• 제목/요약/키워드: Light-pipe system

검색결과 86건 처리시간 0.02초

하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석 (Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop)

  • 박용철;이용섭;지대영
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

SLD동조 광원과 에탈론 필터를 이용한 FBG 센서 신호처리 시스템 (FBG Sensor Signal Processing System using SLD Tunable Light Source and Etalon Filter)

  • 정철;이호준;김기수
    • 대한전자공학회논문지SD
    • /
    • 제41권3호
    • /
    • pp.39-44
    • /
    • 2004
  • 광섬유 브래그 격자 센서는 광섬유의 코어의 굴절률 변조에 의해서 제작되며, 이 센서는 외부의 스트레인에 따라 브래그 파장이 변화하게 된다. 본 논문에서는 광섬유 브래그 격자 센서를 파장 영역에서 신호처리 할 수 있는 방법에 대하여 연구하였다. SLD와 F-P 필터로 구성된 sweep 반도체 광원과 F P 필터내의 PZT의 히스테리시스 특성을 보상하기 위한 에탈론 필터와 장기 계측을 위해 절대 파장 기준으로 온도 안정된 광섬유 브래그 격자를 사용하였다. 콘크리트 흄관에서 FBG 센서의 스트레인 응답 특성을 전기저항 센서와 비교하였다. 그리고 광섬유 격자 센서를 이용하여 장거리 변위의 측정 가능성을 확인하였다.

Long-Range Guided Wave Inspection of Structures Using the Magnetostrictive Sensor

  • Kwun, He-Geon;Kim, Sang-Young;Light, Glenn M.
    • 비파괴검사학회지
    • /
    • 제21권4호
    • /
    • pp.383-390
    • /
    • 2001
  • Long-range guided wave inspection is a new emerging technology for rapidly and globally inspecting a large area of a structure from a single test location. This paper describes a general overview of the guided wave properties and its application for long-range inspection of structures the principle and instrument system for a guided wave inspection technology called "magnetostrictive sensor (MsS)" that generates and detects guided waves electromagnetically in the material under testing, and examples of long-range guided wave inspection of structures that can be accomplished using the MsS.

  • PDF

일반배관용 스테인리스강관 및 이음쇠의 소화설비 적용 방안 (Measures applied for fire protection system of Light gauge strainesss steel pipe and the fittings for ordinary piping)

  • 남준석;최진종;김영호;박주환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.83-86
    • /
    • 2011
  • 옥내소화전설비, 스프링클러설비 등 수계소화설비에 일반배관용 스테인리스강관과 그 연결에 필요한 이음쇠의 사용가능성을 적용사례, 내식성 등을 통해 확인하였고, 기존 수계소화 설비의 배관에 대한 개선방안을 도출하였다. 일반배관용 스테인리스강관 및 이음쇠는 국내의 경우 수도용으로 활발히 사용되고 있으며, 독일 영국 일본 미국 등의 수계소화설비에 사용되고 있음을 확인할 수 있었다. 강관과 이음쇠의 연결상태에서 내식성을 확인하기 위해 0.5 %와 3.5 %의 소금물을 관내에 주입한 후 28일 보관한 결과 이상이 없음을 확인하였다. 또한, 기존에 설치되어있는 수계소화설비는 배관계의 온도차에 의한 보상방법이 되어있지 않아 작동물질의 열팽창에 따라 강관, 이음쇠의 파손이 발생할 수 있음을 확인하었다.

  • PDF

첨단 태양광채광시스템의 개발현황 및 활용실태 분석에 관한 연구 (An Analysis on Development and Application of Solar Sunlighting Systems)

  • 김정태;황민구;한봉수
    • KIEAE Journal
    • /
    • 제2권1호
    • /
    • pp.63-68
    • /
    • 2002
  • Solar sunlighting systems are useful to apply for most buildings. This study aims to analysis the development and architectural application of solar sunlighting systems. For the purpose, abroad developing situation of solar sunlighting systems were investigated and analyzed literally. And, by case studies, architectural application methods are analyzed. As results, light pipe systems are mainly used for small building and houses. Also solar mirror systems are used for atrium and underground spaces. Lens-fiber systems are applied for high rise buildings and office buildings which internally have no influx of sunlighting. Some application suggestion in our country are discussed.

