• 제목/요약/키워드: Lightning Surge

검색결과 291건 처리시간 0.024초

애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발 (Development of a Ubiquitous Sensor for Monitoring Insulators and Arresters)

  • 길경석;신광철;박종국;심재원;송재용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.736-741
    • /
    • 2006
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold(S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 500A to 10kA with $8/20{\mu}s$-waveform.

  • PDF

전기철도용 피뢰기 선정에 관한 연구 (A Study on the Selection of Lightning Arrester for DC Electric Traction Vehicles)

  • 길경석;송재용;김일권;문승보;한주섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.581-586
    • /
    • 2006
  • Selection and application recommendations of lightning arresters for DC electric traction vehicles are presented. To decide arrester specification such as continuous operating voltage(COV, $U_c$), rated voltage($U_R$), and nominal discharge current($I_n$), variations of system voltage and surge currents flowing arresters were analyzed in running-service of traction vehicles. System voltages increased up to 1,800V during anti-breaking. Surge currents recorded 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From the field measurement and consideration of EN50163, COV, $U_c$, and $U_R$ for the $1,500V_{DC}$ traction vehicles were proposed.

  • PDF

지중송전 및 배전계통에서 알루미늄 도체 선로운용의 실용성 평가 (Evaluation of Operation Practicality on Line with Aluminum Conductor in Underground T&D Systems)

  • 장주영;이종범;김용갑
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.492-499
    • /
    • 2011
  • This paper describes that the evaluation on operation practicality of Al conductor cable will be used instead of Cu conductor cable. Analysis is divided into two kinds of cases as transmission and distribution. To evaluate that Al conductor line has the insulation strength indeed safely, various analysis and calculation such as single line-to-ground fault current, lightning surge and allowance current were carried. Model was established based on real combined transmission and distribution is being used in utility with EMTP. The analysis results on Al and Cu conductor line were compared each other. It was proved that Al conductor line can be operated instead of Cu conductor line without special insulation problem in transmission and distribution, in electrical view point such as overvoltage and allowance current.

PoE(Power Over Ethernet)에서 임펄스성 서지보호 이중화 장치 설계 (Design on a Dual Impulse Surge Protector for the Power over Ethernet Devices)

  • 진종호;김영진;이영철
    • 한국전자통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.927-934
    • /
    • 2015
  • 본 논문에서는 산업현장에서 자연현상에 의하여 발생하는 임펄스성 서지(surge)에 의한 PoE(Power Over Ethernet)시스템의 통신 장애를 예방하기 위하여 이중화된 임펄스성 서지 보호회로를 설계하여 PoE 통신설비의 임펄스성 서지의 대책 방안을 제안하였다. PoE에 따른 임펄스성 서지신호의 특성을 분석하기 위하여 국제표준 IEC 61000-4-5에 적합한 서지 발생장치를 개발하였으며 서지 발생장치를 PoE 데이터 전송 라인에 인가하여 설계 제작한 이중화된 PoE 전원공급 보호회로에 의하여 순차적으로 임펄스성 서지 신호가 약화됨을 확인하였다.

가입자 통신 선로에서의 뇌격 파라미터 분석과 측정 (Analysis and Measurement of Lightning Parameters on Subscriber Telecommunication Lines)

  • 오호석;박동철
    • 한국전자파학회논문지
    • /
    • 제18권11호
    • /
    • pp.1309-1317
    • /
    • 2007
  • 본 논문은 낙뢰에 의해 전송 선로에 유기되는 유도뢰 전압을 해석하고 낙뢰 위치 및 선로 길이에 따른 유도뢰 전압의 크기, 파두장, 파미장 등에 대한 낙뢰 파라미터 변화를 분석하였다. 분석한 결과를 확인하기 위해 실제 통신 선로를 대상으로 유도뢰 전압을 측정하였다. 선로 길이가 길어짐에 따라 그리고 낙뢰 위치가 선로와 멀어짐에 따라 파두장, 파미장이 증가하는 경향을 확인하였다. 전체 선로 길이보다는 가공 선로 길이가 상대적으로 유도 전압 크기에 영향을 끼침을 확인하였다.

