• Title/Summary/Keyword: Limit equilibrium

Search Result 377, Processing Time 0.022 seconds

A Study on Change of Safety Factor according to Slope Analysis Method using Strength Parameters and Slope Change (강도 정수와 경사도 변화를 활용한 비탈면 해석기법에 따른 안전율 변화에 관한 연구)

  • Moon, Hyojong;Shim, Jeonghoon;Jeong, Jisu;Lee, Seungho
    • The Journal of Engineering Geology
    • /
    • v.27 no.1
    • /
    • pp.31-40
    • /
    • 2017
  • The slope stability analysis by the limit equilibrium method has the disadvantage that it can be applied only when the analysis is performed by setting the critical plane after analyzing the active surface many times and the soil is uniform and only the safety factor can be calculated. However, the analysis using the strength reduction analysis method has advantages that the engineer can judge various aspects and calculate the safety factor. In this study, the safety factor according to the change of slope and shear strength was compared and analyzed using limit equilibrium analysis and strength reduction method. It is suggested that it is desirable to use the strength reduction method which can synthetically review the stress, displacement, and strain in the soil.

An Assessment of Safety Factor for Tunnels Excavated in a Weak Rock Layer (연약 암반층에 굴착된 터널의 안전율 평가)

  • You, Kwang-Ho;Park, Yeon-Jun;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.3
    • /
    • pp.47-57
    • /
    • 2000
  • It is difficult to calculate factor of safety of a tunnel by applying any analytical method based upon limit equilibrium method since the shape of failure plane in tunnel analysis can not be easily assumed in advance. To cope with this shortcoming, a method is suggested to calculate safety factor of a tunnel by numerical analysis using strength reduction technique. A circular tunnel excavated in a homogeneous rock was selected as an example problem and factors of safety were calculated for no-supported, partly-supported, and completely-supported cases respectively. Meshes with 3 different sizes were examined for a sensitivity analysis. For the verification of the proposed method, a limit equilibrium analysis was conducted and compared with the numerical analysis. The proposed method herein can be used to calculate factor of safety of a tunnel regardless of tunnel shape or geological conditions, and thus can contribute for the improved design and stability assessment of tunnels.

  • PDF

Analysis of Talus Slope Stability using 2D FEM and 3D Limit Equilibrium Method (2차원 유한요소법과 3차원 한계평형법을 이용한 테일러스 사면안정성 해석)

  • Lee, Kyoung-Mi;Kim, Sung-Kwon;Seo, Yaung-Seok;Lee, Sun-Bok;Kim, Dong-Hyun;Kim, Do-Sik
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.381-391
    • /
    • 2007
  • A series of talus slope stability analyses were carried out using 2D FEM and 3D limit equilibrium methods for this study. The FEM analyses on Phase 2 were performed to delineate failure depths based on stress distributions for each slope. The results revealed that the failure surface exist in the colluvium layer of about 3-10 m thickness. Three dimensional models, derived from the FEM analyses and geological field survey, were made for the use in a 3D limit equilibrium analysis. The result shows that all the talus slopes are stable under dry condition, but unstable under saturated condition due to heavy rain.

Reinforcing Effect of a Soil Nailing on Plane Failure of a Slope by Comparing Finite Difference Analysis with Limit Equilibrium Analysis (유한차분해석과 한계평형해석의 비교를 통한 평면파괴 사면 쏘일네일링 보강효과 연구)

  • You, Kwang-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.11
    • /
    • pp.5-15
    • /
    • 2014
  • It is very important to design and construct slopes safely because damage cases are increasing due to slope failure. Recently, Limit Equilibrium Method (LEM) based programs are commonly used for slope designs. Though LEM can give factors of safety through simple calculation, it has a disadvantage that the sliding surface should be assumed in advance. On the other hand, the use of Finite Difference Method (FDM) is increasing since the factor of safety can be easily estimated by using shear strength reduction technique. Therefore the purpose of this study is to present a reasonable slope design methodology by comparing the two commonly used analysis approaches; LEM and FDM. To this end, the reinforcement effects of the two methods were compared in terms of the support pattern of soil nailing reinforced in the section where plane failure is anticipated. As a result, the reinforcement effects by nail angle and nail spacing turned out to be equal. Also it was found that the factor of safety increased in LEM, but not changed in FDM when the nail length increased.

