• Title/Summary/Keyword: Light-weight aggregate

Search Result 97, Processing Time 0.029 seconds

Applicability of inorganic waste as binder at manufacturing of Light weight aggregates using high content sewage sludge (하수슬러지 인공경량골재 제조를 위한 무기계 폐기물의 점결제 적용성 평가)

  • Kim, Dug-Mo;Mun, Kyoung-Ju;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.157-160
    • /
    • 2005
  • The purpose of this study is to efficiently treat the sewage sludge discharged from sewage treatment plants and evaluate the feasibility of the manufacture of lightweight aggregates(LWA) using a large quantity of sewage sludge and inorganic waste binder ;f1y-ash, waste-stone, tailing, phosphogypsum. Then they were burned in different soak temperatures from 1190$^{circ}C$ to 1290$^{circ}C$ with fixed soak time and heating rate at 5 minutes and 20$^{circ}C$/min respectively in order to produce lightweight aggregate (LWA). Experiment were generated to evaluate the quality of LWA as well as the relationship between burning condition and product's quality.

  • PDF

Hydration Properties of High-strength Cementitious Composites Incorporating Waste Glass Beads (폐유리발포비드를 혼입한 고강도 시멘트 복합체의 수화 특성)

  • Pyeon, Su-Jeong;Kim, Gyu-Yong;Lee, Sang-Soo;Nam, Jeong-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.74-79
    • /
    • 2022
  • In this study, the effect of a sudden decrease in internal humidity and a decrease in hydration level due to the tight internal structure of high-strength concrete and cement composites was investigated. To verify the change in the internal Si hydration, waste glass foam beads were used as a lightweight aggregate, and the internal unreacted hydrate reduction and hydrate formation tendency were identified over the mid- to long-term. Waste glass foam beads were mixed with 5, 10, and 20 %, and were used by pre-wetting. As the mixing rate of the waste glass foamed beads increased, the strength showed a tendency to decrease. In addition, when the mixing amount of pre-wetted waste glass foam beads increases inside through XRD analysis, TGA analysis, and Si NMR analysis, it is judged that the hydration degree of internal Si is different because moisture is supplied to the paste.

An Experimental Study on the Freeze-Thaw Resistance of High-Strength Light Weight Aggregate Concrete (고강도 경량골재콘크리트의 동결융해 저항성에 대한 실험적 연구)

  • 한상묵;최세규;김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.125-132
    • /
    • 1998
  • 경량골재 콘크리트의 내구성과 경제성에 대한 인식 부족으로 조경재료나 인공토양 둥 구조부재 이외의 분야에 사용되고 있는 국내 실정에 비해서, 구미 여러나라에서는 고강도 경량골재를 장지간 교량과 고충건물에 사용하고 있다. 경량골재 콘크리트는 구조물의 재료비 단순비교에 있어서도 경제성이 있을 뿐만 아니라, 자중감소로 인한 구조적, 기하학적 장점도 있으며, 또한 고강도 경량골재의 개발로 경량골재가 가지고 있는 여러 문제점을 해소하여 사용성과 내구성에 있어서 보통골재 콘크리트와 큰 차이가 없는 상황이다. 그러나국내에서 생산된 경량골재는 닫힌 공극보다 열린 공극을 많이 내포하고 있어 수분흡수가 많고, 특히, 동결융해에 대한 내구성에 취약한 문제점을 가지고 있다. 본 논문에서는 내동해성 향상을 위해 10종류의 고강도 경량골재 콘크리트 공시체를 제작하여 실리카 흄, 물.시멘트비, AE제, 강섬유 등을 실험 변수로 하여동결융해 실험을 수행하였다. 연구결과 실리카흄, 물.시멘트 비는 어느 정도 내동해성을 향상시키지만 근본적인 해결방안이 되지 못하며, AE제를 첨가한 공시체와 강섬유를 사용한 공시체는 동결융해 내구성 지수가 90%이상으로 측정되어 내동해성을 개선시킬 수 있는 요소로 나타났다.