보호거리에 따른 전압제한형 SPD의 보호효과에 대한 시뮬레이션기법 (Simulation Method on the Protection Effects of Voltage-Limiting Type SPDs Associated with the Protective Distance)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a method of simulating the protection effects of surge protective devices(SPDs) depending on the protective distance and types of input impedance of load to be protected. In order to analyze the protective performances of voltage-limiting type SPDs associated with the reflection and oscillation phenomena, the terminal voltage across load being protected and the residual voltage of SPDs were simulated by using EMTP model as functions of the protective distance and types of input impedance of loads. As a consequence, SPDs should be installed by taking into account the protective distance and input impedance of loads to achieve reliable protection of electrical and electronic equipment from lightning and switching surges. It is expected that the simulation method proposed in this paper could be practically used in design for installing SPDs in low-voltage distribution systems.

보호거리와 부하 유형에 따른 SPD의 보호효과에 대한 실험적 고찰 (Experimental Examinations on Protective Effects of SPDs Associated with the Protective Distance and Type of Load)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.81-88
    • /
    • 2012
  • Surge protective devices(SPDs) are widely used as a most effective means protecting the electrical and electronic equipment against overvoltages such as lightning and switching surges. When installing SPDs, it is essential that the voltage protection level provided by SPDs should be lower than the withstand voltage of the equipment being protected. But even the proper selection of SPDs are achieved, the voltage at the equipment terminal may be higher than the residual voltage of SPD due to the reflection and oscillation phenomena. This paper was focused on the investigations of the conditions for which the equipment is protected by an SPD taking into account the influences of the protective distance and type of load. The protective effects of SPD with voltage-limiting component were analyzed as functions of types of load and protective distance between the SPD and load. As a result, in the cases of long protective distances, capacitive loads and loads with high resistance, the voltage at the load terminal was significantly higher than the residual voltage of SPD. It was found that the proper installation of SPDs should be carried out by taking into account the protective distance and type of load to achieve reliable protection of electronic equipments against surges.

저압용 SPD가 설치된 전력선통신에서 데이터전송 성능 향상 (A Method for Enhancing Data Transmission Performance in the Power-Line Communication Channel with Low-Voltage Surge Protective Devices)

  • 최종민;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.78-85
    • /
    • 2012
  • Low-Voltage power lines should equip surge protection devices which protect electronic equipments and human lives against lightning and abnormal voltages. Data transmission capacity of the power line is determined by frequency characteristics of the surge protective devices. To analyze the effects of surge protective devices on the data transmission performance, various combinations of installation methods are tested which include ZnO varistor elements that is compatible with class I, class II and class III. The result claims that ZnO varistor for class III is found to be one of the main factors that deteriorates the transmission performance. To overcome this problem a serial connection methed between Gap type SPD and ZnO varistor is proposed. With the proposed scheme, laboratory experimental results show that the data transmission performance can be improved up to 91.9[%] with proper SPD combination.

Arrester용 digital surge counter의 서지 검출 장치에 관한 연구 (The study on surge detector of digital surge counter for arrester)

  • 김석수;최익순;조동환;이강섭;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.170-174
    • /
    • 2005
  • The purpose of this study is to design the digital surge counter for lightning arresters. The used detecting method for surges is using the signal of both ends of ZnO varistor. The electronic detecting parts of the digital counter are arranged in outside of main processer for protecting it from noise. The detecting parts change detected signals into small signals. The countermeasures for noises are (1) Shielding (2) Reinforcement of power circuits (3) Cables & Circ1e core (4) Watch-doc & control of input signals.

  • PDF

다상 가공선로의 유도뢰 전압 해석을 위한 프로그램 개발 (Development of Computer Program for Calculation of Induced Lightning Voltages on Overhead Multiconductor Systems)

  • 이용한;박동욱;임용혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.418-421
    • /
    • 1989
  • A program for numerical analysis of induced lightning surge is developed. The program first converts simultaneous differential equations into simultaneous difference equations for line sections without transition points, and calculates the line voltage and current by solving a determinant. It, then, calculates the line voltage and current at transition points by applying kirhhoffs law. This program is potentially useful in a wide range of applications for investigating the effect on distribution lines of lightning protection equipment such as lightning arresters and overhead ground wires.

  • PDF