• Title/Summary/Keyword: Limit Load Method

Search Result 461, Processing Time 0.027 seconds

Reliability-Based Assessment of Safety and Load Carrying Capacity of Steel-Box Pedestrian Bridges (신뢰성에 기초한 강상형 보도육교의 안전도 및 내하력 평가)

  • 조효남;최영민;이은철
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.189-201
    • /
    • 1997
  • A number of standard type of steel-box pedestrian bridges are constructed in th metropolitan high way or heavy traffic urban area. Although it has the advantage of speedy construction because of its simple structural form and prefabricated erection method, it has been reported that many of these bridges are deteriorated or damaged and thus are in the state such that it would give unsafe and uncomfortable feeling to pedestrians. In the paper, for the realistic assessment of safety and load carrying capacity of deteriorated and/or damaged steel box pedestrian bridges, an interactive non-linear limit state model is formulated based on the von Mises' combined stress yield criterion. It has been demonstrated that the proposed model is effective for the reliability-based safety assessment and load carrying capacity evaluation of steel-box pedestrian bridges. In addition, this study suggests an effective and practical field load test method for pedestrian bridges.

  • PDF

A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems (복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구)

  • Hyunock Jang;Ilyoung Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.329-338
    • /
    • 2024
  • Purpose: This study verified the safety of the improved box-type girder behavior by comparing and evaluating the bending behavior results of a full-scale specimen based on the analytical behavior of the splice element PSC U-shaped girder with integrated tensioning systems. Method: Based on the results of the service and strength limit state design using the bridge design standard(limit state design method), the applied load of a 40m full-scale specimen was calculated and a static loading experiment using the four-point loading method was performed. Result: When the design load, crack load, and ultimate load were applied, the specimen deflection occurred at 97.1%, 98.5%, and 79.0% of the analytical deflection value. When the design load, crack load, and ultimate load were applied, the crack gauge was measured at 0.009~0.035mm, 0.014~0.050mm, and 6.383~5.522mm at each connection. Conclusion: The specimen behaved linear-elastically until the crack load was applied, and after cracks occurred, it showed strainhardening up to the ultimate load, and it was confirmed that the resistance of bending behavior was clearly displayed against the applied load. The cracks in the dry joints were less than 25% of grade B based on the evaluation of facility condition standard. The final residual deformation after removing the ultimate load was 0.114mm, confirming the stable behavior of the segment connection.

A Design of Homopolar Generator System Considering Instability with Negative Characteristics Load (부성부하와의 발진을 고려한 단극발전기 시스템 설계)

  • Kim, In-Soo;Seong, Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.449-451
    • /
    • 2008
  • This paper studies the instability between homopolar generator and constant power load with negative impedance characteristics, provides the design method of homopolar generator system which overcomes the instability. In case of magnitude and phase of impedance of source and load mismatch, control instability of source can occur. For the safety of phase of load impedance, the gain of P, I controller with sufficient phase margin is applied through analysis on the simulation model of generator system, and the gain limit of load impedance is ensured by limitation of the gain margin of generator system. The stability of power system can be increased by considering and analyzing the impedance of source and load.

  • PDF

Analysis of Bridge Inverter Circuit (브리지 인버어터 회로의 해석)

  • 박준열
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.3
    • /
    • pp.30-34
    • /
    • 1978
  • A bridge inverter circuit with a paralled resonant circuit load is analyzed. The approach to the circuit analysis leads to reasonable reality. The limit of trigger frequency, the range of SCR turn-off time, the peak capacitor voltage and the relation between the load current and trigger rate are derived for the suitable design criteria. Numerical method is used for calculation of transcendental equation.

  • PDF

A Study on the Fatigue Behavior of Spot Weld Specimen as Applied Load Pattern (하중작용방식에 따른 점용접재의 피로거동)

  • 송삼홍;양윤진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.485-488
    • /
    • 2000
  • In this study, the fatigue characteristic of spot weld specimen was studied by using the various specimen. The specimen types were tensile shear specimen welded one spot and two spot, and cross tension. The tensile tests and fatigue tests were executed to know the mechanical properties under static and fatigue load condition. In addition, the relationship was illustrated by finite element method.

  • PDF

The study on characterization of current limit and fabrication of device for current limit formed by thick film (후막형 전류제한소자제작과 전류제한특성 연구)

  • Lim, Sung-Hun;Kang, Hyeong-Gon;Choi, Myung-Ho;Han, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1704-1706
    • /
    • 1999
  • $YBa_2Cu_3O_x$ superconducting thick film was fabricated by surface diffusion process of $Y_2BaCUO_5$ and the mixed compound of $(3BaCuO_2+2CuO)$ expected to be liquid phase above the peritectic temperature of YBa2Cu30x. For the surface diffusion. 3BaCu02+2CuO mixed with binder material was patterned on $Y_2BaCuO_5$ substrate by the screen printing method. The characteristic of current limit on thick film fabricated was measured. The thick film limited the current from $2.8213mA_{rms}$ to $4.2034mA_{rms}$ with $500{\Omega}$ load resistance, and from $4.1831mA{rms}$ to $4.2150mA_{rms}$ with $10{\Omega}$ load resistance.

