• Title/Summary/Keyword: Light reflectance

Search Result 360, Processing Time 0.03 seconds

Fundamental Study on the Quantitative Analysis of Fluorescent Whitening Agent used for Papermaking (제지용 형광증백제의 정량분석에 대한 기초연구)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Hui-Jin;Gwak, Hye-Joeng
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.2
    • /
    • pp.9-15
    • /
    • 2011
  • Fluorescent whitening agent (FWA) is a widely used chemical in paper industry, but a systematic and scientific method on FWA analysis has not been established. We performed the basic researches on the fluorescence analysis of FWA. The fluorescence of FWA was investigated using a spectrofluorometer and a spectrophotometer. When FWA solution was analyzed using the spectrofluorometer, we found that the peak wavelength of the fluorescence emission was about 440 nm and that of the fluorescence excitation was about 370 nm irrespective of FWA types. Papers dyed with an internal FWA were prepared in a laboratory and the reflectance and the fluorescence index were measured using the spectrophotometer. It was confirmed that the optimum peak wavelength of the reflectance was 440 nm and the fluorescence index calculated from the CIE whiteness with and without UV light under a light source D65 was the best indicator to measure the fluorescence of FWAs exiting in papers.

A Wearable Watch-type Reflectance-based Blood-oxygen Saturation (SpO2) Level Estimation (반사광을 이용한 손목시계형 혈중산소포화도 (SpO2) 측정기)

  • Lee, Hooseok;Thap, Tharoeun;Lee, Jinseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.578-579
    • /
    • 2015
  • Transmission and reflectance are two non-invasive techniques to perform pulse oximetry. This paper presents a design of reflectance-based pulse oximetry for watch-type wearable device, in which sensor and detector are located on the same surface of the body part. The basic principle of a pulse oximeter is based on the measurement of the red and infrared (IR) light absorption. Oxygenated blood has significant differences of light absorption characteristics than deoxygenated blood under red (660 nm) and infrared (940 nm) wavelength. Infrared is absorbed more by oxygenated hemoglobin than red. So the hardware implementation is included placing of the two LEDs (red and IR) with single photo-detector in the middle on the patient's wrist to get the corresponding pulsatile signals which are used to estimate the $SpO_2$.

Determination of Germination Quality of Cucumber (Cucumis Sativus) Seed by LED-Induced Hyperspectral Reflectance Imaging

  • Mo, Changyeun;Lim, Jongguk;Lee, Kangjin;Kang, Sukwon;Kim, Moon S.;Kim, Giyoung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.318-326
    • /
    • 2013
  • Purpose: We developed a viability evaluation method for cucumber (Cucumis sativus) seed using hyperspectral reflectance imaging. Methods: Reflectance spectra of cucumber seeds in the 400 to 1000 nm range were collected from hyperspectral reflectance images obtained using blue, green, and red LED illumination. A partial least squares-discriminant analysis (PLS-DA) was developed to predict viable and non-viable seeds. Various ranges of spectra induced by four types of LEDs (Blue, Green, Red, and RGB) were investigated to develop the classification models. Results: PLS-DA models for spectra in the 600 to 700 nm range showed 98.5% discrimination accuracy for both viable and non-viable seeds. Using images based on the PLS-DA model, the discrimination accuracy for viable and non-viable seeds was 100% and 99%, respectively Conclusions: Hyperspectral reflectance images made using LED light can be used to select high quality cucumber seeds.

Reflector Design for LED Pedestrian Lighting Using Indirect Reflectance Type (간접 반사 방식의 LED 보안등기구 반사판 설계)

  • Chae, Sung-Gi;Jung, Dong-Hwan;Lee, Yoon-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.6-13
    • /
    • 2012
  • In this paper, we took an indirect reflectance type that irradiates light from an LED module, which reflects light from a reflector onto the road. This LED pedestrian lighting design produces minimal glare from a relatively simple structure. Using LightTools 7.2, we conducted a study on the varying shape and curvature of the reflector. In order to further investigate this data, we researched the ratio of the DLOR and ULOR, the average illuminance, and the uniformity of the illumination. Based on this research, we selected optimum conditions to realize the actual LED pedestrian lighting using RELUX software. We found the average illuminance value to be 22[1x] and the illuminance uniformity ratio to be 0.23, which met the criteria of the proposed standards set in KS C 7658. In addition, it also satisfied the criteria of the standards set in KS A 3701 by having TI (Threshold Increment) at 7[%].

