• 제목/요약/키워드: Lighting Economic Evaluation

검색결과 16건 처리시간 0.021초

BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가 (An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion)

  • 박성철;하주완;김환용;송영학
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발 (Development of detachable air-cap module for improving the performance of windows)

  • 서범동;이행우;서장후;김용성
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.

LED 조명의 광원별 최소 분광분포를 사용하여 자연광 색온도를 재현하는 방법 (A Method of Reproducing the CCT of Natural Light using the Minimum Spectral Power Distribution for each Light Source of LED Lighting)

  • 김양수;오승택;임재현
    • 인터넷정보학회논문지
    • /
    • 제24권2호
    • /
    • pp.19-26
    • /
    • 2023
  • 인간은 자연 빛에 적응하고 진화해왔으나 현재는 실내 생활의 비중이 높아짐에 따라 생체리듬 교란의 문제가 유발되었다. 이의 해결을 위해 일출~일몰간 다채롭게 변화하는 자연광의 색온도를 재현하는 조명이 연구되고 있다. 자연광 색온도의 재현을 위해서는 색온도가 다른 다수의 LED 광원을 사용하여 조명을 제작한 후 수백에서 수천 단계의 광원별 인가전류의 조합에 대한 광특성을 측정 및 수집하여 제어지표 DB를 구성하고 광특성 매칭 방법을 통해 조명을 제어하였다. 이러한 제어 방법은 인가전류의 조합 단계를 세밀하게 할수록 많은 시간 및 경제적 비용이 발생한다는 문제가 있다. 이에 본 논문에서는 LED 광원별 최소 분광분포로 보간 및 조합 연산을 수행하여 자연광 색온도를 재현하는 방법을 제안한다. 먼저 색온도가 다른 광원 채널로 구성되고 각 채널별 256단계의 인가전류 제어 기능을 구현한 LED 조명을 대상으로 채널별 5개의 최소 분광분포(Spectral Power Distribution, SPD)를 실측·수집한다. 이후 수집한 SPD를 대상으로 각 채널별 256단계의 SPD를 생성하는 보간 연산을 수행하고, 채널별 SPD의 조합 연산을 통해 LED 조명의 모든 제어 조합에 대한 SPD를 생성한다. 생성된 SPD를 통해 조도와 색온도를 산출하여 제어지표 DB를 구축한 후 매칭 기법을 통해 자연광의 색온도를 재현한다. 성능 평가에서는 실내 권장 조도 기준을 충족하면서도 평균 오차율 0.18%의 범위 내에서 자연광의 시간별 색온도를 제공하였다.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

학교시설 디자인 품질지표에 대한 설문 연구 - 교사, 학교직원, 교육청담당자를 중심으로 - (A Study on Survey Research Design Quality Indicators for the Educational Building - Focused on Teachers, School Personnel and Education Office Supervisor -)

  • 조경식;아이게림
    • 교육시설 논문지
    • /
    • 제25권5호
    • /
    • pp.3-12
    • /
    • 2018
  • The purpose of this study is to examine the degree of appropriateness of using design quality indicators for the educational building, and complements for design quality indicators. For doing this, each items of the Korean educational building design indicator was validated by teachers, school staff and an education officer. First, School Personnel and Teachers considered indicators for the classroom designed for general subjects as being valid. However, in terms of indicators for the outside space, they thought of them as not being valid. In particular, it seemed that school staff would have a passive attitude toward the open of the school facility for the local society. It is judged that there happens an adverse effect caused by the open of the school facility for the local society in the educational environment of the school. Second, Education Office Supervisors thought that eco-friendly indicators, LED lighting, an outer wall, and widows and doors had a high validity. On the contrary, he viewed the validity of a rainwater retention basin as being low, which was likely because he rarely had expertise on the construction. When it comes to the indicator of technology capability, ultrahigh-speed information network was seen as being valid, and the indicator of economic feasibility had high validity on maintenance and durability. Third, compared to groups of Teachers and School Personnel, the group of education officers presented high validity of indicators. Validity of indicators might be differently showed because different items on indicators were measured. However, it is speculated that Education Office Supervisors mostly acknowledged the validity of indicators. Fourth, a majority of Teachers, School staff, and Education Office Supervisors were favor of the system of the evaluation accreditation for school facilities since it played a guide role in improving the quality of school. In order to settle the system of the evaluation accreditation for school facilities, it is most important that institutions in the local society which are publicly reliable should participate in the phase of designing the system of the evaluation accreditation for school facilities. In sum, overall respondents agreed with the system of the evaluation accreditation for school facilities but were aware that reliable organizations in public would need to take part in planning the system of the evaluation accreditation for school facilities from the beginning.

방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구 (The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building)

  • 김배영;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.