• Title/Summary/Keyword: Lighting Energy Use

Search Result 125, Processing Time 0.03 seconds

A Study on Spatial Design of Elementary School Based on Ecological Approach (생태적 개념을 도입한 초등학교 실내공간 디자인에 관한 연구)

  • 윤지영;송주은
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.118-126
    • /
    • 2004
  • This study started from the premise that the future elementary school should be designed based on ecological approach in order to restore the emotionality of children. This study aimed at providing a guideline for designing the interior of elementary schools based on ecological approach. Through literature review, the characteristics of ecological architecture and the regulations for green buildings were explored. Also 7 elementary schools which were evaluated as good school design through renowned books representing the ecological characteristics were chosen and analyzed. The results revealed that the school design included natural lighting by roof lighting, natural ventilation, greening, and use of natural materials. This study suggested three categories as a the guideline for the interior space of eco-school design; energy efficiency, greening and sustainability, which included natural lighting, natural ventilation, heating and cooling, planting, materials and water recycling.

A Study on the Limit Analysis of the LED Lighting Subsidy Program Considering the Perspective of Individual Building Clients (건축주 입장을 고려한 LED조명 프로그램의 한계 분석 연구)

  • Hwang, Sung-Wook;Park, Jung-Sung;Chae, Woo-Kyu;Lee, Hak-Ju;Song, Il-Keun;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.18-25
    • /
    • 2013
  • Various DSM (Demand Side Management) programs have been developed and carried out to use the limited energy resources of human-beings reasonably. LED lighting is one of essential DSM programs and the development of technologies is ongoing vigorously. Recently, one-person households have been increased and the electricity consumption pattern is different with conventional households because residents live as a single. On the other hand, owners of the one-person households tend to not prefer to install high efficient appliances due to the cost increasement. Therefore, the existing DSM subsidy programs should be revaluated so that the owners decide to install high efficient appliances.

Inductively Coupled Plasma discharge characteristic of Ne, Ar, Kr mixed gas (유도결합형 플라즈마에서의 Ne, Ar, Kr 혼합가스 방전특성)

  • Her, In-Sung;Choi, Yong-Sung;Lee, Chong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.306-309
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency. also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. At low pressure as mTorr I.C.P make high density plasma easily, is good to maintain discharge, has high ionization and does not have failing lighting and losing ability of electron radiation by oxidation and volatilization of electrodes, because this tape does not have electrodes. This point of I.C.P can use at electrodeless fluorescent lamp in this study ICP display elements and Ar, Ne, Kr are researched for optical characteristic. each gas is looked into optical characteristic, also mixed gases is experiment for optical characteristic.

  • PDF

Development of an Energy Management Algorithm for Smart Energy House (스마트에너지하우스 구현을 위한 에너지 수요관리 알고리즘의 개발)

  • Jeon, Jeong-Pyo;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.515-524
    • /
    • 2010
  • Recently, many actions are taking to accelerate progress toward social consensus and implementation of Smart Grid. Smart Grid refers to a evolution of the electricity supply infrastructure that monitors, protects, and intelligently optimize the operation of the interconnected elements including various type of generators, power grid, building/home automation system and end-use consumers. The most distinguished element will be Advanced Metering Infrastructure (AMI) that will be installed to every end-use consumer's home or building and optimize the energy consumption of the end-use consumer. The key function of AMI is energy management capability that coordinates and optimally controls the various loads according to the operating condition and environments. In this study, we figure out the basic function of AMI in Smart Energy House that can be defined as a model house implementing in Smart Grid. This paper proposes the energy management algorithm that will be implemented in AMI at Smart Energy House. The paper also show how energy saving in Smart Energy House can be achieved applying the proposed algorithm to an actual house model that has mainly lighting, air-conditioning, TV loads.

The Study of Ripple Reduction of the PFC CCM Flyback Converter without Electrolytic Capacitor for LED Lightings using LC Resonant Filter (LC 공진 필터를 이용한 전해 커패시터 없는 LED 구동용 PFC CCM 플라이백 컨버터의 출력 전류 리플 저감에 관한 연구)

  • KIm, Choon-Tack;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.601-610
    • /
    • 2016
  • The light-emitting diode (LED) has been used in a variety of industrial fields and for general 0lighting purposes on account of its high efficiency, low power consumption and long lifespan. The LED is driven by direct current; therefore, an AC/DC converter is typically required for its use. An electrolytic capacitor is generally used for stabilizing DC voltage during use of the AC/DC converter. However, this capacitor has a short lifespan, which makes it a limiting factor in LED lighting. Furthermore, LED lighting requires a dimmable control to enable energy savings and fulfil a growing consumer demand. In this paper, the dimmable single-stage power factor correction (PFC) continuous conduction mode (CCM) flyback converter that employs no electrolytic capacitor is presented. The LC resonant filter is alternatively applied to reduce the 120[Hz] ripple on the output. And the optimum value of the LC resonant filter parameters considering both efficient and performance is analysed. Simulation and experimental results verify the satisfactory operation of the converter.

A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings (업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구)

  • Park, Byung Hun;Kim, Si Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis (민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출)

  • Oh, Jihyun;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.

A Development of Energy saving System using Voltage Adjustment (자동전압조정형 에너지 절약장치 개발)

  • Koo, Heun-Hoi;Byon, Young-Bok;Kim, Yo-Hee;Choi, Jang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.812-814
    • /
    • 1993
  • During the last two decades, we experienced a few of the energy shocks and felt the importance of the energy saving seriously. As our energy reliance on other countries is absolute. We must counter these situations nationally. To save the electric energy, various methods are explored such as the moderation of motor capability, the use of high efficiency system, the supervision of lighting systems, demand monitoring control systems. In this study, we develop a system for electric power energy saving. In Case the receiving point voltage is higher than the required voltage, the system reduce the voltage to an allowable level and by doing so it saves energy and protects the equipments from over voltage.

  • PDF

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Improvement of Underground Parking Garages Lighting in Residential Areas (아파트의 지하주차장의 조명 운영개선)

  • Chang, Soo-Jung;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.163-168
    • /
    • 2004
  • The improvement of perspectives on dark and limited underground space could be an important factor in successful underground space development. Current trend in the apartment underground parking lot requires not only quantitatively energy efficient design and operation, but also qualitative improvement of the space. For this, we need to consider two factors: Firstly, to understand the characteristics of the fluorescent lamp. Secondly, to improve the uniformity ratio of illuminance. In winter season, a way to keep the uniformity and a method not to lower the indoor illuminance level by cold ambient air. Therefore, a change in interval and arrangement of the lighting fixtures is required. Also, in their operation, current time-fixed control method needs to be changed into the control that method considers the use pattern.

  • PDF