• 제목/요약/키워드: Lightning Surge

검색결과 292건 처리시간 0.023초

봉상접지극의 임펼스 전류에 대한 과도접지임피던스 특성 (Characteristics of Transient Grounding Impedances of Rod Electrodes)

  • 이복희;박종순;양정재;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1645-1647
    • /
    • 1997
  • Electronic circuits are becoming more vulnerable owing to the development of integrated circuit. Computer and info-communication facilities are very sensitive to surges caused by lightning, and they can suffer a malfunction and damage. Recent concern about damage and upset caused by transient overvoltages has focused on surge protection. The most important parameter in surge protection is the transient grounding impedance. In this paper, the transient grounding impedances of a rod electrode have been measured under impulse current waves. Z-t, Z-i and V-i characteristics of the grounding electrode in according to the length of the grounding lead wire were obtained and analyzed.

  • PDF

뇌서지 유입 시 새로운 스파크-갭을 활용한 전원회로 보호 대책 (A Solution to Protect the Power Supply Circuit Employing a New Spark-gap during Lightning Surge Inflow)

  • 이강희;박준우;류동균;원재선;홍성수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.153-154
    • /
    • 2013
  • 고전압, 대전류를 갖는 뇌서지는 전원회로에 유입되었을 때 소자 파손 및 회로 오동작 등의 문제를 일으킨다. 이에 대한 보호대책으로 SPD(Surge Protection Device)소자와 스파크-갭(Spark-gap)을 주로 사용한다. 이 때, 기존의 스파크-갭은 뇌서지 유입 시 방전현상 이후에 발생된 스파크-갭의 패턴 마모로 패턴의 복구가 불가능하고, 불규칙하고 변칙적인 방전으로 인하여 발생되는 서지주요 예측경로의 소자 및 패턴 파괴와 같이 2차적인 문제를 발생시킨다. 이를 해결하기 위해 본 논문에서는 초기 유입 시부터 스파크-갭의 방전을 통해 에너지를 우회시킴으로서 전원회로의 뇌서지 부담을 줄여 전원회로의 안전성 및 안정적인 정상동작을 확보하는 대책을 제안하고, 스파크-갭의 구조에 따른 효과를 실험을 통해 검증한다.

  • PDF

22.9 kV 배전용 계폐기의 개폐서지 측정시스템 구성에 관한 연구 (A Study on the Measuring System of the Switching Surges in the 22.9 kV Distribution Lines)

  • 박상만;윤태상;노황래;한용희;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3094-3096
    • /
    • 2000
  • In the distribution systems, there are generally two sources of transient over-voltages. One is the capacitor switching surge and the other is the lightning surge. This paper is written about the measuring and analysis of switching over-voltages in the 22.9 kV multi-grounded distribution systems. The measurement was performed in the Kochang distribution test line in January, 2000.

  • PDF

345kV급 GIL이 연계된 혼합송전선로의 뇌서지해석 및 평가 (Transient Analysis and Evaluation of 345kV Combined Transmission Line Connected with GIL)

  • 장화윤;이종범;김용갑;정채균
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1949-1955
    • /
    • 2010
  • This paper describes the characteristic and effectiveness of combined GIL transmission line through lightning surge analysis. In addition the XLPE cable is analyzed in the same condition to compare with GIL. Lighting surge analysis is carried out by EMTP/ATP-Draw to obtain overvoltage of GIL and XLPE cable at service-point and load-out area of underground line. Propagation velocity is calculated in combined transmission lines with GIL and XLPE cable. The overvoltage is also analyzed on GIL and XLPE cable with or without arrester operation. The Analysis results show that overvoltage of GIL is occurred higher than XLPE cable at the same condition. Therefore it is evaluated that the application of GIL at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

신호.통신회로용 과도전압 차단장치 개발에 관한 연구 (A Study on the Development of a Transient Voltage Stocking Device for Signal and Telecommunication Lines)

  • 송재용;이종혁;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 추계종합학술대회
    • /
    • pp.490-493
    • /
    • 1999
  • Due to the miniaturization of electrical components and assembles on signal and telecommunication circuits, transient overvoltages caused by switching operation or lightning surge has become more interesting concern to the field of electrical engineering. This paper describes the development of transient voltage blocking devices (TBDs) that can protect sensitive signal and telecommunication devices from overvoltages. Two kinds of TBDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}$s 2.1kA according to the IEC 1000-4-5 standard. From the simulation and experimental reults, it is confirmed that the proposed TBD has an enough protection performance in low insertion loss and tight clamping voltage.

