• 제목/요약/키워드: Lighting and Cooling Energy

검색결과 89건 처리시간 0.026초

LED 조명용 히트싱크 방열기 설계를 위한 냉각성능 평가 (Evaluation on the Cooling Performance to Design Heat sinks for LED lightings)

  • 정태성;강환국
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.778-784
    • /
    • 2012
  • In comparison with some other light sources, LED has merits such as increased life expectancy, fast response, pollution free, and high energy efficiency. Lately, due to development of LED with high brightness and capacity, LED has widely used in many industrial fields such as automotive, aviation, display, transportation and special lighting applications. Since the high heat generation of LED chips can cause a reduction in lifetime, degradation of luminous efficiency, and variation of color temperature, studies have been carried out on the optimization of LED packaging and heat sinks. In this study, experiments on measuring the heat generation rate of LED and the cooling performance of a heat sink were carried for analyzing the thermal characteristics of LED lighting system in free convection. From the results, dimensionless correlation on the cooling performance of heat sink in natural convection was proposed with Nusselt number and Rayleigh number as a guideline for designing cooling device of LED lightings.

TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석 (Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

비냉각형 고효율 태양광 채광시스템 및 응용에 관한 연구 (Un-Cooled High Efficient Solar Lighting System and its Application)

  • 이호열;김명진;신서용
    • 한국통신학회논문지
    • /
    • 제36권11B호
    • /
    • pp.1394-1402
    • /
    • 2011
  • 본 논문은 포물 반사경 방식 및 프레넬 렌즈 방식을 이용한 태양광 집광장치 및 이의 응용에 관한 것이다. 본 시스템은 대구경 반사경과 더불어 2차 광학계를 도입하여 광섬유로 입사되는 빛의 입사각을 광섬유의 개구수보다 작게 함으로써 집광효율을 극대화하였다. 또한 광섬유 단면에 입사하는 빛의 에너지 밀도를 낮게 하기 위해 광섬유 다발 직경 크기와 동일한 평행광이 광섬유로 입사되게 함으로써 반사경을 사용한 집광 시 문제가 되는 열발생 문제를 별도의 냉각장치 없이 근원적으로 차단하였다. 최근 각광받고 있는 식물공장에 주로 쓰이는 LED와 같은 인공광원 대신 본 연구에서 개발한 태양광 집광장치를 식물공장에 적용하여 인공조명과 태양광의 혼합조명장치를 통해 식물을 재배하였다. 그 결과 낮 시간대에 인공조명에 소요되는 전기에너지를 대폭 절감할 수 있었다. 혼합조명장치에서는 조도센서를 활용하여 항상 일정량의 빛이 식물에 제공되도록 LED등의 밝기를 조절하였다. 하루 10시간 기준으로 100형 규모의 식물공장에 태양광 채광시스템을 적용할 경우 한 달에 약 28,080KWh의 에너지 절감효과가 있다.

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

롤링을 통한 창호부착형 에어캡 모듈 개발 (Development of the Aircap Module Attached to the Window Through Rolling)

  • 허지운;서장후;김용성;이행우
    • 설비공학논문집
    • /
    • 제29권11호
    • /
    • pp.559-569
    • /
    • 2017
  • Various studies examining how to conserve building energy have been conducted recently. From such studies it has been determined that insulation performance of an aircap is viable and therefore aircaps are used as material for improving insulation performance of windows. However, the aircap for improving insulation performance of a window is attached on the front, causing infringement of the prospect right. Therefore, the purpose of this study is to develop an aircap module attached to the window through rolling, conducting performance verification throughfull-scale testbed and verifying its effectiveness. Findings of this study are as follow : 1) The module suggested in this study enables setting of an area wherein the aircap is attached through rolling so that the aircap rolls up using Velcro tape, and an insulation bar is suggested to block the gap between the aircap and window glass. 2) When the aircap is applied to the window, consumption of lighting energy increased during summer and winter by 2.8%~16.4% and 0%~76.2% respectively in comparison to no aircap application, indicating that it is unsuitable for conserving lighting energy. 3) In terms of conserving cooling and heating energy, an advantageous or effective aircap attachment method is the method whereby an aircap is attached to the front surface of a window. However, the method whereby an aircap is attached to a part of a window and where no aircap is attached increases consumption of cooling and heating energy during summer and winter by 6.0%~35.7% and 2.7%~41.6% respectively in comparison to the method wherein an aircap is attached to the front surface of a window. 4) In consideration of conserving cooling, heating and lighting energy, the attachment of an aircap to the front surface of window is the most appropriate method, and it is appropriate to attach the aircap at a position that is 1,500 mm or higher from the floor to secure the prospect right and minimize energy loss.

시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가 (The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program)

  • 정열화;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례 (A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit)

  • 권경우;이석주;박준석
    • 설비공학논문집
    • /
    • 제26권8호
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

생태적 개념을 도입한 초등학교 실내공간 디자인에 관한 연구 (A Study on Spatial Design of Elementary School Based on Ecological Approach)

  • 윤지영;송주은
    • 한국실내디자인학회논문집
    • /
    • 제13권4호
    • /
    • pp.118-126
    • /
    • 2004
  • This study started from the premise that the future elementary school should be designed based on ecological approach in order to restore the emotionality of children. This study aimed at providing a guideline for designing the interior of elementary schools based on ecological approach. Through literature review, the characteristics of ecological architecture and the regulations for green buildings were explored. Also 7 elementary schools which were evaluated as good school design through renowned books representing the ecological characteristics were chosen and analyzed. The results revealed that the school design included natural lighting by roof lighting, natural ventilation, greening, and use of natural materials. This study suggested three categories as a the guideline for the interior space of eco-school design; energy efficiency, greening and sustainability, which included natural lighting, natural ventilation, heating and cooling, planting, materials and water recycling.

Ecoloy개념을 적용한 초등학교 공간디자인에 관한 연구 - 일본 오사카시 초등학교와 부산시 초등학교 사례분석 - (A Study on the elementary school design based on ecological approach - Focused on the shared space of the elementary school of in Osaka Japan and Busan Korea -)

  • 윤지영;송주은
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.136-140
    • /
    • 2004
  • This study starts from the premise that future elementary school should be designed based on ecological approach. In order to restore the emotionality of children, school should provide and protect our natural environment by greening and energy saving. The research was conducted in Osaka and Busan to analyze the present condition of elementary schools in terms of ecology. The shared spaces such as halls, corridors, stairs and rest areas of fourteen schools were chosen and analyzed by the design analysis list. The list included the guidelines including greening, lighting, heating and cooling, ventilation and use of materials. The results showed that Korean schools require void space for more natural lighting, ventilation and insulation, while Japanese schools have problems in use of environmentally friendly materials, natural lighting and interior greening. This study reveals that ecological approach including greening and natural lighting should be considered in future elementary school design to make the school environment more agreeable and economical.

  • PDF

축소모형을 이용한 광선반의 시환경 특성 평가 연구 (Visual Performance Evaluation Study of a Scaled Light-Shelf Model)

  • 조일식;김병수;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.