• Title/Summary/Keyword: Lighting analysis

Search Result 823, Processing Time 0.022 seconds

Analysis of electrical and optical characteristic of surface lighting using organic light-emitting diodes (OLED 면광원의 특성 분석)

  • Kim, Do-Hwan;Na, Jong-Hyuck;Lee, Hyung-Young;Jeon, Sang-Kyoo;Cho, Mee-Ryoung;Choi, Yong-Won;Yang, Seong-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.159-162
    • /
    • 2009
  • Surface lighting using OLEDs for desk/task lighting has been analyzed its electrical and optical characteristic with a fluorescent lamp which has triple wavelength peak. We have confirmed the good possibility of OLEDs for desk/task lighting. Our engineering sample which has fabricated by co-worker has its characteristics which are luminous efficacy 11.781m/W at 509mW, CRI Index 75, CCT 4479K, CRI coordinate x=0.378, y=0.4547, respectively. Addinationly another OLEDs samples are used for compartive analysis in view of desk/task lighting.

  • PDF

Comparative Analysis on Lifetime of Fluorescent Induction Lamp (무전극 형광램프의 수명 비교 분석)

  • Jeon, Sang-Kyoo;Cho, Mee-Ryoung;Choi, Suk-Joon;Rho, Jae-Yeop;Lee, Se-Hyun;Shin, Sang-Wuk;Hwang, Myung-Keun;Lee, Do-Young;Yang, Seong-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.202-204
    • /
    • 2008
  • This paper gives a comparative analysis on lifetime of the fluorescent induction lamp. We have treasured and analysed optical characteristics of circular type fluorescent induction lamps, which has A and B types, to estimate lifetime. In the result of analysis on lifetime, $B_{10}$ lifetime of A and B type lamps are 466 hours and 1,595 hours, respectively.

  • PDF

Analysis of Landscape Preference by the Installation Combination of Lightning in Tunnel based on Conjoint Analysis (컨조인트 분석에 의한 터널 내 조명시설 설치조합별 경관 선호도 분석)

  • Lee, hyeryung;Kum, kijung;Jung, hyunjung
    • International Journal of Highway Engineering
    • /
    • v.14 no.6
    • /
    • pp.111-120
    • /
    • 2012
  • PURPOSES : This study is to suggest suitable lighting facility installation plans by finding out driver's preference for combination of lighting facility installation among landscape factors that affect driver visibility in tunnels. METHODS : SD method is used to extract emotional factors that affect drivers' preference, Components of tunnel lighting facility installation are evaluated through conjoint analysis and it suggested relative importance of attributes and utility values. RESULTS : In the aspects of satisfaction levels of components of tunnel lighting facility installation, Tunnel side, two lows, and solid line arrangement type has the highest level of satisfaction. Extract emotional factors that affect drivers' preference are "safety", "openness" and "amenity." In addition, the result of analyzing relative importance of attributes of tunnel lighting facility shows that numbers of lighting array has the highest importance and lighting facility arrangement has the lowest importance. Result of analyzing partial utility shows that the 2 low type among number of lows, the solid line arrangement type between arrangement types, placing in the middle part among lighting facility arrangement were highly preferred. CONCLUSIONS : In the case of lighting numbers, utility values of the first line and the second line showed us a big difference. Increasing the number arrays in the future reformation of lighting facility installation combination will be effective in enhancing the utility of the driver.

A Study on Developing a Teardrop LED Lighting Fixture and Economic Analysis at Industrial Clean Rooms (산업용 클린룸에서의 Teardrop LED 등기구 개발 및 경제성 분석에 관한 연구)

  • Lhee, Sang Choon;Choi, Yeo Jin;Choi, Young Joon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2013
  • On the electricity consumption in Korea, the lighting sector takes about 17% of annual total electricity consumptions. In the midst of higher interests on energy conservation measures, design and choice of energy-saving lighting fixtures have been more important. With growth of technology-intensive industries like advanced material, semiconductor, and biotechnology from the 1980s, needs for clean room and thus illumination at clean rooms have been increased. In this paper, development, specification, and features of a Teardrop LED(hereinafter TD LED) lighting fixture as replacement of Teardrop florescent lighting one that has been popularly installed at clean rooms were presented. Also we performed the economic analysis of return on investment(ROI) about energy savings by the installation of the TD LED lighting fixture at a new-built clean room. The economic analysis showed that the new-developed TD LED lighting fixture would be able to withdraw the initial installation cost within 4 years. Lastly, improvement directions and development plans of the next TD LED lighting fixture for wider applications at clean rooms were described.

An Analysis on the Outdoor Lighting Situation and Policies in Korea, China, Japan - focused on Seoul, Shanghai, Yokohama- (한국·중국·일본의 도시경관조명 현황 및 정책 분석 - 서울, 상하이, 요코하마를 중심으로 -)

  • Ahn, Hyun-Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.35-42
    • /
    • 2003
  • It is required impressive expression of urban night environment that makes city as the safe pleasant, convenient place for the economic activity, cultural pleasure and landmarks. This study aims to establish the proper direction to the outdoor lighting in Seoul by analyzing and comparing the lighting situation and policies among Seoul, Shanghai and Yokohama. 1986 Asian Game and 1988 Olympic Game became very important role of activation of outdoor lighting in Korea. Then, outdoor lighting were facilitated in the cultural heritages and bridges along Han river. Millenium Light Plan, Outdoor Lighting Field of Seoul Architectural Award, 2002 Lightscape Local Plan, hosting 2002 World Cup have been good opportunities for the improvement of outdoor lighting in Seoul. In China, outdoor lighting was introduced to the city of Shanghai according to the orders of the president in 1988. Outdoor lighting of Shanghai have created unique lighting with beautiful color and intensive brightness under the direction of city government. Outdoor lighting of Shanghai needs the standard of lighting design and improvement of lighting facilities. Outdoor lighting was introduced to Japan with 1964 Tokyo Olympic games. Urban outdoor lighting plan was carried out in Yokohama in 1986. In Yokohama, outdoor lighting of civilian and public facilities have been harmonized. And the city government of Yokohama established the committee of promotion of outdoor lighting in its government to support and manage the outdoor lighting with corporation of civilian organization. As the result of comparative analysis on Seoul, Shanghai, Yokohama, Seoul Metropolitan Government needs the criteria and incentive system of outdoor lighting.