Behavior of Geotextile Tube Composite Structure by 2-D Limit Equilibrium and Plane Strain Analysis (2차원 한계평형 및 평면변형해석을 통한 지오텍스타일 튜브 복합구조물의 거동분석)

  • Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.13-22
    • /
    • 2006
  • The geotextile have been used in filtration and drainage for over 30 years in many applications of civil and environmental projects. Geotextile tube is compound technology of filtration and drainage property of geotextile. Geotextile have been used for various types of containers, such as small hand-filled sandbags, 3-dimensional fabric forms for concrete paste, large soil and aggregate filled geotextile gabion, prefabricated hydraulically filled containers, and other innovative systems involving containment of soils using geotextile. They are hydraulically filled with dredged materials. It have been applied in coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. This paper presents the behavior of geotextile tube composite structure by 2-D limit equilibrium and plane strain analysis. 2-D limit equilibrium analysis was performed to evaluate the stability of geotextile tube composite structure for the lateral load and also the plane strain analysis was conducted to determine the design and construction factors. Based on the results of this paper, the three types of geotextile tube composite structure is stable. And the optimum tensile strength of geotextile is 151kN/m and maximum pumping pressure is 22.7kN/m.

  • PDF

Stability Behavior of Geotextile Tube Composite Structure by Slope Stability and 2-D Limit Equilibrium Analysis (2차원 한계평형 및 사면안정해석을 통한 지오텍스타일 튜브 복합구조물의 안정성 분석)

  • Oh, Young-In;Shin, Eun-Chul;Kang, Jeong-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.4
    • /
    • pp.11-18
    • /
    • 2006
  • Geotextile has been used for various types of containers, such as small hand-filled sandbags, 3-dimensional fabric forms for concrete paste, large soil and aggregate filled geotextile gabion, prefabricated hydraulically filled containers. They are hydraulically filled with dredged materials and have been applied in coastal protection and scour protection, dewatering method of slurry, temporary working platform for bridge construction, temporary embankment for spill way dam construction. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. The paper presents the stability behavior of geotextile tube composite structure by 2-D limit equilibrium and slope stability analysis. 2-D limit equilibrium analysis was performed to evaluate the stability of geotextile tube composite structure to the lateral earth pressure and also transient seepage and stability analysis were conducted to determine the pore pressure distribution by tide variation and slope stability. Based on the results of this paper, the three types of geotextile tube composite structure is stable and also slope stability of overall geotextile tube composite structures is stable with the variation of tidal conditions.

  • PDF

The Short-term Safety Factor Considering Passive Resistance Effect of Bar Anchor Based on Smart Construction (스마트 건설기반의 강봉앵커 수동저항 효과를 고려한 단기 안전율)

  • Donghyuk Lee;Duhyun Baek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.4
    • /
    • pp.29-35
    • /
    • 2024
  • This is an analytical study to confirm the passive resistance effect before post-tensioning of steel bar anchors. When using a steel bar as a permanent anchor, if displacement occurs within the slope even before the head load is applied, the displacement is suppressed by the passive resistance caused by the interaction between the steel bar, grout, and surrounding soil. Accordingly, the shape of the failure surface and changes in the safety factor were examined using limit equilibrium analysis and finite element analysis targeting sites where steel bar anchors were actually applied. It was found that the safety factor of the slope reinforced with steel bar anchors is 2.02 using finite element analysis, which is about 5.9% smaller than 2.14 using limit equilibrium analysis. Also, the location of the failure surface was found to be deeper compared to the unreinforced slope. Likewise, the factor of safety has a 153% and 163% increase using finite element method and limit equilibrium analysis, respectively. In addition, the maximum displacement occurs in the lower unreinforced section within the slope, and the displacement is found to be reduced by 42 to 83% at the location where the steel bar anchors are installed.

New Plastic Limit Load Equations of Pipes with Inner and Outer Circumferential Surface Cracks Considering Thickness Effect (내부 및 외부 원주방향 표면균열이 존재하는 배관의 두께효과를 고려한 소성한계하중 계산식 제시)

  • Kim, Yeon-Soo;Huh, Nam-Su
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.2
    • /
    • pp.71-80
    • /
    • 2019
  • In this study, limit load equations of thick-walled pipes with inner and outer circumferential surface cracks were derived based on force and moment equilibrium conditions. Since the limit load equations based on the mean radius at uncracked ligament, previously proposed by Kanninen et al., are based on the premise that the pipe wall thickness is relatively thin, the existing limit load solutions are only applicable to thin-walled pipes. In order to analyze the effect of the pipe thickness and surface crack depth on the limit load results, the predictions using the present limit load equations are compared with those using the existing solutions for thin-walled pipes. Being derived considering the thickness effect, the limit load solutions from this paper are believed to be more accurate for thick-walled pipes than the limit load equations presented for thin-walled pipes, and thus to be valuable equations for integrity assessment of thick-walled pipes.