• 제목/요약/키워드: Lighting Efficiency

검색결과 507건 처리시간 0.028초

낮은 전압 스트레스의 스위치를 가지는 1-stage 비대칭 LLC 공진형 컨버터 (1-stage Asymmetrical LLC Resonant Converter with Low Voltage Stress Across Switching Devices)

  • 김춘택;김성주;나재두;김영석
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1101-1107
    • /
    • 2013
  • A light emitting diodes(LED) lighting has been increasingly used due to its low power consumption, long life time, high efficiency, and environment friendly characteristics. Also various power converters has been applied to drive these LED lighting. Among many power converters, a LLC resonant converter could be applied for LED lighting because of its high efficiency and high power density. Furthermore, the function of power factor correction(PFC) might be added. In this paper, 1-stage asymmetrical LLC resonant converter is proposed. The proposed converter performs both input-current harmonics reduction and PFC using the discontinuous conduction mode(DCM). The proposed 1-stage LLC resonant converter approach has the lower voltage stress across switching devices and achieve the zero voltage switching(ZVS) in switching devices. To verify the performance of the proposed converter, simulation and experimental results from a 300[W] prototype are provided.

TRIAC위상 제어 조광기에서의 LED구동을 위한 Single-Stage 준 공진형 PSR(Primary Side Regulation) PWM 컨버터 (Single-Stage Quasi Resonant Type PSR(Primary Side Regulation) PWM Converter for the LED Drive in TRIAC Phase Controlled Dimmer)

  • 한재현;임영철;정영국
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.84-94
    • /
    • 2013
  • In case when the existing TRIAC phase controlled dimmer is drove for the LED lighting equipments, there are many problems such as the LED flicker in low phase-angles, the acoustic noise and elements damage by increase of the peak voltage in the input filter capacitor, mulfunction by insufficiency of the TRIAC holding current, and the abnormal oscillation by LC resonant. In this paper, we proposes the single-stage quasi-resonant PSR(Primary Side Regulation) PWM converter, and the design, the simulation and experiment are performed. As a result, it could confirm that the proposed PWM converter is the lighting equipments for LED drive which can alternate the existing 60W class incandescent bulbs and it has the high drive performance of the efficiency 80% and over, the power factor 0.95 and over under the normal voltage 220V. Finally, total harmonic distortion(THD) is gratified with a standard[1] of the lighting equipments and the durability is evaluated as the high reliablilty of 150,000 hours and over.

Automation of Roadway Lighting Illuminance Measurement

  • BAO, Jieyi;HU, Xiaoqiang;JIANG, Yi;LI, Shuo
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.705-711
    • /
    • 2022
  • Roadway lighting is an integral element of a highway system. Luminaires on roadways provide viewing conditions for drivers and pedestrians during nighttime in order to improve safety. It is time-consuming and labor-intensive to manually measure roadway illuminance at predetermined spots with a handheld illuminance meter. To improve the efficiency of illuminance measurement, a remote-control electrical cart and a drone were utilized to carry an illuminance meter for the measurements. The measurements were performed on the marked grid points along the pavement. To measure the illuminance manually, one person measures illuminance at each grid point with the handheld meter and another person records the illuminance value. To measure the illuminance with the remote-control cart, the illuminance meter is attached to the cart and it measures illuminance values continuously as the cart moves along the grid lines. With the drone, the meter records the illuminance continuously as the drone carries the meter and flies along the grid line. Because the drone can fly at different heights, the measurements can be done at different altitudes. The illuminance measurements using the cart and the drone are described in detail and compared with manual measurements in this paper. It is shown through this study that automated measurements can greatly improve the efficiency of roadway illuminance data measurements.

  • PDF

축소모형을 이용한 광선반의 시환경 특성 평가 연구 (Visual Performance Evaluation Study of a Scaled Light-Shelf Model)

  • 조일식;김병수;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

원자력 발전소 주제어실(MCR) 환경 개선에 관한 연구 - 조명환경을 중심으로 (A study on improvement of nuclear power plant main control room environment - focus on lighting)

  • 류제혁;변승남
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2004년도 춘계공동학술대회 논문집
    • /
    • pp.664-667
    • /
    • 2004
  • In nuclear power plant, the main control room(MCR) plays a leading and important role, so it is the core to have its design well operater-centered, both physically and cognitively. This paper especially analyzes focusing on lighting MCR environment and shows alternatives. It will lead to improve work efficiency and to care operator's sight. In conclusion, reducing operator's stress, fatigue and increasing safety, comfort.

