• Title/Summary/Keyword: Lightning Impulse Voltage

Search Result 153, Processing Time 0.035 seconds

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

A Study on the Electromagnetic Transients in A Power System (전력계통의 전자과도현상에 관한 연구)

  • 김경철;강창원;이일무
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

Energy Coordination between Cascaded Voltage Limiting Type SPDs in Surge Currents due to Direct Lightning Flashes (종속 접속된 전압제한형 SPD의 직격뢰 서지전류에 대한 에너지협조)

  • Lee, Bok-Hee;Um, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.68-75
    • /
    • 2014
  • Cascaded applications of surge protective devices(SPDs) are required in order to reduce the stress on the electrical and electronics equipment being protected, and the energy coordination between the cascaded SPDs is very important. This paper deals with the experimental results obtained from the installation conditions of full-scale SPDs. The energy coordination between the upstream Class I SPD and the downstream Class II SPD was measured using a $10/350{\mu}s$ impulse current due to direct lightning flashes. The distances between the cascaded SPDs were 3, 10, and 50m, and the maximum test current was 12.5kA. As a result, the energy sharing between cascaded SPDs was dependent on the voltage protection level of each SPD and the distance between two SPDs. An overview of how to select SPD ratings in applications of cascaded SPDs system was discussed based on the energy coordination between the two SPDs. The proposed test results for the energy coordination between two-stage cascaded SPDs can be used in effective applications of SPDs.

Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell (포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발)

  • Hong, J.Y.;Lee, J.B.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

Lightning Impulse Breakdown Voltage Characteristics for 22.9kV TR CNCV-W Power Cable Before and After Cyclic Aging for 14days (14주기 열화에 따른 22.9kV TR CNCV-W 전력케이블의 Lightning-Impulse 파괴전압 특성분석)

  • Kim, We-Young;Heo, Jong-Cheoi;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1505-1506
    • /
    • 2006
  • XLPE 절연 전력케이블의 제조과정에서 발생하는 가교부산물을 제거할 목적으로 14주기노화를 실시한다. 이 과정에서 가교부산물이 제거되는 효과도 있지만 열에 의한 구조적 결함도 생기게 되며, 이들 모두가 뇌충격파괴전압에 영향을 준다. 22.9kV 트리억제형(TR CNCV-W) 케이블에 대하여 14주기노화 전과 후의 파괴전압을 분석하였으며, 전반적으로 노화과정이 파괴전압을 감소시키는 결과를 보였으나 60 $mm^2$ 케이블은 상승효과와 감소효과가 비슷하게 작용하는 것으로 나타났다.

  • PDF

Inter-comparison Test of Lightning Impulse High Voltage Reference Measuring System (뇌충격 고전압 기준측정시스템의 국제비교시험)

  • Kim, Min-Kyu;Lee, Jeong-Gi;Choi, Ik-Soon;Jeong, Ju-Young;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2217-2219
    • /
    • 2005
  • In this paper, an inter-comparison test of lightning impulse reference measurement system between Korea and Japan is reported. At present, such a direct comparison test as the activity to sustain the traceability of the measurement system is generally proposed. Due to the inter-comparison test, ascertaining the grade of the measurement uncertainty and maintaining the level of reference system are accomplished.

  • PDF

The Installation Technique of Grounding Electrode Conductors for Metal Oxide Distribution Surge Arresters (배전용 피뢰기의 접지도선 설치기법)

  • Lee, B.H.;You, I.S.;Lee, T.R.;Ahn, C.H.;Youn, J.S.;Youn, H.H.;Kim, J.S.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1718-1720
    • /
    • 2001
  • The route of surge arrester connection is very important because bends and kinds of leads increase the impedance to lightning surges and tend to nullify the effectiveness of a grounding electrode conductor. There is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and bonding for 18[kV] metal oxide distribution line arresters was experimentally investigated with lightning and oscillating impulse voltages.

  • PDF

A Type Test of 154 kV Transmission Line Arrester for improvement of lightning performance (내뢰성 향상을 위한 154 kV 송전선용 피뢰기의 성능 시험)

  • Kwak, J.S.;Kang, Y.W.;Woo, J.W.;Shim, E.B.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.454-456
    • /
    • 2003
  • This paper describes a type test results of 154 kV transmission line arrester with external gap. The test was carried on surge arrester unit and line arrester with external gap, respectively. Withstand voltage test demonstrate the voltage withstand capability of the line arrester with external series gap under the dry and wet conditions. In insulation coordination test external series gap shall be discharged every time when lightning impulse voltage with the steepness of more than 1500 $kV/{\mu}s$ are applied under the wet condition.

  • PDF

Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field (준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성)

  • Lee, Bok-Hee;Kim, Dong-Kyu;Li, Feng
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.126-132
    • /
    • 2010
  • This paper presents dielectric characteristics of $N_2$ gas under impulse voltages in a quasi-uniform electric field gap. The experiments were carried out at the test gap applied by the 1.2/50[${\mu}s$] lightning impulse voltage, 180/2500[${\mu}s$] switching impulse voltage, 500[ns]/1[MHz] very fast transient overvoltage(VFTO). The gap separation of sphere-to-plane electrodes was 14[mm] and the electric field utilization factor was about 71.2[%]. The gas pressure ranges from 0.2 to 0.6[MPa]. As a result, the electrical breakdowns are occurred by streamer discharge. Breakdown voltages are linearly increased with the gas pressure and the highest breakdown voltage is appeared under the VFTOs having fast rising time. Breakdown voltages under the positive impulse voltages were higher than those under the negative ones, and also the time to breakdown in the positive polarity is longer than that in the negative polarity.

Comparative Performance Evaluation of Lightning Air Terminals by the HV Laboratory Test (고전압 모의시험을 통한 피뢰침의 성능 비교평가)

  • Lee, Jae-Bok;Myeong, Seong-Ho;Jo, Yeon-Gyu;Kim, Jeom-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.627-632
    • /
    • 2001
  • There are claims that ESE(Early streamer emission) Air terminals offer a vastly increased zone of protection over that of traditional lightning rods by causing the emission of an upward streamer/leader that will propagate towards the tip of downward leader at an early stage in the attachment process than would occur for a simple rod in the same geometrical configurations. This paper shows the results of comparing test a particular type of ESE air terminals with a simple rod conducted in the KEH HV laboratory, which are lightning impulse voltage test, flashover direction test and corona emission current measurement. The results from this test show a completely random scattering of flashovers to the conventional and ESE air terminals under identical electrics] and geometrical conditions, and thus shows no advantage of one terminal over the other.

  • PDF