  • PDF

TVS 다이오드의 전기적 특성 및 과도 열방출 특성 해석 (The Electrical and Transient Thermal characteristics of TVS diode for Surge Absorber)

  • 김상철;김형우;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.208-212
    • /
    • 2003
  • Silicon transient voltage suppressors (TVSs) are clamping devices that limit voltage spikes by low impedance avalanche breakdown of a rugged silicon PN junction. They are used to protect sensitive components from electrical overstress such as that caused by induces lightning, inductive load switching and electrostatic discharge. In this paper, we present static and dynamic characteristics of TVS diode using thermal analysis simulation software. And also, it is presented that the thermal dissipation characteristics of TVS diode in the transient state.

  • PDF

전원선용 SPD의 효과적인 설치기법 (An Effective Approach of Installation of Surge Protective Devices for AC Mains)

  • 이동문;정동철;이승칠;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2229-2231
    • /
    • 2005
  • Recently, damages of electronic equipments due to lightning surges coming from AC power lines are increasing. In this work, to propose the effective installation methods of surge protective devices(SPDs), the protective performances of SPDs in actual-sized test circuits were experimentally investigated. In order to obtain the lowest limiting voltage and best protection, long leads of SPDs in installation practices are significantly undesirable. An effective installation method of SPDs for AC mains was proposed. The way of installing SPDs at every branch circuits is more effective than that of installing a SPD near the point of entry.

  • PDF

대형 봉상 접지전극의 접지임피던스와 주파수 응답특성 (Ground Impedance and Frequency Response Characteristics of Large-scale Ground Rods)

  • 이복희;엄주홍;김태두;정동철;길형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1791-1793
    • /
    • 2003
  • In order to analyze the dynamic characteristics of ground impedance in large grounding system for lightning and surge protections, a novel method for measuring the ground impedance as a function of frequency was proposed. The experiments were carried out in the grounding system composed of ground rods and mesh grids. The test current was injected by the variable frequency inverter whose frequency is linearly controlled in the range of $5{\sim}500$kHz. The ground impedance and frequency response of the grounding system were mainly caused by the inductive current flowing through grounding conductors over the frequency of 2002. In the combined grounding system of rods and mesh grids, inductive component of ground impedance was significantly decreased. It was fumed out that the grounding system is effective for the surge protection.

  • PDF

서지전류가 입사된 ZnO 바리스터에 흐르는 누설전류의 특성 (Characteristics of leakage currents flowing through ZnO varistor exposed to surge currents)

  • 이복희;이봉;이수봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.338-341
    • /
    • 2006
  • This paper presents the leakage current characteristics of ZnO varistors exposed to the $8/20{\mu}s$ lightning impulse currents as functions of the number of injection and amplitude of impulse currents. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of $5[kA_p]$ was used. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents were measured under 60 Hz AC voltages. The trend curves of resistive leakage current of ZnO varistors were analytically calculated.

  • PDF

뇌서지에 의한 플라이백 컨버터의 서지전류 경로 분석 (Analysis of Surge Current Path of Flyback Converter by Lightning Surge)

  • 박준우;이강희;김진호;홍성수;원재선;김종해
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.385-386
    • /
    • 2012
  • 기존 뇌서지에 관한 논문은 정보통신 설비 및 전력계통의 대책에 관한 연구가 진행되어 왔으나, SMPS에 관한 연구는 부진하였다. 따라서, 본 논문에서는 조합파 신호발생기를 통하여 서지전압 인가에 따른 플라이백 컨버터에서의 서지전류 경로를 분석한다. 또한, 새로이 발견한 서지전류로 인하여 발생되는 주요 소자파손 원리를 제시한다. 최종적으로 서지경로 상의 실제 측정 결과를 제시하여 제안 방식의 타당성 및 유효성을 검증하였다.

  • PDF