  • PDF

A study on reduction of pre-crack deviation in CTOD specimen using reverse bending method (Reverse Bending을 통한 CTOD 시험 예비균열 형상균일화에 관한 연구)

  • Jeong, Sehwan;Park, Dong-Hwan;Kim, Hyeon-Su;Shin, Sang-Beom;Park, Tae-Jong
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.62-68
    • /
    • 2015
  • This study investigates the appropriate range of reverse bending load for the CTOD test of thick weld by observing improvement of pre-crack shape and determination of the limit applicable load. In order to do it, the effect of the amount of the reverse bending load on the maximum deviation of the pre-crack length was investigated by the extensive tests, and the variation of plastic zone size in way of the crack tip under reverse bending load were evaluated by FEA. With the results obtained by the experiments and FEA, the proper range of reverse bending load was suggested. The effectiveness of the reverse bending method was verified by examining the pre-crack straightness after CTOD tests of thick weld specimens with various thickness and strength.

Improved Method of Maximum Loadability Estimation in Power Systems By Transforming the Distorted P-e Curve (왜곡된 P-e곡선의 변환에 의한 전력계통 최대허용부하의 향상된 추정 방법)

  • Hwang, Ji-Hwan;Choi, Byoung-Kon;Cho, Byoung-Hoon;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.363-365
    • /
    • 2000
  • This paper presents an improved method to estimate the maximum load level for heavily loaded power systems with the load-generation variation vector by using the elliptic pattern of the P-e curve. The previous study suggested a simple technique of removing e-f coupling, where only high voltage load flow solutions to calculate transforming angle of system reference is needed. The proposed algorithm is improved to require only one load flow solution at a specific load level in addition to the operating point at the beginning stage, which reduces the computation time and the iteration number of estimation. The proposed method can be efficiently applied to heaviIy loaded systems with the combination of CPFlow when the reactive power limit and ULTC are considered. In this paper, the effect of ULTC on the estimation of maximum loadability index is also investigated. The proposed algorithm is tested on New England 39 bus system and IEEE 118 bus system.

  • PDF

Nonlinear analysis of the RC structure by higher-order element with the refined plastic hinge

  • IU, C.K.
    • Computers and Concrete
    • /
    • v.17 no.5
    • /
    • pp.579-596
    • /
    • 2016
  • This paper describes a method of the refined plastic hinge approach in the framework of the higher-order element formulation that can efficaciously evaluate the limit state capacity of a whole reinforced concrete structural system using least number of element(s), whereas the traditional design of a reinforced concrete structure (i.e. AS3600; Eurocode 2) is member-based approach. Hence, in regard to the material nonlinearities, the efficient and economical cross-section analysis is provided to evaluate the element section capacity of non-uniform and arbitrary concrete section subjected to the interaction effects, which is helpful to formulate the refined plastic hinge method. In regard to the geometric nonlinearities, this paper relies on the higher-order element formulation with element load effect. Eventually, the load redistribution can be considered and make full use of the strength reserved owing to the redundancy of an indeterminate structure. And it is particularly true for the performance-based design of a structure under the extreme loads, while the uncertainty of the extreme load is great that the true behaviour of a whole structural system is important for the economical design approach, which is great superiority over the conservative optimal strength of an individual and isolated member based on traditional design (i.e. AS3600; Eurocode 2).

Comparison of Design Strands for Safety Factor of Offshore Wind Turbine Foundation (해상 풍력발전기 기초의 안전율에 관한 설계기준 분석 연구)

  • Jang, Hwa Sup;Kim, Ho Sun;Lee, Kyoung Woo;Kim, Mann Eung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2B
    • /
    • pp.149-152
    • /
    • 2012
  • This study is carried out to analyze the design method and safety rate degree for IEC 61400-3, DNV-OS-J101, GL Wind, EUROCODE, AASHTO and domestic design standard used for offshore wind turbine foundation design. The findings will provide a design parameter for domestic offshore wind turbine foundation design. The design of the steel Support Structure of an offshore wind turbine can be based on either the Allowable Stress Design(ASD) approach or the Load and Resistance Factor Design(LRFD) approach. The design principles with the use of LRFD method are described with various limit states. A limit state is a condition beyond which a structure or part of a structure exceeds a specified design requirement. Design by the LRFD method is a design method by which the target component safety level is obtained by applying load and resistance factors to characteristic reference values of loads (load effects)and structural resistance. When the strength design of the steel Support Structure is based on the ASD approach, the design acceptance criteria are to be expressed in terms of appropriate basic allowable stresses in accordance with the requirements specified. After comparison an economics domestic offshore wind turbine foundation standard will be developed.