Recognition of Tabacco Ripeness & Grading based on the Neural Network (신경회로망을 이용한 담배 숙도인식 및 등급판정)

  • LEE, S.S.;LEE, C.H.;LEE, D.W.;HWANG, H.
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.1
    • /
    • pp.5-14
    • /
    • 1995
  • Efficient algorithms for the automatic classification of flue-cured tovacco ripeness and grading have been developed The ripeness of the tobacco was classified into 4 levels vased on the color. The lab-built simple RGB color measuring system was utilized for detecting the light reflectance of the tobacco leaves. The measured data were used far training the artificial neural network The performance of the trained network was also tested far the untrained samples. The spectrophotometer was used to detect the light reflectance and absorption of the graded tobacco leaves in the frequency ranges of the visible light The measured data and the statistical analysis was performed to investigate the light characteristics of the graded samples. The measured data were obtained from samples of 5 different grades directly without considering the leaf positions. Those data were used far training the artificial neural network The performance of the trained network was also tested far the untrained samples. The neural network based sensor information processing showed successful results for grading of tobacco leaves.

  • PDF

The research of anti-reflection coating using porous silicon for crystalline silicon solar cells (다공성 실리콘을 이용한 결정질 실리콘 태양전지 반사방지막에 관한 연구)

  • Lee, Jaedoo;Kim, Minjeong;Lee, Soohong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.90.2-90.2
    • /
    • 2010
  • The crystalline silicon solar cells have been optical losses. but it can be reduced using light trapping by texture structure and anti-reflection coating. The high reflective index of crystalline silicon at solar wavelengths(400nm~1000nm) creates large reflection losses that must be compensated for by applying anti-reflection coating. In this study, the use of porous silicon(PSi) as an active material in a solar cell to take advantage of light trapping and blue-harvesting photoluminescence effect. Porous silicon is form by anodization and can be obtained in an electrolyte with hydrofluoric. We expect our research can results approaching to lower than 10% of several reflectance by porous silicon solar cells.

  • PDF

The Study of Possibility of Finding a Reagent for Cancer Diagnosis by Urine NMR Measurement

  • Kim, Yong-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1986
  • For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

Relationship between Arc Resistance and Light Reflectance of PTFE Composites (PTFE 복합재료의 내아크성과 광반사율)

  • Park, Hoy-Yul;Kang, Dong-Pil;Han, Dong-Hee;Ahn, Myeong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1355-1356
    • /
    • 2001
  • An experimental study on arc resistance and light reflectance of PTFE is presented. PTFE has been used widely as a material for circuit breaker nozzle. In the arcing environment, radiative power incident upon the nozzle wall may be transmitted through the nozzle material. Adding some fillers into PTFE was expected to be efficient in improving the endurability to radiation.

  • PDF

B-spline Volume BRDF Representation and Application in Physically-based Rendering (물리기반 렌더링에서의 비스플라인 볼륨 BRDF 표현과 응용)

  • Lee, Joo-Haeng;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Physically-based rendering is an image synthesis technique based on simulation of physical interactions between light and surface materials. Since generated images are highly photorealistic, physically-based rendering has become an indispensable tool in advanced design visualization for manufacturing and architecture as well as in film VFX and animations. Especially, BRDF (bidirectional reflectance distribution function) is critical in realistic visualization of materials since it models how an incoming light is reflected on the surface in terms of intensity and outgoing angles. In this paper, we introduce techniques to represent BRDF as B-spline volumes and to utilize them in physically-based rendering. We show that B-spline volume BRDF (BVB) representation is suitable for measured BRDFs due to its compact size without quality loss in rendering. Moreover, various CAGD techniques can be applied to B-spline volume BRDFs for further controls such as refinement and blending.

A Dynamic Accuracy Estimation for GPU-based Monte Carlo Simulation in Tissue Optics

  • Cai, Fuhong;Lu, Wen
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.551-555
    • /
    • 2017
  • Tissue optics is a well-established and extensively studied area. In the last decades, Monte Carlo simulation (MCS) has been one of the standard tools for simulation of light propagation in turbid media. The utilization of parallel processing exhibits dramatic increase in the speed of MCS's of photon migration. Some calculations based on MCS can be completed within a few seconds. Since the MCS's have the potential to become a real time calculation method, a dynamic accuracy estimation, which is also known as history by history statistical estimators, is required in the simulation code to automatically terminate the MCS as the results' accuracy achieves a high enough level. In this work, spatial and time-domain GPU-based MCS, adopting the dynamic accuracy estimation, are performed to calculate the light dose/reflectance in homogeneous and heterogeneous tissue media. This dynamic accuracy estimation can effectively derive the statistical error of optical dose/reflectance during the parallel Monte Carlo process.