundreds of newly generated isotopes. First, an automated domain decomposition algorithm named wheel clustering is devised such that each subdomain contains nearly the same number of fuel assemblies. Second, an innerouter iteration algorithm allowing overlapped computation and communication is introduced which enables boundary neutron transactions during the tracking of interior neutrons. Third, a bank update scheme which is to include the boundary sources in a way to be adequate to the peculiar data structures of the GPU-based neutron tracking algorithm is presented. The verification and demonstration of the DDMC method are done for 3D full-core problems: APR1400 fresh core and a mock-up depleted core. It is confirmed that the DDMC method performs comparably with the standard MC method, and that the domain decomposition scheme is essential to carry out full 3D MC depletion calculations with limited GPU memory capacities.

The Probabilistic Production Simulation with Energy Limited Units Using the Mixture of Cumulants Approximation (에너지 제약을 갖는 발전기를 고려한 경우의 Mixture of Cumulants Approximation법에 의한 발전시뮬레이션에 관한 연구)

  • 송길영;김용하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1195-1202
    • /
    • 1991
  • This paper describes a newly developed method of production simulation by using the Mixture of Cumulant Approximation (MOCA). In this method, the load is modelled as random variable (r.v.) which can be interpreted in terms of partitioning the load into various categories. We can consider the load shape of multi-modal characteristics. The number of load category and demarcation points of each load category are calculated automatically by using interpolation and least square method. Each generating unit of a supply system is modelled as r.v. of unit outage capacity according to the number of unit outage subset. Since the computation burden of each subset's moments increases exponentially as units are convolved to the system, we further derive the specific recursive formulae. In simulating the energy limited units, hydro unit simulation is performed using Energy Invariance Property and the simulation of pumped storage unit is modelled as compulsory and economic operations. The proposed MOCA method is applide to the test systems and the results are compared with those of cumulant and Booth Baleriaux method. It is verified that the MOCA method is considerably reliable and stable both pathological and well behaved system.

Web Proxy Cache Replacement Algorithms using Object Type Partition (개체 타입별 분할공간을 이용한 웹 프락시 캐시의 대체 알고리즘)

  • Soo-haeng, Lee;Sang-bang, Choi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.5C
    • /
    • pp.399-410
    • /
    • 2002
  • Web cache, which is functionally another word of proxy server, is located between client and server. Web cache has a limited storage area although it has broad bandwidth between client and proxy server, which are usually connected through LAN. Because of limited storage capacity, existing objects in web cache can be deleted for new objects by some rules called replacement algorithm. Hit rate and byte-hit rate are general metrics to evaluate replacement algorithms. Most of the replacement algorithms do satisfy only one metric, or sometimes none of them. In this paper, we propose two replacement algorithms to achieve both high hit rate and byte-hit rate with great satisfaction. In the first algorithm, the cache is appropriately partitioned according to file types as a basic model. In the second algorithm, the cache is composed of two levels; the upper level cache is managed by the basic algorithm, but the lower level is collectively used for all types of files as a shared area. To show the performance of the proposed algorithms, we evaluate hit rate and byte-hit rate of the proposed replacement algorithms using the trace driven simulation.

High Power Energy Harvesting Systems for IoT Sensor Nodes Systems (IoT 센서노드 시스템을 위한 고출력 에너지 하베스팅 시스템)

  • Kim, Yongseok;Park, Yong Su;Baek, Donkyu
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.4
    • /
    • pp.29-36
    • /
    • 2022
  • Existing IoT sensor nodes operate by receiving energy from a battery. But due to the characteristics of sensor nodes that are widely distributed for collecting various information, there is a disadvantage that the battery needs to be periodically replaced. In order to overcome this disadvantage, energy can be harvested from sunlight or high-temperature steam through an energy harvesting system. However, since the harvested power is quite limited, it is difficult to use applications that require instantaneous high power such as communication. We propose the design of the high-power energy harvesting system where a switch control unit compensates for the limited harvested energy with the energy storage device such as a capacitor. To verify the proposed system, an energy harvesting system based on sunlight was implemented, and we confirmed the maximum supply power to the application and the maximum supply time according to capacity of the energy storage device.

Estimation of Dynamic Properties of Steel Liquid Storage Tank by Shaking Table Test (진동대 실험에 의한 강재 액체저장탱크의 동특성 분석)

  • Choi, Hyoung Suk;Park, Dong Uk;Kim, Sung Wan;Kim, Jae Min;Baek, Eun Rim
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.153-161
    • /
    • 2017
  • Liquid storage tank is one of the major infrastructures and generally used to store gases, drinking and utilizing water, dangerous fluids, fire water and so on. According to the recent reports and experiences, the tank structures are damaged in many earthquakes due to their low energy dissipating capacity. Therefore, many researchers have been tried to know the dynamic properties of the tanks including liquids. However, vary limited experimental studies are carried out using relatively small tank models. In this study, a series of shaking table tests are performed with maximum 2 m cubic rectangular liquid storage tanks made of steel to measure the natural frequency and estimate damping coefficient of impulsive and convective mode of the tanks. Especially, the damping values under different shapes and excitation methods are estimated by logarithmic decrement method and half power band-pass method and compared with current design code and standards such as ASCE 7, Eurocode 8 and NZS. Test results show that the impulsive mode damping is around 2% which is proposed by general standards and codes but the impulsive mode damping is 0.13% average that is slightly lower than the code recommendation.