• 제목/요약/키워드: Lightning impulse breakdown voltage

검색결과 49건 처리시간 0.029초

불평등전극계에서 뇌임펄스전압에 대한 $N_2$기체의 절연파괴 특성 (The breakdown characteristics of $N_2$ gas with lightning impulse voltage in the non-uniform electrode)

  • 이복희;이봉;조정현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents the experimental results on breakdown characteristics in $N_2$ gas under non-uniform electric fields caused by both the positive and negative lightning impulse voltages. $N_2$ gas have an advantage of eco-friendly and cost reduction, and safety aspects. In order to analyze the impulse pre-breakdown processes in $N_2$ gas, we carried out measurements and observations of the impulse breakdown voltages, pre-breakdown current and luminous signals. They were measured by a voltage divider, a shunt and a photo-multiplier tube, respectively. Additionally, the characteristics of discharge channels were observed by high speed cameras. The breakdown voltages in the positive polarity was lower than those in the negative polarity.

  • PDF

$SF_6-N_2$혼합기체 중에서 불평등전계 갭의 임펄스 절연파괴 특성 (Impulse Breakdown Characteristics of Nonuniform Field Gap in SF_6-N_2 Mixtures)

  • 이복희;이경옥;김정일
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.533-540
    • /
    • 2000
  • Lightning impulse $(1.2/44[\mus])$ and damped oscillating impulse $(Osc./44[\mus])$ : 0.83[MHz]) breakdown characteristics in sulphur-hexafluoride/nitrogen (SF6-N2) mixtures were investigated. The predischarge currents were observed to clarify the breakdown mechanism. th experiments were carried out under nonuniform electric fields disturbed by a needle-shaped protrusion whose length and diameter are 10[mm] and 1[mm] at total gas pressure up to 0.5[MPa] with nitrogen concentrations varying from 5 to 20[%] in the mixture. The electrical breakdowns of SF6-N2 mixtures for both the positive and negative polarities develop with steplike pulses in leader mechanism and the breakdown voltage -time (V-t) characteristics were affected by the space charge. The voltage-time curves for the negative oscillating impulse voltage were extended over the longer time range. The minimum breakdown voltages for the negative lightning and oscillating impulse voltage were higher than those for the positive ones. in particular the positive breakdown voltages were independent of the gas pressure.

  • PDF

임펄스전압에 대한 N2가스의 절연파괴특성 (Electrical Breakdown Characteristics of N2 Gas under Impulse Voltages)

  • 신희경;김동규;이복희
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.131-136
    • /
    • 2011
  • This paper aims to examine the possibility of using an environmentally friendly $N_2$ as an alternative gas to $SF_6$. For this purpose, we have investigated breakdown characteristics of $N_2$ under impulse voltages in a quasi-uniform electric field gap. The 1.2/50[${\mu}s$] lightning impulse voltage, switching impulse voltages and oscillatory impulse voltages were applied at the test gap. The electric field utilization factor ranges from 0.5 to 0.8. The experimental data of $SF_6$ and $N_2$ acquired in the same experimental condition are presented in parallel for comparison. As a result, the breakdown voltages in $SF_6$ and $N_2$ are linearly increased with the gas pressure, also the breakdown voltages in $N_2$ are increased with increasing the gap distance and electric field utilization factor. The positive breakdown voltages are higher than the negative breakdown voltages. The nagative basic lightning impulse withstand level of 150[kV] in $N_2$ of about 0.5[MPa] is nearly equal to that in $SF_6$ of 0.15[MPa]. It is seen from the results obtained in this work that $N_2$ can be used as an eco-friendly alternative gas to $SF_6$ in distribution power equipment.

뇌임펄스전압에 의한 불평등전계에서 토양방전특성 (Soil Discharge Characteristics in Inhomogeneous Field Caused by Lightning Impulse Voltages)

  • 유양우;김승민;김유하;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.95-101
    • /
    • 2015
  • This paper presents experimental results about characteristics of soil discharge as a function of moisture content when the $1.2/50{\mu}s$ lightning impulse voltage is applied. The laboratory experiments, for this study, were carried out based on factors affecting the transient behavior in soils. The electrical breakdown in soils was measured over a 0-6% range of moisture content for sands and a 0-4% range of moisture content for gravels. Needle-plane electrode systems was used As a result, the conduction current prior to ionization growth in dry soil is a little, but it in wet soil is increased with the applied voltage because the wet soil particles act as conductors. The soil impedance curves show an abrupt reduction just after breakdown. The general tendency measured in different soils is that the higher the water content, the lower the breakdown voltage and the shorter the time-lag to breakdown.

Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker

  • Gandhi, R.;Chandrasekar, S.;Nagarajan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1663-1672
    • /
    • 2018
  • In recent times, gas insulated medium voltage (MV) circuit breakers (CB) form a vital component in power system network, considering its advantages such as reduced size and safety margins. Gas insulation characteristics of circuit breakers are generally measured by lightning impulse (LI) test according to IEC standard 60060-1 as a factory routine test. Considering the environmental issues of $SF_6$ gas, many research works are being carried out towards the mixture of $SF_6$ gases for high voltage insulation applications. However, few reports are only available regarding the LI withstand and streamer propagation characteristics (at both positive and negative polarity of waveform) of $SF_6/N_2$ gas mixture insulated medium voltage circuit breakers. In this paper, positive and negative polarity LI tests are carried out on 22 kV medium voltage circuit breaker filled with $SF_6/N_2$ gas mixture at different gas pressures (1-5 bar) and at different gas mixture ratios. Important LI parameters such as breakdown voltage, streamer velocity, time to breakdown and acceleration voltage are evaluated with IEC standard LI ($1.2/50{\mu}s$) waveform. Weibull distribution analysis of LI breakdown voltage data is carried out and 50% probability breakdown voltage, scale parameter and shape parameter are evaluated. Results illustrate that the $25%SF_6+75%N_2$ gas filled insulation considerably enhances the LI withstand and breakdown strength of MV circuit breakers. LI breakdown voltage of circuit breaker under negative polarity shows higher value when compared with positive polarity. Results show that maintaining the gas pressure at 0.3 MPa (3 bar) with 10% $SF_6$ gas mixed with 90% $N_2$ will give optimum lighting impulse withstand performance of 22 kV MV circuit breaker.

불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성 (SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

절연유체 내 2상유동을 고려한 뇌임펄스 응답 유한요소해석 (Finite Element Analysis for Dielectric Liquid Discharge under Lightning Impulse Considering Two-Phase Flow)

  • 이호영;이종철;장용무;이세희
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2097-2102
    • /
    • 2011
  • Discharge analysis technique for dielectric liquid was presented by using the Finite Element Analysis (FEA) under a lightning impulse incorporating two-phase flow phenomena which described gas and liquid phases in discharge space. Until now, the response of step voltage has been extensively explored, but that of lightning impulse voltage was rarely viewed in the literature. We, therefore, developed an analyzing technique for dielectric liquid in a tip-sphere electrode stressed by a high electric field. To capture the bubble phase, the Heaviside function was introduced mathematically and the material functions for the ionization, dissociation, recombination, and attachment were defined in liquid and bubble, respectively. By using this numerical setup, the molecular dissociation and ionization mechanisms were tested under low and high electric fields resulted from the lightning impulse voltage of 1.2/50 ${\mu}s$. To verify our numerical results, the velocity of electric field wave was measured and compared to the previous experimental results which can be viewed in many papers. Those results had good agreement with each other.

불평등전계 중에서 $SF_{6}-N_{2}$ 혼합기체의 절연파괴 특성 (Breakdown Characteristics of $SF_{6}-N_{2}$ Mixtures in Nonuniform electric Field)

  • 이복희;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1999-2001
    • /
    • 2000
  • Impulse breakdown voltage characteristics of sulphur-hexafluoride/nitrogen ($SF_{6}-N_{2}$) mixtures were presented. The applied voltages were the positive and negative lightning impulse (1.2/44${\mu}s$) and oscillating impulse ($0.4{\mu}s$/2.08MHz) voltages. The predischarge current was observed to clarify the breakdown mechanism. The electrode system was consisted of plane to plane configuration with a needle-shaped protrusion whose length and diameter are 10mm and 1mm. The measurements were carried out at the gas pressure of mixtures up to 0.5MPa with nitrogen concentrations varying from 5 to 20%. The electrical breakdown in $SF_{6}-N_{2}$ mixtures develops with steplike pulses in leader mechanism. The minimum breakdown voltages for the negative lightning and oscillating impulse voltages were higher than those for the positive.

  • PDF

습한 토양의 임펄스방전특성 (Characteristics of Impulse Discharges in Wet Soil)

  • 김회구;이복희
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.363-369
    • /
    • 2017
  • This paper presents the experimental results related to soil ionization and electrical breakdown in a concentric hemispherical electrode system under lightning impulse voltages. Dynamic voltage-current and impedance-time characteristics of soil ionization were measured and analyzed. Also the electrical breakdowns of the soil gap were investigated. The time-lag to the peak current corresponds to the soil ionization propagation. The time of ionization propagation in wet sand is found to decrease with increasing the impulse currents. A drastic decrease in ground resistance was observed during the impulse current spreading in sand. The electrical breakdown appears at the wave tail of impulse voltage and results in a wide scatter in V-t curves. The voltage-current curves have a fan-like shape attributed to ionization processes which result in increasing current and decreasing voltage.

14주기 열화에 따른 22.9kV 전력케이블의 Lightning-Impulse 특성분석 (Lightning Impulse Characteristics for 22.9kV Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;허종철;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2274-2276
    • /
    • 2005
  • Cyclic aging for 14days is performed to remove the large amount of the volatiles found in freshly manufactured cable. In this paper, we examined lightning impulse characteristics of power cable before and after cyclic aging for 14days. As the result, the breakdown voltage after aging was lower than that before aging, but the breakdown voltage after aging was higher than that before aging in TR CNCV-W $60mm^2$ power cable.

  • PDF