• Title/Summary/Keyword: Lightning Current

Search Result 313, Processing Time 0.023 seconds

Frequency Dependent Grounding Impedance As a Function of Soil Resistivity (대지저항률에 따른 접지임피던스의 주파수 의존성)

  • Bae, Sung-Bae;Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • A design criterion of grounding systems is commonly based on low frequency resistance in Korea. When lightning surges which have high frequency components are injected into the grounding system, the grounding impedance is greatly different from the static grounding resistance. This paper presents the grounding adimittance and phase on the frequency range from 100 [Hz] to 15 [MHz] using water tank simulating the grounding system in different water resistivities. As a result, capacitive effect is dominant over the frequency of 100 [kHz] at the water resistivity of 1,000 [$\Omega$ m]. On the other hand, the inductive characteristics appear at the low water resistivity. Consequently, dependence of grounding impedances on the frequency of injected current is strongly related to resistivity.

  • PDF

Development of a Surge Protective Device for Signal Lines on Shipboard (선박 신호회로용 서지방호장치의 개발)

  • Seo, Hwang-Dong;Song, Jae-Yong;Han, Ju-Seop;Kim, Yoon-Sik;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1161-1165
    • /
    • 2005
  • Due to the miniaturization of electrical components and assembles on signal circuits, transient overvoltages caused by switching operation or lightning surges have become more interesting concern to the field of electrical engineering. In this paper, the development of surge protective devices(SPDs) that can protect sensitive signal device on shipboard from overvoltages are described. Two kinds of SPDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}s$ 2.1kA according to the IEC 61000-4-5 standard. From the simulation and experimental results, it is confirmed that the proposed SPDs have an enough protection performance with a low insertion loss and a low clamping voltage.

  • PDF

Characteristics of Transient Grounding Impedances of Rod Electrodes (봉상접지극의 임펼스 전류에 대한 과도접지임피던스 특성)

  • Lee, B.H.;Park, J.S.;Yang, J.J.;Lee, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1645-1647
    • /
    • 1997
  • Electronic circuits are becoming more vulnerable owing to the development of integrated circuit. Computer and info-communication facilities are very sensitive to surges caused by lightning, and they can suffer a malfunction and damage. Recent concern about damage and upset caused by transient overvoltages has focused on surge protection. The most important parameter in surge protection is the transient grounding impedance. In this paper, the transient grounding impedances of a rod electrode have been measured under impulse current waves. Z-t, Z-i and V-i characteristics of the grounding electrode in according to the length of the grounding lead wire were obtained and analyzed.

  • PDF

Thermal Stability Evaluation of SPDs with Parallel or Series Circuit Assemblies (SPD 직병렬 조합회로의 열적 안정성 평가)

  • Eom, Ju-Hong;Cho, Sung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.265-269
    • /
    • 2005
  • Surge protective devices can be divided into three categories based on the circuit assembly: a parallel circuit type that considers the surge current amount within the device, a series circuit type that considers the voltage and single circuit type that uses a single element. However, when assembling SPDs, there are many things including function and safety to be taken into consideration because they are directly related to the performance and safety of the device. In this paper, we executed an experimental comparative study of performance and thermal stability of each SPD type using lightning surge generator and thermal image camera.

  • PDF

Analysis of Ground Impedance of a Ground Rod Using Circuit Models (회로모델을 이용한 봉상전극 접지임피던스의 분석)

  • Lee, Bok-Hee;Lee, Tae-Hyung;Eom, Ju-Hong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.95-99
    • /
    • 2004
  • A systematic approach of measurement, modeling and analysis of grounding system impedance in the field of lightning protection systems is presented. The measurement and analysis of ground impedance are based on a computer aided technique. The magnitude and phase of ground impedance were measured and analyzed by the modified fall-of-potential method and the proposed computer program algerian using the waveforms of the test current and potential rise. The theoretical analysis of ground impedance were performed with the equivalent circuit models, and the theoretical results were compared with the measured data.

  • PDF

Electrical Characteristics Test of Distribution Polymer Lightening Arresters (배전용 폴리머 피뢰기의 전기적 특성시험)

  • Kwon, Tae-Ho;Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Yoon, Tae-Sang;Jung, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.546-549
    • /
    • 2004
  • This paper describes the electrical characteristics of the polymer lightning arresters(L.As) used to protect distribution lines and power facilities from surge. For the relative comparison, the characteristics assessment was done for 2 states of L.As before and after water immersion treatment. The L.As for the comparative test were immersed with water of $95[^{\circ}C]$ considered a severe condition. After the immersion treatment, the assessment was carried out for material analyses in chemical structure(FTIR : fourier transform infrared spectrophotometer). Electrical performance measured insulation resistance measurement, leakage current measurement, critical operation voltage measurement etc.. In addition to, the results were compared with those for the L.As deteriorated in the field. Thus, the accelerative deterioration degree of polymer materials by immersion treatment was evaluated, by which the structural defects of the polymer L.As could be inferred.

  • PDF

A Study on the Development of a Transient Voltage Stocking Device for Signal and Telecommunication Lines (신호.통신회로용 과도전압 차단장치 개발에 관한 연구)

  • 송재용;이종혁;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.490-493
    • /
    • 1999
  • Due to the miniaturization of electrical components and assembles on signal and telecommunication circuits, transient overvoltages caused by switching operation or lightning surge has become more interesting concern to the field of electrical engineering. This paper describes the development of transient voltage blocking devices (TBDs) that can protect sensitive signal and telecommunication devices from overvoltages. Two kinds of TBDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}$s 2.1kA according to the IEC 1000-4-5 standard. From the simulation and experimental reults, it is confirmed that the proposed TBD has an enough protection performance in low insertion loss and tight clamping voltage.

  • PDF

Prebreakdown Corona Processes of Point-to-Plane Gap in $SF_{6}$ Gas ($SF_{6}$ 가스중에서 침-평판가극의 전구코로나과정)

  • 이복희;백용현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.140-143
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_{6}$ gas and prebreakdown growth caused by lightning impulse voltages in inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is obserbed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrustion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields ad partial discharges in voids.

  • PDF

Two-Stage Surge Protection Device with Varistor and LC Filter. (바리스터와 LC필터를 사용한 2단 서지보호장치)

  • Lee, B.H.;Kim, J.H.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

Transient Ground Impedance of Small-sized Ground Electrode considering Underground Discharge in Frozen Soil (동결 토양에서 지중방전을 고려한 소규모 전극의 과도접지임피던스 특성)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.324-327
    • /
    • 2009
  • This paper presents the transient impedance in a discharge region when high voltage lightning impulse is applied to small-sized ground electrodes in frozen soil. For a realistic analysis of ionization characteristics near the ground electrode in the soil, ground rod installed outdoors and high voltage impulse voltage generator were used. From the analysis of response voltage and current flowing ground electrode to earth, it was verified that the ionization near the ground electrode contributes to reduction of ground impedance and limits the ground potential rise effectively under high impulse voltage.

  • PDF