A Study on Method of Construction for Foamed Concrete adding EVA Chip that improves the Resistance of Cracking and Capability of Insulating (크랙저항성(抵抗性)과 단열성(斷熱性)을 향상(向上)시킨 EVA칩 첨가 기포콘크리트의 려공법(旅工法) 연구(硏究))

  • Lee, Jong-Shik;An, Jung-Chan;Lee, Jong-Hak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.5-9
    • /
    • 2007
  • The construction method for Foamed-Concrete has not been important due to following process of construction work. However, according to the code about enhance of energy saving design policy and impact noise, noised isolation has been used in construction site so that the resistance for cracking and capability for insulating of Foamed-Concrete has been required. Therefore, new alternatives are demanded. Optimum mixing design, which can get the improvement of insulation and resistance of crack for Foamed-Concrete adding EVA chip, was derived and also the device, applying to construction site, was invented to equalize quality. This device can measure quantity of all input and placement, and show up the sum of placement and mixing design on a touch screen. This valuable construction method is friendly environment and recycling method because of using EVA chip, by-product of an EVA insole scrap burned or embedded, as a light-weight aggregate.

  • PDF

The Physical Properties of the Block Using Flame Resistant EPS Wastes (폐 난연성 EPS의 혼합조건에 따른 재생골재 블록의 물성에 관한 실험적 연구)

  • Cho, Kwang-Hyun;Kim, Ji-Hyun;Chung, Chul-Woo;Lee, Jae-Yong;Lee, Soo-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.152-153
    • /
    • 2013
  • Based on the Fire Service Act of mandatory provision, new buildings are strictly forced to use fire protection materials. Flame resistant EPS is one of those materials. Unlike conventional EPS that can be fused to make EPS ingot and be recycled for various purposes, flame resistant EPS waste cannot be recycled due to the presence of protective coating that is applied to increase the fire protection properties of EPS. A suitable alternative that can process large amount of flame resistant EPS wastes needs to be developed, and one of the possible alternative is to use them as construction materials. In this research, experiments were designed to observe whether the flame resistant EPS wastes can be utilized as partial replacements of fine aggregates in cement mortar. The replacement ratio of waste EPS was varied, and its effect on compressive strength and absorption capacity was investigated. According to the experimental results, both compressive strength and absorption capacity met the Korean Standard specification for cement bricks and blocks, indicating that flame resistant EPS wastes can be used for construction purposes.

  • PDF

Temperature and humidity characteristics of waste glass aggregate-based vegetation blocks using smart environmental sensor (스마트 환경 센서를 활용한 폐유리 골재 기반 식생블록의 온/습도 특성)

  • Gil, Min-Woo;Kim, Gyu-Yong;Pyeon, Su-Jeong;Choi, Youn-Sung;Park, Jong-Yeop;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.51-52
    • /
    • 2023
  • Recently, heat island and dry island phenomena occur frequently due to land surface development and excessive energy consumption in urban areas. As a result, the surface temperature of the building and the entire temperature of its surroundings are increased, and as a result, the durability of the building is rapidly deteriorated. In order to suppress these causes, a method of maintaining the temperature of road heating wires was implemented as a temporary measure, but this did not predict climate change. Therefore, this study is a method to measure the compressive strength, density, and thermal conductivity of light weight concrete using waste glass foam beads. After fabricating a simple chamber, the temperature and humidity of the inside and outside were measured with an Arduino device in consideration of external factors. Therefore, if waste glass foam beads made through proper mixing are constructed in the urban center, the quality of the urban can be improved.

  • PDF

An optimal mix design of sound absorbing block on concrete ballast in urban train tunnel (도시철도 터널내 콘크리트 도상용 흡음블럭의 최적 배합설계)

  • Lee, Hong-Joo;Oh, Soon-Taek;Lee, Dong-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.75-82
    • /
    • 2016
  • As spreading of train concrete ballast leads to the increase resounding friction noise, an porous sound absorbing block is applied in urban train tunnel as a counterparts against the friction noise. Three steps of major variables tests for an optimal mix design of the block are conducted to pursue the light weight of the block. Pilot property tests of the block for the cases of the fly-ash only as lightweight aggregates are carried satisfying KRT(Korean Rail Transit) and new KRS(Korean Railway Standards). Based on the results of pilot tests, required structural strength and admixture effects are evaluated. Additionally, typical lightweight aggregates are replaced so that lightweight and strength are improved for serviceability of poor working conditions and proper maintenance in urban train tunnel.

Engineering Characteristics of CLSM with Regard to the Particle Size of Bottom Ash (저회의 입도변화에 따른 CLSM의 공학적특성)

  • Lee, Yongsoo;Kim, Taeyeon;Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.10
    • /
    • pp.5-10
    • /
    • 2020
  • As the demand for the recycling of industrial by-products increases due to various environmental restrictions including the prohibition of ocean disposal, various studies regarding the recycling of industrial by-products are currently being carried out. One of the industrial by-product, coal ash is produced from thermal power generation; studies on the recycling of fly ash have been actively carried out and it is currently recycled in various fields. In the case of bottom ash, however, only a portion of the total amount generated is primarily processed into a particle size of 2~4mm or less than 2mm to be used for gardening purpose and light weight aggregate and so on. The remaining amount is buried at ash disposal sites. Therefore, various studies are needed to develop measures to use bottom ash. This study aimed at identifying the optimal particle size and mixing ratio of bottom ash to be used as CLSM aggregate. To this end, it evaluated the usability of bottom ash as CLSM aggregate, by investigating the flowability and strength change characteristics of CLSM produced with regard to the mixing ratio of weathered granite soil and bottom ash, particle size of bottom ash to be mixed and soil binder addition rate and conducting a heavy metal leaching test.

Evaluation on the Effect of Depth Buried Pipeline and Refilling Materials on Pavement Performance (도로하부 매설관의 매설심도 및 되메우기 재료가 포장체에 미치는 영향 평가)

  • Baek, Cheolmin;Kim, Yeong Min;Kwon, Soo-Ahn;Hwang, Sung Do;Kim, Jin Man
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.105-112
    • /
    • 2013
  • PURPOSES : Compared to the criteria from advanced countries, Korea has conservative criteria for the buried depth of pipeline (about 30~70cm deeper) causing the waste of cost and time. Therefore, this research investigated the effect of various buried depths of pipeline on pavement performance in order to modify the criteria to be safe but economical. In addition, a recycled aggregate which is effective in economical and environmental aspect was evaluated to be used as a refilling material. METHODS : In this study, total 10 pilot sections which are composed with various combinations of pavement structure, buried depth of pipeline, and refilling material were constructed and the telecom cable was utilized as a buried pipeline. During construction, LFWD (Light Falling Weight Deflectometer) tests were conducted on each layer to measure the structural capacity of underlying layers. After the construction is completed, FWD (Falling Weight Deflectometer) tests and moving load tests were performed on top of the asphalt pavement surface. RESULTS : It was found from the LFWD and FWD test results that as the buried depth decrease, the deflections in subbase and surface layer were increased by 30% and 5~10%, respectively, but the deflection in base layer remained the same. In the moving load test, the longitudinal maximum strain was increased by 30% for 120mm of buried depth case and 5% for 100mm of buried depth case. Regarding the effect of refilling material, it was observed that the deflections in subbase and surface layer were 10% lager in recycled aggregate compared to the sand material. CONCLUSIONS : Based on the testing results, it was found that the change in buried depth and refiliing material would not significantly affect the pavement performance. However, it is noted that the final conclusion should be made based on an intensive structural analysis for the pavement under realistic conditions (i.e., repeated loading and environmental loading) along with the field test results.

Freezing and Bearing Capacity Characteristics of Road Foundations under Temperature Condition (온도조건에 의한 도로하부 지반의 동결 및 지지력 특성)

  • Shin, Eun-Chul;Kim, Sung-Hwan;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.5-14
    • /
    • 2012
  • In the current design codes for anti-freezing layer, the thickness of anti-freezing layer is calculated by freezing depth against the temperature condition. Therefore, they have a tendency of over-design and uniform thickness without the considerations of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential for studying the appropriateness and bearing capacity of road foundation materials as well as their seasonal and mechanical properties to take an appropriate and reasonable design of the road structure system. In this paper, the freezing and bearing capacity characteristics of typical road foundation materials were evaluated in the large scale laboratory test. LFWD (light falling weight deflectometer) was used to determine the change of elastic modulus ($E_{LFWD}$) caused by to the frost heave and thaw. Furthermore, the influence of crushed natural aggregate on the freezing of the subgrade soil was studied to verify the function and effectiveness of the anti-freezing layer.