• 제목/요약/키워드: Limited Current

검색결과 2,694건 처리시간 0.028초

Focal Spinal Nondisjunction in Primary Neurulation : Limited Dorsal Myeloschisis and Congenital Spinal Dermal Sinus Tract

  • Wong, Sui-To;Pang, Dachling
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권2호
    • /
    • pp.151-188
    • /
    • 2021
  • Spinal dysraphic lesions due to focal nondisjunction in primary neurulation are commonly encountered in paediatric neurosurgery, but the "fog-of-war" on these conditions was only gradually dispersed in the past 10 years by the works of the groups led by the senior author and Prof. Kyu-Chang Wang. It is now clear that limited dorsal myeloschisis and congenital spinal dermal sinus tract are conditions at the two ends of a spectrum; and mixed lesions of them with various configurations exist. This review article summarizes the current understanding of these conditions' embryogenetic mechanisms, pathological anatomy and clinical manifestations, and their management strategy and surgical techniques.

An Enhanced Finite-Settling-Step Direct Torque and Flux Control (FSS-DTFC) for IPMSM Drives

  • Kim, Sehwan;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1367-1374
    • /
    • 2016
  • This paper presents a discrete-time version of voltage and current limited operation using an enhanced direct torque and flux control method for interior permanent magnet synchronous motor (IPMSM) drives. A command voltage vector for airgap torque and stator flux regulation can be uniquely determined by the finite-settling-step direct torque and flux control (FSS-DTFC) algorithm under physical constraints. The proposed command voltage vector trajectories can be developed to achieve the maximum inverter voltage utilization for the discrete-time current limit (DTCL)-based FSS-DTFC. The algorithm can produce adequate results over a number of the potential secondary upsets found in the steady-state current limit (SSCL)-based DTFC. The fast changes in the torque and stator flux linkage improve the dynamic responses significantly over a wide constant-power operating region. The control strategy was evaluated on a 900W IPMSM in both simulations and experiments.

PSCAD/EMTDC를 이용한 불평형 부하에서의 초전도 케이블의 운전특성 해석 (A Operated Characteristic Analysis of HTS Cable in Unbalanced Load Using PSCAD/EMTDC)

  • 이현철;황시돌;이근준
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1713-1719
    • /
    • 2008
  • A high temperature superconducting power cable (HTS power cable) was applied large current capacity by no resistance in normal state. Fault state was risen out of over-current but, it was limited to resistance. This study was modeling equivalence, and unbalanced state analyzed operating characteristic of HTS power cable. The equivalence model was composed superconductor, shield, and former part. This model simulation was appeared conductor and shield current in normal state, but unbalanced state was appeared former current as rise current by resistance. So it need to sufficiently influenced the quench characteristic when the former design.

배전변전소에 대용량변압기로 교체 적용시 보호협조를 위한 초전도 전류제한기의 임피던스 분석 (Analysis on SFCL's Impedance for Protective Coordination in Large Transformer installed in Distribution Substation)

  • 김진석;김명후;류일경;문종필;임성훈;김재철;안재민
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1479-1484
    • /
    • 2009
  • The introduction of the large transformer due to the large power demand has increased the fault current in power distribution system. The increased fault current can exceed the cut-off ratings of the circuit breaker. As the methods to solve this problem, the superconducting fault current limiter(SFCL) has been notified. However, the limited fault current by SFCL affects the operational characteristics of the protective device such as overcurrent relay. Therefore, the selection of the proper impedance for the SFCL is required to keep overcurrent relay's protective coordination with the SFCL when a large transformer is introduced into the distribution system. In this paper, the SFCL's impedance for protective coordination was investigates in that a large transformer is introduced.

스피커의 특성을 고려한 음향 전력 증폭기 구동 방식의 비교: 전압 구동 방식과 전류 구동 방식 (Comparison of the Driving Modes of an Audio Power Amplifier Considering the Characteristics of the Loudspeaker: Voltage Drive vs. Current Drive)

  • 은창수;이유칠
    • 한국멀티미디어학회논문지
    • /
    • 제20권9호
    • /
    • pp.1551-1558
    • /
    • 2017
  • Audio power amplifiers have been designed based on the premise that the impedance of loudspeakers is fixed at nominal 4 ohms or 8 ohms. However, it is known that the impedance varies with frequency and takes on the nominal value at some limited frequencies. The principle of the loudspeaker operation reveals that the sound pressure produced by the loudspeaker is proportional to the current flowing in the voice coil, not the voltage between the two terminals. We take the characteristics of the loudspeaker into account and compare the frequency responses of the loudspeaker in voltage-drive mode and current-drive mode via computer simulations, to conclude that the audio amplifier drive mode should be re-considered in an effort to improve the sound quality.

이중밴드 히스테리시스 전류 제어 방식 (A Double Band Hysteresis Current Control Method)

  • 오원현;유창훈;신은철;박성민;노학엽;유지윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.579-583
    • /
    • 2003
  • Hysteresis controllers are intrinsically robust to system parameters, exhibit very high dynamic response and are suitable for simple implementation. But the current control using a conventional hysteresis controller has the disadvantage that high switching frequency may happen due to lack of coordination among individual hysteresis controllers of three phases. This will of course increase the switching loss. In addition, the current error is not strictly limited. So, in this paper to reduce the switching frequency, a double band hysteresis current controller is proposed. The presented control system was tested with digital simulation in the Borland C++ program and demonstrate the advantage of proposed hysteresis current controller.

  • PDF

MODELING OF A REPULSIVE TYPE MAGNETIC BEARING FOR FIVE AXIS CONTROL INCLUDING EDDY CURRENT EFFECT

  • Ohji, T.;Mukhopadhyay, S.C.;Iwahara, M.;Yamada, S.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.625-629
    • /
    • 1998
  • So far a single-axis controlled repulsive type magnetic bearing system have been designed and fabricated in our laboratory employing the repulsive forces operating between the stator and rotor permanent magnet for levitation. The radial axis is uncontrolled passive one. The higher speed of operation is limited due to the vibration along the uncontrolled axis and the increase of control current due to eddy current interference. This paper will discuss a detailed modeling of the repulsive type magnetic bearing system for five axis control including the eddy current effect and the method of reduction of eddy current effect. Simulation results using Matlab will be presented.

  • PDF

전류측정감도 개선을 위한 로고우스키 코일의 설계 (Design of Rogowski coil to improve of current measurement sensitivity)

  • 박정남;이청;장용무;강성화;임기조;나동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.609-612
    • /
    • 2001
  • Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents. and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore. geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error was examined as well. In the results, the source of error was associated with coil designs. i.e. shape and uniformity of coil and a geometrical location of current source inside and outside of the Rogowski coil.

  • PDF

선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구 (A study on operating properties of superconducting fault current limiter in the line-to-line fault)

  • 최효상;현옥배;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

고온 초전도 한류퓨즈의 동작특성 (Operation properties of high $T_c$ superconductive current limiting fuse)

  • 최효상;현옥배;김혜림;황시돌;박권배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.67-68
    • /
    • 2001
  • We present the basic properties of a superconductive current limiting fuse (SCLF) based on YBCO/Au films. The SCLF consists of meander type YBCO stripes covered with an Au layer for current shunt. The fault current was first limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enables the SCLF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption.

  • PDF