• Title/Summary/Keyword: Lightning discharge

Search Result 90, Processing Time 0.032 seconds

Insulation Characteristics of Dry-air Insulated Switchgear for 72.5 kV Wind Power Generation (72.5 kV 풍력 발전용 Dry-air Switchgear의 절연 특성)

  • Chan-Hee Yang;Jin-Seok Oh;Hee-Tae Park;Young-il Kim
    • Journal of Wind Energy
    • /
    • v.15 no.2
    • /
    • pp.5-9
    • /
    • 2024
  • This paper describes the insulation breakdown characteristics of 72.5 kV dry-air insulated switchgear under development for installation in a wind power generator when a lightning impulse voltage is applied. For this study, the weak point of insulation due to the electric field concentration of the switchgear's internal shape was identified by finite element method (FEM) analysis, and the shape was actually simulated to measure and analyze the polarity of the lightning impulse voltage and the insulation breakdown characteristics according to the gas pressure at dry-air pressures of 0.1 Mpa to 0.45 Mpa. This study derives the maximum electric field with a 50 % discharge probability for each switchgear internal insulation vulnerable point based on the actual test and electrical simulation, which will be useful as reference data for supplementing and changing insulation design in the future.

An Automatic Measuring System of the Electric Fields Produced by Lightning Strokes (뇌방전에 의하여 발생하는 전장의 자동측정시스템)

  • Lee, Bok-Hee;Ahn, Chang-Hwan;Kil, Gyung-Suk
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.47-54
    • /
    • 1996
  • This paper deals with the electric field sensor and automatic measuring system of the time-varying space electric field produced by lightning discharges. The theoretical principle and the design rule of the measuring devices are investigated, and the semisphere-type electric field sensor and the signal process system are fabricated. From the calibration experiments, the frequency bandwidth of the measuring system ranges from 200 [Hz] to 1.56 [MHz] and the sensitivity is 0.96 [m V/V/m] as the amplification gain is 10. In addition, the electric field waveforms produced by lightning discharges are observed by the proposed electric field measuring system from June to August in 1995. The data is sampled with the time interval of 200 [ns] and is automatically recorded by transient signal analyzer(Necolet Pro 30), the resolution of which is 12 bit. And it is registered at personal computer. The electric field waveforms produced by intracloud discharge tend to be bipolar, with two or three narrow and fast rising pulses superimposed on the initial half-cycle.

  • PDF

Residual Voltage Reduction of Coaxial Surge Arrestor Using Ceramic Filler (세라믹 필터를 이용한 동축 서지어레스터의 잔류전압 저감)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.46-53
    • /
    • 2007
  • Extension of the mobile communication and the rapidly developing services connected with wireless multimedia(W-CDMA, DMB, Wibro, and so on) need great many base station transceiver systems, antennas, and many signal transmission line to embody these services. The min communication appliances system is exposed always in danger of transient overvoltage by direct stroke or induced lightning surge flowing in through antenna because the antenna of base station transceiver system or relay equipment is combined with expensive communication network equipments through signal transmission line. Now, gas discharge tube(GDT) or narrow band stub arrestor which is used by the surge protector for communication use is exposing limitations as for lightning surge protective means of the communication facility with high speed and wide frequency band. Therefore, for improving performance of surge arrestor, we applied ceramic filter which can reduce lightning surge invading from antenna effectively, and proved that ceramic filter is effective in residual voltage reduction through the experimental research.

Structure of Station Class Lightning Arresters and Electrical Characteristics of ZnO Varistor Blocks (발변전용 피뢰기의 구조 및 ZnO 바리스터 소자의 전기적 특성)

  • Cho, Han-Goo;Han, Se-Won;Lee, Un-Yong;Yoon, Han-Soo;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1158-1161
    • /
    • 2004
  • This paper presents structural characteristics of station class lightning arresters and electrical characteristics of manufactured ZnO varistor blocks which are usable in those arresters. Three types of station class lightning arresters were investigated and those are a ceramic arrester, a FRP tube type polymer arrester, and a FRP rod type polymer arrester. Each arrester has merits and demerits with structural characteristics. In general, polymer arresters were made of silicon rubber for housing materials, FRP tube or rod for mechanical strength, ZnO blocks for electrical characteristics, and metal parts for electrical contact and the silicon rubber, the housing materials, was directly injected to the arrester module which was assembly composed of electrodes, ZnO blocks and FRP tube or rod, and to prevent the nonlinear electric fields distribution on upper parts of arresters, the grade ring was adopted to the upper electrodes. The reference voltage, nonlinear coefficient, residual voltage, and voltage ratio of manufactured ZnO varistors are 4.90kV, 50, 9.54kV, 1.94, respectively. Compared to designed electrical characteristics, the reference voltage was low for 600v and the voltage ratio was slightly high. However, the characteristics of discharge withstand was so excellent that the mechanical destruction does not occur at the impulse current of $8/20{\mu}s$ 10kA for 100 times.