The Characteristics Analysis of substitute LED and CNT Lighting for fluorescent lamp (형광등 대체용 LED조명과 CNT조명에 대한 전기적.광학적특성의 비교고찰)

  • Hwang, M.K.;Lim, J.M.;Shin, S.W.;Rho, J.Y.;Cho, M.R.;Lee, S.H.;Jeon, S.K.;Choi, S.J.;Yi, C.W.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.205-208
    • /
    • 2008
  • In this paper, we have measured and compared the optical and electrical characteristics of LED(light emitting diode) and CNT(carbon nano-tube) lightings. Especially, the IES format files are used for each of the luminaire LlD(luminous intensity distribution) analysis and light level simulation for analyze the maximum, minimum, and average light level. In the future, when CNT and the LED based lighting technology standards are writing, this data will be used in judging.

  • PDF

Analysis of User Preference about the Color Rendering Index, Correlated Color Temperature and Illuminance of LED Lighting in Merchandising Spaces (상업공간에서의 사용자 선호 LED 조명 연색지수와 상관색온도, 조도의 분석)

  • Lee, Su-Jung;Yoon, Hea-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This study aims to recommend the proper Color rendering index (CRI), the Correlated Color Temperature (CCT), and illuminance levels of Light-Emitting Diode (LED) lighting based on the analysis of the criteria of the current CRI, the CCT, and illuminance levels in merchandising spaces with LED lighting conditions. It would be a basic material to apply in line with user preference for LED merchandising lighting. To this end, it examines relevant literature review on the experiments designed to test whether lighting characteristics affect brightness perception, color appearance, and pleasantness. Highly saturated colors appear brighter than low saturated colors. Two lighting applications - grocery and clothing shop - were created in elaborating the effect of LED lighting characteristics of CRI on color appearance and the CCT and illuminance on pleasantness. The findings show that the criteria of CIE Ra<80 are appropriate to provide better color appearance of illuminated products in terms of LED lighting that can enhance color saturation, particularly for the red color. Furthermore, 2700 K and less than 500 lux for grocery, 4000 K and more than 500 lux for clothing shop are found to be the proper the CCT and illuminance levels respectively to bring better preference under LED lighting.

An Analysis on the Luminance Distribution and Subjective Responses on Image of Historic Buildings Illuminated by Outdoor Lighting - Focused on the Namdaemun, Kwanghwamun, Changanmun and Paltalmun - (야간경관조명이 된 역사적 건축물의 휘도분포 및 주관적 반응 분석 - 남대문, 광화문, 장안문, 팔달문을 중심으로-)

  • Ahn, Hyun-Tae;Jeong, in Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.29-36
    • /
    • 2004
  • Designing outdoor lighting on landmarks has been activated in Korea since 2002 World Cup. And outdoor lighting has been important method to create nighttime activities. Especially, historic buildings which are illuminated by outdoor lighting expresses cultural beauty of the heritages in the region. Therefore, this study aims to analyze the outdoor lighting effect of historic buildings with particular reference to four historic buildings - Namdaemun, Kwanghwamun, Changanmun and Paltalmun. For the purpose, luminance of outdoor lighting are measured. Outdoor lighting of the historic buildings were mainly illuminated by the floodlights. In addition, up-lighting and accent lighting were used for expressing the bracket structure. Basements and rooflines are emphasized by floodlighting, and they represented the night image of historical buildings. For the subjective evaluation on the outdoor lighting of historic buildings, outdoor lighting images of four historic buildings - Namdaemun, Kwanghwamun, Changanmun and Paltalmun were photographed. Questionnaire surveys were conducted by hundred and twenty university students of architectural department And collected papers were statistically analyzed by SPSS. Factors that shows outdoor lighting images of historical buildings are as follows; atmosphere, clearness, intimacy, modelling. On the question of general impression of outdoor lighting, Kwanghwamun has got the most satisfactory responses and the next is Changanmun and Namdaemun, Paltalmun. Major variables which related to the 'general impression' of outdoor lighting for historic buildings have been 'dignity', 'match', 'elegance', 'beauty' in the order.

A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building (사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구)

  • Son, Chang-Hee;Yang, In-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

Photometric Analysis of 300w class Electrodeless flood lighting fixture (광원 고정 형태에 따른 300W급 무전극 투광등기구의 설계안 비교 연구)

  • Shin, Hyeon-Jeong;Kim, Jin-Mo;Shon, Jang-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.53-56
    • /
    • 2003
  • Photometric analysis is essential process to make design for 300W Electrodeless flood lighting fixture. But lighting source's unusual shape makes it difficult to fix in and so we supposed two kinds of installation method to solve this matter. One is to place lamp base down and second is to put lamp base side like normal HID lamps. In result, former photometric analysis came to reach a target for similar asymmetric photometric data meanwhile we can not escape work to design complicated reflector. Second analysis reached conclusion that it is more simplified reflector than former. On its lighting fixture's design, the former reflector is new and attractive breaking fixed idea but the latter is only staying in the range of existing HID lighting design.

  • PDF