과급압력, 배압, 분사 시기 및 분사량에 따른 복합 방식 배기 재순환 시스템 적용 디젤 엔진의 최적화에 대한 연구 (Optimization of Diesel Engine Performance with Dual Loop EGR considering Boost Pressure, Back Pressure, Start of Injection and Injection Mass)

  • 박정수;이교승;송순호;전광민
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.136-144
    • /
    • 2010
  • Exhaust gas recirculation (EGR) is an emission control technology allowing significant NOx emission reduction from light-and heavy duty diesel engines. The future EGR type, dual loop EGR, combining features of high pressure loop EGR and low pressure loop EGR, was developed and optimized by using a commercial engine simulation program, GT-POWER. Some variables were selected to control dual loop EGR system such as VGT (Variable Geometry Turbocharger)performance, especially turbo speed, flap valve opening diameter at the exhaust tail pipe, and EGR valve opening diameter. Applying the dual loop EGR system in the light-duty diesel engine might cause some problems, such as decrease of engine performance and increase of brake specific fuel consumption (BSFC). So proper EGR rate (or mass flow) control would be needed because there are trade-offs of two types of the EGR (HPL and LPL) features. In this study, a diesel engine under dual loop EGR system was optimized by using design of experiment (DoE). Some dominant variables were determined which had effects on torque, BSFC, NOx, and EGR rate. As a result, optimization was performed to compensate the torque and BSFC by controlling start of injection (SOI), injection mass and EGR valves, etc.

Urea-SCR 시스템에 의한 소형 디젤엔진의 NOx 저감 특성에 관한 연구 (A Study on the Characteristics of NOx Reduction by Urea-SCR System for a Light-Duty Diesel Engine)

  • 남정길;이돈출;최주열;최재성
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.521-527
    • /
    • 2005
  • The effects of an urae injection at the exhaust pipe for a 4-cylinder DI(Direct Injection) diesel engine are investigated experimentally. The urea quantity was controlled by NOx quantity and MAF(Manifold Air Flow). The urea injection must be precisely metered and then I used the urea syringe pump. I have tested 4 kinds of items that were with the EGR base engine and without the EGR engine. Then I tested each urea-SCR(Selective Catalytic Reduction) system. As the results, I can caculate the SUF(Stoichiometric Urea Flow) and visualize the NOx results by variation of engine speed and engine load. Also, I can make the NOx map. Therfore, I knew that NOx reduction effects of the urea-SCR system without the EGR engine were better than the with EGR base engine except of low load and low speed.

  • PDF

집중변수모델을 이용한 LED조명등 방열기구의 성능분석 (Performance Analysis of Heat Sink for LED Downlight Using Lumped Parameter Model)

  • 김의광;조영철;이승신;안영훈
    • 에너지공학
    • /
    • 제26권2호
    • /
    • pp.64-72
    • /
    • 2017
  • 중동지역 환경에 적합한 70 W급 LED 조명등의 성능분석을 집중변수모델을 이용하여 수행하였다. LED 조명등은 발열기판, 히프파이프, 방열판으로 구성된다. LED 조명등을 4개의 물체로 구분하고, 각각에 대해 에너지평형을 적용하여, 4개의 연립 비선형미분방정식 형태의 집중변수모델을 수립하였다. 연립 방정식의 해는 Runge-Kutta법을 이용하여 구하였다. 집중변수모델의 대류열전달계수는 다차원해석을 통하여 구하였으며, 실험결과와 비교한 결과, 발열기판은 $1.5^{\circ}C$, 상부방열판에서 $1.8^{\circ}C$의 오차를 가지며, 상대오차는 약 0.6 %임을 확인하였다. 이 모델을 이용하여 대기온도가 $55^{\circ}C$인 정상 운전조건, 태양광만 주어질 때의 조건, 태양광이 주어진 상태에서의 비정상 운전조건, 상부방열판이 없는 경우 등에 대한 온도분포분석을 수행하였다.

소듐냉각고속로 원형로 중간열전달계통 고온배관의 파단전누설 예비평가 (Preliminary Leak-before Break Assessment of Intermediate Heat Transport System Hot-Leg of a Prototype Generation IV Sodium-cooled Fast Reactor)

  • 이사용;김낙현;구경회;김성균;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.126-133
    • /
    • 2016
  • Recently, the research and development of Sodium-cooled Fast Reactors (SFRs) have made progresses. However, liquid sodium, the coolant of an SFR, is chemically unstable and sodium fire can be occurred when liquid sodium leaks from sodium pipe. To reduce the damage by the sodium fire, many fire walls and fire extinguishers are needed for SFRs. LBB concept in SFR might reduce the scale of sodium fire and decrease or eliminate fire walls and fire extinguishers. Therefore, LBB concept can contribute to improve economic efficiency and to strengthen defense-in depth safety. The LBB assessment procedure has been well established, and has been used significantly in light water reactors (LWRs). However, an LBB assessment of an SFR is more complicated because SFRs are operated in elevated temperature regions. In such a region, because creep damage may occur in a material, thereby growing defects, an LBB assessment of an SFR should consider elevated temperature effects. The procedure and method for this purpose are provided in RCC-MRx A16, which is a French code. In this study, LBB assessment was performed for PGSFR IHTS hot-leg pipe according to RCC-MRx A16 and the applicability of the code was discussed.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF