• Title/Summary/Keyword: Lighting Energy

Search Result 681, Processing Time 0.023 seconds

Proposal of the Prediction Equation for Interior Daylight Illuminance (실내 주광조도 분포 예측식의 제안 및 검증)

  • Park, Woong-Kyu;Park, Tae-Ju;Kang, Gyu-Min;Lee, Sang-Yup;Song, Doosam
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.114-123
    • /
    • 2013
  • In these days, most of the office buildings are being required to save energy for maintenance. lighting system constitutes 20% to 30% of the total annual electrical energy consumption in office buildings. As an energy saving strategy for lighting system, dimming control system based on illuminance sensors came into use. But the system is accompanied with many illuminance sensors to control lighting and needs a lot of initial investment. In this study, the prediction equation for indoor daylighting illuminance distribution is proposed through the review for conventional research results and field measurements. The proposed equation was verified by the comparison between predicted results and field measurement results. The developed prediction equation for daylighting can be used to control the indoor illuminance level with the limited sensor when dimming control system is operated.

Study on Effective EERS Savings Calculating Method through Analysis of Energy Consumption of Electric Motor & Lighting Devices (전동기와 조명기기의 에너지사용 분석을 통해 효과적인 EERS 절감량 산정을 위한 주요인자 도출 연구)

  • Yeom, Jeehoon;Choi, Hanho;Lee, Hyunwoong;Park, Sungwoo;Kim, Changsik;Hahn, Seunghee
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-41
    • /
    • 2019
  • It is essential to introduce EERS (Energy Efficiency Resource Standards) according to the trend of the era in which energy saving is emphasized, and it is time to settle down in a stable manner. Electric motors and lighting devices, which account for more than 60% of the nation's electricity use, are the most effective items of the EERS. And accurate methods of calculating savings must be preceded. In this study, the operation rate and load rate are measured through the demonstration of energy use at 400 businesses and the measured rates are used for EERS savings calculation. The results imply that the proposed method can be successfully applied to calculate cost-effective and reliable energy savings.

A New Economic Evaluation for Demand-Side Resource using Lighting Dimming Control for the Electricity Suppliers in Competitive Electricity Markets (조광제어를 활용한 전력판매회사 관점의 수요관리자원에 대한 새로운 가치평가 연구)

  • Kim, Jin-Ho;Kim, Seong-Cheol;Nom, Young-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.8-15
    • /
    • 2009
  • In this paper, a new demand-side evaluation for the technical potential of lighting dimming control and its applications in electricity markets have been presented. The California standard practice test has been widely used to estimate the economic value of demand-side resources. However, as the advent of deregulation and restructuring of power industry, the California test has been facing some limitations to adopt in the new market environments. In particular the conventional DC test is appropriate for the traditional vertically integrated utility, not for the restructured unbundled utility. Thus, this paper presents a new method to evaluate the economic value of demand-side resource, especially of controllable lighting dimming resource in terms of the energy service provider in market environments. We, therefore, first estimate the technical potential of the lighting dimming control and evaluate the value of the lighting dimming control based on the Korean electricity market data in 2006. The study result shows that the lighting dimming control is a cost effective option for the energy service provider.

A Study on the Development of Building Control and management System -Focusing on the Lighting Control and Monitoring system- (빌딩 제어 및 관리 시스템 개발에 관한 연구 -조명 제어 관리 시스템 구축을 중심으로-)

  • Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.110-118
    • /
    • 2007
  • Technology has been viewed at various stages of civilization as leading to future progress. The building, its services systems and management of the work process all contribute to the well-being of people within an organization. Productivity relies on there being a general sense of high morale and satisfaction with the workplace. Now buildings are considered as providing a milieu for human creativity. Flexibility, adaptability, service integration and high standards of finishes offer an intelligence threshold. Building Automation System(BAS) - controlled lighting systems may offer incremental energy saving. Conventional Lighting control systems often control equipment in a single room or over the limited area, because they are centralized control systems, which means that all the controlled circuits must be wired to a single control panel. The computers used by these systems are typically dedicated microprocess that perform only lighting control functions. By comparison, modern Building automation systems are distributed control system, which means that their computing hardware and software are distributed as a network that microprocessor-based control modules and standard PC. PLC(Programmable Logic controller) is extensible virtually without limits, so that all the lighting in a facility can be controlled by single, unified system - the same system that also can control and monitor the building's HVAC, security, and manufacturing processed, elevators, and more. A Building automation system can control light using schedules, manual controls, occupancy sensors, and photosensors, either singly or in combination. Building Lighting control and monitoring system will be for a energy saving and efficient building management system.

Development of 80W LED Lighting Equipment for Broadcasting System (방송시스템용 80W LED 조명장비의 개발)

  • Lee, Dong-Yoon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.506-511
    • /
    • 2017
  • LED lighting, which many companies are pursuing commercialization, is a representative green energy technology. However, the LED lighting for broadcasting image should have high output and easy portability compared with general LED lighting devices for street lamps, advertisement or transportation devices. Therefore, while shooting a broadcast image if you use LEDs as a substitute light source for halogen lamps and fluorescent lamps that are large in size and uncomfortable to handle it is expected that the lightening of the equipment will activate the broadcasting image lighting equipment industry. After considering the mass production of the LED module board and the SMT production size of the chip mounter, the board size was determined considering the overall size of the product by model. In this paper, four 20W LED boards are arranged vertically in order to produce an 80W board. In other words, by sharing LED module board size by model, high power LED lighting equipments of 120W and 200W can be selected as an increase in the number of boards.

Performance Evaluation of Smart Street Lighting Systems Applying the PFI Model

  • Hung-Yu Chou;Yu-Te Wei;Yu-Ting Lai;Jun-Teng Zhuang;Jun-Xi Liu;Wen-Chin Chang
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.1278-1278
    • /
    • 2024
  • Private Finance Initiative (PFI) involves long-term contracts where private entities invest in the construction and maintenance of street lighting facilities. The current implementation of PFI Smart Street Lighting Systems faces challenges in the fulfillment process, including discrepancies in quantities, coordination of power variations, delays in the deployment of smart systems, and issues with performance indicator scoring. These challenges disrupt the smooth execution of contractual obligations. Nevertheless, the adoption of intelligent systems in street lighting presents significant advantages in reducing energy consumption, extending the lifespan of fixtures, and enhancing maintenance efficiency. This study aims to analyze an ongoing project, applying the Fuzzy Analytic Hierarchy Process (FAHP) to identify crucial PFI indicators and their weights. The study explores areas of improvement in the project compared to traditional street lighting, aiming to provide solutions to the mentioned challenges. The results indicate that indicators such as PS3 (Lighting Service Continuity) with a weight of 0.384% and PS4 (Smooth Operation of the Smart Street Lightings Management System) with a weight of 0.274% have the highest impact on service performance. Additionally, the project involves replacing 162,000 streetlights, resulting in a yearly energy consumption reduction of approximately 70%, a decrease in monthly maintenance time from an average of 48 hours to 15 hours, and an expected reduction of 900,000 tons in carbon emissions during the project period. Value for Money (VfM) analysis suggests an annual reduction in government expenditures of NTD 66 million. This reveals that implementing PFI model is more advantageous than traditional street lighting procurement, as it allows the government to leverage contractor financing and alleviate the initial high costs of streetlight replacement, thereby reducing the overall costs of streetlight establishment and maintenance.

Effects of LED Lamps for Replacement of Metal Halide Lamp in Roadway Lighting Environment (LED램프와 메탈램프가 도로조명환경에 미치는 특성 비교평가)

  • Lee, Myung Gi;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.47-52
    • /
    • 2013
  • The problems of light pollution first became an issue in the 1970s when astronomers identified the degradation of the night sky due to the increase in lighting associated with development and growth. As more impacts to the environment by lighting have been identified, many attempts have been made for reducing light pollutions. To prevent light pollution and increase energy efficiency, Seoul Metropolitan Government(SMG) replaced metal halide road lighting to LED luminaire in four arterial highway in Seoul. The present study compared the lighting characteristics of metal halide and LED luminaire in terms of Korea Standard for road lighting(KS A 3701) and BUG rating from Illuminating Engineering Society of North America(IESNA). The results showed that LED luminaire increased road surface luminance up to 2 times in average compared to the metal halide environment. Also, LED luminaire reduced the glare value by 2 times and luminous flux over 50% than the metal halide luminaire. In comparison with the BUG ratings, LED luminaire rated 1 degree lower for the backlight ratings and 3-4 degrees lower for the uplight ratings. The measured values testified that the LED luminaire is effective for roadway lighting and light pollution reduction.

A Study on the Luminous Environments of Architectural Building for Improvement of Night-Scape in Coastal Resort - Focused on the Gyengpo Park - (해안 휴양지의 야간경관 개선을 위한 건축물의 조명환경 연구 - 경포도립공원을 중심으로 -)

  • Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.3
    • /
    • pp.27-34
    • /
    • 2008
  • Recently, the outdoor lighting of architectural Facade has increased for the improvement of night-scape in urban and coastal resort. The purpose of this research is to analyze lighting characteristics; Luminance, Illuminance, Color Temperature, Chromaticity in Gyengpo Park of Eastern famous coastal resort. The result of this paper is as follows: 1) The Luminance ratio was measured that compare to the 1:10 criterion(IESNA) was in excess to the most building except "K". Because of these condition, Luminance environments was injurious to visual health the overuse of the outdoor lighting or glare to the eyes. 2) The level of vertical Illuminance value was insufficient 33.3% among the cases of survey with 4Lux standard of CIE. 3) The kinds of outdoor lighting of BLDG were increased lighting emitting diode(LED), metal halide(MH) instead of reduction trend of neon, fluorescent light, halogen. As the crisis of Energy resources we will be investigate adapt method of outdoor lighting, which design is based on economical efficiency by the use of optimum lighting.

  • PDF

Investigation Research for Apartment House Lighting Equipment Standard Establishment (공동주택조명 설비 기준 설정을 위한 조사 연구)

  • Kim, Dong-Kwan;Lee, Sun-Hyung;Lee, Kyung-Sup;Kim, Jang-Yuol;Chon, Yeon-Soo;Chung, Hun-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.562-564
    • /
    • 2001
  • Current interior lighting design way that is consisting uniformly by designer's experience or simple capacity calculation diversifies according to standard of living elevation and there is problem that do not reflect been individualising resident's change request in lighting plan, design properly. Therefore, because this resident's request, enough judgment data that is worth reflecting dissatisfaction item in design concretely or standard is not saved up in business post, had gotten into bottleneck at lighting design. Diagnose resident's consciousness and feedback degree about interior lighting to existent apartment complex in this research and examined improvement plan. As a result, in the case of illumination, wanted higher brightness and showed reason that is most Affirmativ about order way of lighting fixtures. The reason is because can select registration nine that want by oneself directly. Plan qualitative elevation of house lighting environment making lighting image which is coincided in our real condition, and is thought to reflect various resident's character, fondness in design and solved dissatis faction.

  • PDF

Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position (확산필름 부착 위치에 따른 광선반 성능개선 연구)

  • Park, Eunsu;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.