• 제목/요약/키워드: Lightning impulse test

검색결과 112건 처리시간 0.036초

산업플랜트용 서지 측정 분석 장치 개발 (Development of the Surge Measurement System for Low Voltage Power Line of Industrial Plants)

  • 김영진;김재형;장석훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1698-1699
    • /
    • 2007
  • This paper deals with the surge measurement system for low voltage power line of industrial plants. It consists of a capacitive divider, A/D conversion part, signal processing and control part. A FPGA and a DSP board were designed to fast signal processing and control. Also, in order to measure lightning surge and switching surge for a long time, data backup device was applied by using SD memory. A performance of the measurement system was verified through evaluation test using impulse calibration generator.

  • PDF

22.9kV 가공배전선로의 뇌 과전압 모의 및 실측 연구 (An Experimental Study on the Lightning Over-Voltages on 22.9kV Multi-Grounded Overhead Distribution Lines Simulated Using Impulse Current Generator and True-type Test Line)

  • 류희석;정동학;남기영;이재덕;김대경;박상만;정영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.372-374
    • /
    • 2004
  • 22.9kV 가공배전선은 여러 요소들로 구성되기 때문에 뇌격에 대한 반응도 단순하지 않다. 현재의 절연협조는 대표적인 선로모델에 패한 선로상수, 접지저항 등의 대표 값을 사용하여 EMTP로 계산한 뇌충격과전압 값을 근거로 하고 있다. 절연협조 수준에 따라 경제성이 결정되고 계산에 의한 모델해석결과는 실제의 현상과 많은 차이를 나타낼 수 있음에도 불구하고 현재의 기준은 계산과정에서 사용되는 모델과 특성 값의 유효성을 확인하는 수준에 머물고 있다. 이 연구에서는 ICG로 충격전류를 인가하여 여러 가지 경우에 애자 양단에 인가되는 과전압을 실측하였다. 실측 결과 접지특성은 애자에 인가되는 과전압에 많은 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

외부 환경조건에 따른 ZnO 피뢰기의 전기적 특성의 변화 (Changes in Electrical Properties of ZnO Surge Arresters According to Surrounding Conditions)

  • 이승주;이수봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.62-68
    • /
    • 2008
  • 이 논문은 ZnO 피뢰기의 외부환경 변화에 따른 전기적 특성을 기술하였다. 뇌임펄스전류에 의한 ZnO 피뢰기의 열화특성을 분석하기 위해 8/20[${\mu}s$], 2.5[kA]의 임펄스전류를 시료에 인가하였다. ZnO 피뢰기의 누설전류를 다양한 외부 온도와 주수 상태에서 상용 주파수 교류 전압을 인가하여 측정하였다. 그 결과 임펄스전류의 인가횟수와 외부 온도가 증가함에 따라 누설전류가 증가하였고, 누설전류의 비대칭성도 뚜렷하였다. 또한 주수 시험에서 ZnO 피뢰기의 외피를 통하여 흐르는 전류는 피뢰기 소자의 누설전류보다 크게 나타났다. 본 연구의 결과는 피뢰기의 감시시스템 성능과 신뢰성 향상의 요소로 적용할 수 있다.

뇌 임펄스를 이용한 현수애자의 내부결함 검출 (The Inner Defect Detection of Suspension Insulators by Lightning Impulse)

  • 송일근;곽희로
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권6호
    • /
    • pp.83-90
    • /
    • 1995
  • 본 논문에서는 자기체 현수애자 내부의 미세한 결함에 의한 관통사고 원인과 예방책을 제시하고자 PD(Partial Discharge)실험에 사용된 자기체 현수애자의 전계강도를 분석하였고, 상용주파 유중파괴 시험과 급준파 전압시험을 비교, 시험하였다. 이중 시료는 SEM(Scanning Electron Microscope)을 사용해서 단면촬영과 소재의 특성을 분석하였으며, 이종 물질간의 열팽창계수 차이로 인한 사고 진전 가능성이 큰 자기부와 금구류의 접착제로 사용하고 있는 포틀랜드 시멘트에 대하여 오토클래브 팽창도를 시험하였고, 사고 예방을 위한 내부결함 평가방법을 제시하였다.

  • PDF

13.2kV/630A급 고온초전도 한류기의 절연설계 (Insulation Design for a 13.2kV/630A High-Tc Superconducting Fault Current Limiter)

  • 강형구;이찬주;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.941-942
    • /
    • 2007
  • The superconducting fault current limiter (SFCL) consists of superconducting coil for limiting the fault current and cryogenic cooling system for keeping the coil in superconducting condition. The study on the insulation design for superconducting coil and cryogenic cooling system should be elaborately performed to develop a high voltage SFCL. In this paper, insulation design of solenoid coil for 13.2kV/630A SFCL is performed through the AC dielectric breakdown test and lightning impulse dielectric strength test. The dependence of dielectric characteristics on the magnitude of liquid nitrogen pressure is also investigated. Through the investigation, it is verified that dielectric characteristics of sub-cooled nitrogen are strongly enhanced by the pressurization. The electrical insulation design of 13.2kV/630A SFCL is performed by applying the experimental results. The successful insulation design for development of 13.2kV/630A SFCL is confirmed by AC dielectric breakdown tests.