  • PDF

Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field (불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

A Study on the Microstructure and Electrical Characteristics of ZnO Varistor for d.c. Arrester (소결 조건 변화에 따른 직류 피뢰기용 ZnO 바리스터의 미세구조 및 전기적 성질에 관한 연구)

  • Kim, Seok-Sou;Choi, Ike-Sun;Park, Tae-Gon;Cho, I-Gon;Park, Choon-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.683-689
    • /
    • 2004
  • The microstructure and electrical characteristics of A ∼ C's ZnO varistors fabricated according to variable sintering condition, which sintering temperature was 1130 $^{\circ}C$ and speeds of pusher were A: 2 mm/min, B: 4 mm/min, C: 6 mm/min, respectively, were investigated. The experimental results obtained from this study were summarized as follows: The sintering density of A ∼C's ZnO varistors sintered at 1130 $^{\circ}C$ were decreased by sintering keep time to shorten, such as A: 9hour, B: 4.5hour and C: 3hour. A's ZnO varistor exhibited good densification nearly 98 % of theory density. In the microstructure, A∼C's ZnO varistors fabricated variable sintering condition was consisted of ZnO grain(ZnO), spinel phase(Z $n_{2.33}$S $b_{0.67}$ $O_4$), Bi-rich phasc(B $i_2$ $O_3$), wholly. Varistor voltage of A∼C's ZnO varistors sintered at 1130 $^{\circ}C$ increased in order A

A Study on Module Design and Performance of Polymer Arrester (폴리머 피뢰기의 모듈 설계 및 성능에 관한 연구)

  • Cho, Han-Goo;Chun, Jong-Uk;Kang, Yeong-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.108-111
    • /
    • 2003
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

Soil Ionization Phenomena around a Hemispherical Electrode Stressed by Impulse Voltages (임펄스전압에 의한 반구형 전극계에서 토양의 이온화 현상)

  • Heo, Dae-min;Kim, Hoe-gu;Lee, Bok-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.601-608
    • /
    • 2016
  • The electrical characteristics of the soil where a ground electrode is buried vary with regions, seasons and environmental factors. Electrical discharge in the vicinity of the ground electrode will occur differently and significantly affect the performance of the grounding system. It is necessary to analyze discharge and ionization characteristics of soils when the grounding system is designed. The aims of this investigation are to understand correlation between the soil ionization and the transient ground impedance. This paper presents the experimental results on the soil ionization parameters and the transient ground resistance due to the soil ionization around a hemispherical ground electrode stressed by lightning impulse voltages.

A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coils (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.250-253
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for commnuication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the activation voltage required to initiate the discharge process in the GDTs for sufficient amount of time can be large enough to damage surge-sensitive protected circuits. For GDTs with a considerably high initial over-voltage value, we should limit the peak voltage using a TVS or filter. As for ZnO varistors, even though their performance for voltage restriction is excellent, their applications in high-frequency commnuication circuits have been limited because of higher internal capacitance when compared to the GDTs. In order to develop a surge protector for commnuication applications by taking advantages of these two devices, we built a combination circuit that connects a GDT and a ZnO varistor along with a choke coil in common and differential modes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurements at each step. The experiment results show that the surge voltage restriction with the choke coil is more effective in 100 [kHz] RingWave voltage than in lightning impulse voltage.

  • PDF

A Study on the Optimal Selection of Lightning Arresters for DC Electric Traction Vehicles (직류전동차 탑재용 피뢰기의 최적선정에 관한 연구)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Song, Jae-Yong;Kim, Il-Kwon;Park, Dae-Won;Han, Moon-Sup
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.112-116
    • /
    • 2007
  • In this paper, we proposed a selection and application recommendations of ZnO arresters for DC electric traction vehicles. To decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_r$), and the Nominal Discharge Current(In), we measured and analyzed system voltages and surge currents flowing the arrester installed on a DC electric traction vehicle under running state. System voltages measured up to 1,800 V in 1,500 V-system, and surge currents were recorded up to 3 times per a running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and a standard EN50163, we could proposed $U_C$, $U_r$, and In available for the 1,500 VDC electric traction vehicles.