  • PDF

지능형 조명 제어 시스템용 LED 단말기 개발 (A Study for Designing of Intelligent Lighting Control LED Apparatus)

  • 유수엽;이기헌
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2008
  • This paper is a report of designing for LED lights driver unit. The main purpose of driver designing is high electrical efficient performance and intelligent control LED driver. This LED driver can be used for intelligent light control. This product expects to improve the light control by dimming instead of interlace on/off light control that increases the social cost such as car accidents and etc.

  • PDF

실내 환경 집중 및 휴식상황에서의 뉴로-퍼지를 통한 LED 감성조명 시스템 설계 (Design of Neuro-Fuzzy LED Emotional Lighting System for Concentration and Resting Situations in Indoor Environment)

  • 강은영;김효준;박건준;김용갑
    • 한국정보통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.558-566
    • /
    • 2015
  • 차세대 조명광원인 LED가 급격하게 발전하고 저 전력, 고효율, 장수명의 장점을 가지고 있어 LED를 이용한 조명에 관심이 높아지고 있다. LED를 이용하여 감성조명을 구현하게 되면 기존의 단색의 조명과는 다르게 빛의 3원색을 이용한 모든 색상을 구현할 수 있다. 이러한 장점으로 인간의 감정까지 다스릴 수 있는 LED 감성조명이 지속적으로 개발되고 있다. 본 논문에서는 실내 환경에서의 집중 및 휴식상황에 맞는 색상을 추출하고 사용자가 느끼는 온도의 색상과 배합하여 상황과 온도에 대한 LED 감성조명을 표현하기 위해 알고리즘을 설계한다. 그리하여 뉴로-퍼지시스템을 이용하여 설계된 LED 감성조명은 사용자에게 집중 및 휴식에 대한 감성에 효과적인 영향을 나타낼 수 있을 것이다.

비냉각형 고효율 태양광 채광시스템 및 응용에 관한 연구 (Un-Cooled High Efficient Solar Lighting System and its Application)

  • 이호열;김명진;신서용
    • 한국통신학회논문지
    • /
    • 제36권11B호
    • /
    • pp.1394-1402
    • /
    • 2011
  • 본 논문은 포물 반사경 방식 및 프레넬 렌즈 방식을 이용한 태양광 집광장치 및 이의 응용에 관한 것이다. 본 시스템은 대구경 반사경과 더불어 2차 광학계를 도입하여 광섬유로 입사되는 빛의 입사각을 광섬유의 개구수보다 작게 함으로써 집광효율을 극대화하였다. 또한 광섬유 단면에 입사하는 빛의 에너지 밀도를 낮게 하기 위해 광섬유 다발 직경 크기와 동일한 평행광이 광섬유로 입사되게 함으로써 반사경을 사용한 집광 시 문제가 되는 열발생 문제를 별도의 냉각장치 없이 근원적으로 차단하였다. 최근 각광받고 있는 식물공장에 주로 쓰이는 LED와 같은 인공광원 대신 본 연구에서 개발한 태양광 집광장치를 식물공장에 적용하여 인공조명과 태양광의 혼합조명장치를 통해 식물을 재배하였다. 그 결과 낮 시간대에 인공조명에 소요되는 전기에너지를 대폭 절감할 수 있었다. 혼합조명장치에서는 조도센서를 활용하여 항상 일정량의 빛이 식물에 제공되도록 LED등의 밝기를 조절하였다. 하루 10시간 기준으로 100형 규모의 식물공장에 태양광 채광시스템을 적용할 경우 한 달에 약 28,080KWh의 에너지 절감효과가 있다.

광학적 열적 최적화를 통한 6인치 다운라이트 설계 (The Design of 6 inch Down-light by Optimization of the Optical and the Thermal Properties)

  • 김성현;정영기;서범식;양종경;박대희
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1178-1182
    • /
    • 2011
  • The best methods for distribution controled of LED lighting fixtures is control to designed LED chip array, lens and reflector. However, lens design need distribution design to reflector for low-wattage LED lighting because of difficulty of production and reduction of light efficiency. In addition, it needs maximize of thermal performance to improve the efficiency and reliability of device. As a result, for the height of reflector 40[mm] and Inclination 25[$^{\circ}$], we can see the best distribution properties, and, in the thermal properties, junction temperature MCPCB 62.9 [$^{\circ}C$], FR4 PCB 89.6 [$^{\circ}C$], FR4 PCB from Via-hole is 63.1 [$^{\circ}C$]. it may improve for thermal properties for makes the Via-hole.