  • PDF

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;이운용;한동희;강성화;최인혁;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성 (Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures)

  • 이복희;백영환;오성균;안창환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.85-90
    • /
    • 2006
  • 본 논문은 불평등 전계의 $SF_6/CO_2$혼합기체 중에서 전구방전특성에 대한 실험결과를 제시한다. 임펄스 전구방전 진전을 코로나 전류와 방전광 이미지의 측정으로 조사하였다. 정 부극성의 전구방전 진전메커니즘은 기본적으로 같았으며, 초기스트리머코로나는 침전극의 끝단에서 발단되어 계단상으로 진전하는 리더에 의해 시험갭을 교락시킨다. 정극성에서 리더펄스의 휴지시간은 부극성에서보다 매우 짧았다. 또한 부극성에서 초기스트리머코로나와 절연파괴사이의 시간간격은 정극성에서보다 매우 길게 나타났다. 정극성에서 방전채널경로는 임의적으로 나타났으며, 부극성에서 리더 채널은 정극성에서 보다 굵고 밝게 나타났다.

RCD와 SPD의 접속 위치에 따른 보호협조 (Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices)

  • 이복희;박희열;신건진;배관영;류춘형;이강희
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.

서지전압에 대한 50[A]용 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages)

  • 이승칠;장석훈;이복희
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권5호
    • /
    • pp.44-52
    • /
    • 1997
  • 반도체와 IC를 포함한 전자회로는 서지 전압 및 전류에 대해 매우 취약하다. 따라서 전자회로와 교류전원선로에 서지보호장치가 널리 사용되고 있다. 이들 서지보호장치의 동작에 의해 누전 차단기가 오동작 할 수 있으며, 누전 차단기의 오동작에 의한 교류전원의 차단은 전자.정보화 시스템의 운전효율 및 신뢰성의 저하와 경제적인 손실 등과 같은 단점을 초래한다. 본 연구의 목적은 서지 전압에 대한 누전 차단기의 오동작 특성을 조사하는 것이다. 10〔kV〕의 1.2/50〔$\mu\textrm{s}$〕서지전압발생기를 제작하였으며, 한국공업규격 KS C 4613의 시험조건과 바리스터를 포함하는 모의 시험회로 조건에 대해 서지 전압을 인가하였을 때 누전 차단기의 오동작 특성을 측정하였다. 그 결과, 서지 전압과 표류정전용량이 증가함에 따라 누전 차단기의 영상전류의 피크값은 증가하였다. 본 연구에서 사용된 모든 누전 차단기는 KS C 4613에 규정된 뇌임펄스 부동작 시험조건에는 적합하였다. 그러나 바리스터를 삽입한 시험회로 조건에서는 단지 1종의 시료를 제외하고 모두 오동작하였다. 서지보호장치를 가지고 있는 교류전원선로에 설치된 누전차단기는 오동작할 가능성이 매우 높다.

  • PDF

An Investigation on Surface Flashover Characteristics of FRP in Several Insulation Gases for the Spacer of Cryogenic Bushing

  • Hwang, Jae-Sang;Shin, Woo-Ju;Seong, Jae-Kyu;Lee, Jong-Geon;Lee, Bang-Wook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.20-23
    • /
    • 2012
  • Superconducting equipment has been actively investigated for securing the environment and energy technology (ET) in various parts of the world. Despite these movements, a high voltage cryogenic bushing, which plays an important role of interconnection between the electric power systems and superconducting devices, has not been fully developed due to severe insulation requirements. A gas insulated cryogenic bushing has been investigated as one of our projects since 2010. As a basic step to obtain the design parameters for cryogenic bushing, we focused on the surface flashover characteristics of glass fiber reinforced plastic (FRP) in several insulation gases. For the surface flashover tests, several insulation gases including $SF_6$, $CF_4$ and $N_2$ gas were prepared. Various length of FRP specimens were fabricated in order to obtain the fundamental data for creepage distance of FRP. The first specimen group was from 2 mm to 10 mm with 2 mm intervals and the second specimen group was from 20 mm to 100 mm with 20 mm intervals. And the gas pressure was varied from 1 bar to 4 bar. An AC overvoltage test and a lightning impulse test were performed. Then the experimental results of surface flashover were obtained and analyzed. Based on these results, it would be possible to design the optimum creepage distance of FRP in a cryogenic bushing.