• Title/Summary/Keyword: Lighting Energy

Search Result 672, Processing Time 0.028 seconds

A Green LED Sensitivity Lighting System Using Smart Phone (스마트폰을 이용한 그린 LED 감성조명 시스템)

  • Cho, Myeon-Gyun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.2
    • /
    • pp.103-111
    • /
    • 2012
  • This paper introduces a novel concept of 'A Green LED Sensitivity Lighting System' which can automatically estimate QoS(quality of service) and emotional requirements of user using smart phone. And it can intelligently control ambient illumination lamp to conserve electric energy and to satisfy human sensitivity. The proposed system has 4 control modes; emotional lighting, smart lighting, green lighting and realistic lighting modes in order to comfort man's emotion, to maximize work efficiency, to save energy consumption and to make the entertainment more fun, respectively. When we choose green lighting mode for indoor office situations, an elaborate simulation shows that the proposed system with home network can reduce the energy by 50% compared to conventional light control system with a fixed time-based switching.

An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving (에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

A New LED Light Device Lighting Control Algorithm for Optimal Energy Saving (최적의 에너지 효율을 위한 새로운 LED 조명기기 점등제어 알고리즘)

  • In, Chi-Goog;Hong, Sung-Il;Chang, Jeong-Uk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.17-23
    • /
    • 2012
  • In this paper, we were proposed a new LED light device lighting control algorithm for optimal energy saving. The propose lighting control algorithm be to the LED lights devices lighting control by measuring illuminance into multi sensors. And it be to lighting control by inverting of octagon pattern during set-up time. All the LED is lighting when detecting motion by the motion sensor. And, it was designed enable remote management control by communicate with central monitoring center using Zigbee wireless network to measured data from sensors at real time. In this paper, a proposed lighting control algorithm was measured power consumption about the lighting status of LED lighting device using the lighting control program for demonstrate of energy savings effect. The measured result, the lighting method applying proposed algorithm were proved energy savings effect of more 40% more compared to the existing lighting method.

A Study on the Suggestion of a Lighting Control System Applying General Illumination and Technology of User and Location Awareness (전반조명 기반 사용자 및 위치인식기술 적용 조명제어 시스템 제안 연구)

  • Park, Juil;Lee, Haengwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.527-536
    • /
    • 2015
  • Studies for the reduction of lighting energy have been done using technologies such as user and location awareness. However, the focus of current research on location-based lighting control has been on energy reduction, which can lead to other issues including an imbalance in indoor illumination. This study proposes a lighting control system applying general illumination and technology for user and location awareness. The proposed lighting control system reduced lighting energy by 72.1%, 66.5% and 62.3% for 1, 2 and 3 users, respectively, compared to the On/Off lighting control system. This lighting control system causes an increase in lighting energy of 35.8% and 10.9% for 1 and 2 users compared to the lighting control system with user and location awareness, while a reduction of 9.4% was seen for 3 users. This means that the proposed system provides more effective energy reduction for a room with multiple occupants as it is based on the general lighting control scheme. The lighting control system applying general illumination and technology of user and location awareness improved the uniformity factor by 32.0%, 39.4% and 33.4% for 1, 2 and 3 users, respectively.

Effect of Lighting Saving Using High Efficiency Reflector (고효율 반사갓을 이용한 등기구 저감효과)

  • Cho, Huyn-Kyung;Kim, Jae-Chul;Jung, Seung-Bock;Im, Sang-Kug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

A Study on Energy Savings Analysis by Controling LED Lighting according to the Change of the Amount of Daylight (주광량의 변화에 따른 LED조명 제어를 통한 에너지 절감량 분석에 관한 연구)

  • Ham, Won-Tae;Chae, Soo-Yong;Han, Soo-Bin;Kim, Heung-Geun;Jung, Hak-Guen
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.522-528
    • /
    • 2012
  • Currently, the energy consumption of electric lighting in an office building is accounted for more than 30% of the total energy consumption. In order to reduce the energy consumed by the indoor lighting, the daylight as a natural energy resource can play an important role in energy savings. The daylight can have positive impacts on improvement of work efficiency and productivity, and also make people feel more psychologically stable. Moreover, by using the daylight, we can definitely reduce the energy consumption in office buildings. Thus, the purpose of this study is to determine the LED dimming ratio depending on the ratio by calculating the amount of artificial illumination required according to the change of daylight by using the light simulation software that can quantify and visualize the performance of daylight. As a result, the energy savings could be obtained up to 30%.

  • PDF

Artificial Lighting Energy Saving by Daylighting in Office Building (사무소건물에서 자연채광에 의한 조명에너지 절약의 평가)

  • 임병찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.608-613
    • /
    • 2004
  • Artificial lighting accounts for a significant portion of the energy use in office buildings. Therefore, daylighting is considered one of the fundamental design features of energy-efficient buildings. However, complex daylighting simulation tools are not suitable for most designers to help in the decision-making process. This paper provides the results of a simulation analysis to determine the potential energy savings of daylighting effects reducing electrical energy consumption for office building. A whole building simulation tool is used to determine the effects of daylighting on lighting electricity use as well as total electricity use for typical office buildings. It was determined that daylighting does not provide significant additional lighting energy savings when glass transmittance is increased over 0.7 A simplified method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.

Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions (소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.

Performance of heat sinks for LED luminaires in office buildings - Focused on the variation of air flow rate in duct - (사무소건물의 LED조명기구 방열장치의 성능 분석 연구 - 덕트 내 유량변화 중심으로 -)

  • Park, Ji-Woo;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.81-86
    • /
    • 2014
  • In recent years, many researchers have considered the building energy consumption reduction accordingly to deal with abnormal climate changes and greenhouse gas reduction. However, the lighting energy use ratio has increased in spite of the development of the high efficiency lighting device. Therefore, the study aims to produce the LED lighting applications for the effective lighting heat removal by using the heat characteristics of LED lighting and analyzing the heat removal effect. In order to increase radiant heat efficiency, the heat pipe and heat sink was attached on PCB as LED lighting applications. Experiment was conducted to verify the temperature and air velocity of inside duct: thermocouples, anemometer. The heat removal effect of LED lighting applications was measured by observing the temperature of the lighting applications and the change of air velocity in duct. The experiment shows that the temperature change in the duct according to air velocity was $0.9{\sim}5.8^{\circ}C$. It is also concluded that heat removal was calculated from 33 to 81W.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.