• 제목/요약/키워드: Light propagation

검색결과 322건 처리시간 0.027초

무질서한 매질에서 침투깊이와 파동 전파 (Penetration depth and Wave Propagation in Random Media)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The influence of fluorophor, scatterer, absorber in turbid materials by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it is studied the molecular property by laser induced fluorescence spectroscopy. It can be found that the effects of optical property are penentrated in scattering media by the optical $parameters({\mu}s$, ${\mu}a$, ${\mu}t$, ${\gamma}$, ${\rho})$. The value of scattering coefficient ${\mu}s$ is large appeared by means of the increasing particles of scattering, it can be found that the slope appears exponentially as a function of distance from laser source to detector. It may also utilize in designing the best model for oil chemistry, laser medicine and application of medical engineering.

Asymbiotic seed germination and in vitro propagation condition in Calanthe discolor Lindl.

  • Kwon, Huyk Joon;Shin, So Lim;Bae, Kee Hwa;Kim, Soo-Young
    • Journal of Species Research
    • /
    • 제6권1호
    • /
    • pp.68-75
    • /
    • 2017
  • We investigated the effects of sodium hypochlorite (NaOCl) and culture medium on embryo swelling and germination of Calanthe discolor Lindl., and established a method for determining the swelling and protocorm formation of C. discolor seeds via in vitro examination of immature seeds. Treatment of immature seeds with NaOCl greatly enhanced the extent of embryo swelling and protocorm formation of immature zygote embryos compared to seeds without NaOCl treatment. The effects of the culture media were also evaluated with regard to embryo swelling and protocorm formation of in vitro cultured seeds with and without NaOCl treatment. Additionally, the effects of white fluorescent light and red and blue LEDs lights on seedling growth in in vitro culture were examined. The most suitable condition for seedling growth after 12 weeks of culture was the red LEDs light with POM medium. These results show effective asymbiotic germination and growth of C. discolor.

신경회로망을 이용한 카메라 교정과 2차원 거리 측정에 관한 연구 (Neural Network Based Camera Calibration and 2-D Range Finding)

  • 정우태;고국원;조형석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.510-514
    • /
    • 1994
  • This paper deals with an application of neural network to camera calibration with wide angle lens and 2-D range finding. Wide angle lens has an advantage of having wide view angles for mobile environment recognition ans robot eye in hand system. But, it has severe radial distortion. Multilayer neural network is used for the calibration of the camera considering lens distortion, and is trained it by error back-propagation method. MLP can map between camera image plane and plane the made by structured light. In experiments, Calibration of camers was executed with calibration chart which was printed by using laser printer with 300 d.p.i. resolution. High distortion lens, COSMICAR 4.2mm, was used to see whether the neural network could effectively calibrate camera distortion. 2-D range of several objects well be measured with laser range finding system composed of camera, frame grabber and laser structured light. The performance of 3-D range finding system was evaluated through experiments and analysis of the results.

  • PDF

꼬리진달래의 造景樹木化를 위한 基礎硏究(III) -繁殖 實驗을 中心으로- (A Study on the Wild Rhododendron Micranthum for Landscape Use)

  • 이병용;이기의;유근창
    • 한국조경학회지
    • /
    • 제18권3호통권39호
    • /
    • pp.137-141
    • /
    • 1990
  • This study was carried out to investigate the propagation methods of the Rhododendron micranthum as a landscape plant The results obtained are as follows : 1. The optimum temperature for seed germination was $20^{\circ}C$, and the seed germination needs light. 2. GA and thiourea did not affect the seed germination under light, but GA gad substitutive effect. 3. 87% and over of germination rates were obtained in room temperature and $5^{\circ}C$ dry storages. 4. The rooting rate was high on sandy loam, vermiculite, and vermiculite 50%+sand 50%, at softwood and hardwood cutting(hardwood ; 45~48%, softwood ; 45~48%). 5. The significant effects on rooting were found with the treatment of NAA 500~2000ppm.

  • PDF

A Dynamic Accuracy Estimation for GPU-based Monte Carlo Simulation in Tissue Optics

  • Cai, Fuhong;Lu, Wen
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.551-555
    • /
    • 2017
  • Tissue optics is a well-established and extensively studied area. In the last decades, Monte Carlo simulation (MCS) has been one of the standard tools for simulation of light propagation in turbid media. The utilization of parallel processing exhibits dramatic increase in the speed of MCS's of photon migration. Some calculations based on MCS can be completed within a few seconds. Since the MCS's have the potential to become a real time calculation method, a dynamic accuracy estimation, which is also known as history by history statistical estimators, is required in the simulation code to automatically terminate the MCS as the results' accuracy achieves a high enough level. In this work, spatial and time-domain GPU-based MCS, adopting the dynamic accuracy estimation, are performed to calculate the light dose/reflectance in homogeneous and heterogeneous tissue media. This dynamic accuracy estimation can effectively derive the statistical error of optical dose/reflectance during the parallel Monte Carlo process.

적외선을 이용한 생체신호의 원격측정에 관한 연구 (A Study on the Biotelemetry using Infra-red Light)

  • 허수진
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권2호
    • /
    • pp.169-175
    • /
    • 1993
  • Recently, interest in infra-red(IR) telemetry has increased because of the entirely different propagation and reflection properties of IR light as compared to radiowaves. IR hardly penetrates most materials and is reflected from obstacles. An biotelemetry system using these characteristics of indirect transmitted IR lights was developed, in which 3 ECG's are multiplexed and modulated in PDM/PIM pulse sequence. This proto-type system enables us to realize the non-restraint measurement of biological signals. Compared with conventional radio telemetry, this technique has some merits such as no electromagnetic interference, no frequency allocation problem, no government control over transmission power.

  • PDF

Optical-Loss Measurement of a Silicon-Slab Waveguide

  • Tresna, Wildan Panji;Putra, Alexander William Setiawan;Maruyama, Takeo
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.551-557
    • /
    • 2020
  • A mirror-in-slab waveguide is fabricated on a slab waveguide by using the refractive-index contrast between two materials, with the reflection performance depending on the slab waveguide's design. In this research, a slab waveguide design consisting of silicon (Si) as the core and SiO2 as the substrate was designed and developed to determine the coupling, waveguide, and mirror losses. Based on experimental results, coupling loss is dominant and is affected by the design of the slab waveguide. Furthermore, the mirror loss is affected by the design of the mirror, such as the curvature radius and the size of the mirror. TE and TM polarizations of light are used in the measurements. The experimental results show that mirror losses due to reflection by mirrors are 0.011 dB/mirror and 0.007 dB/mirror for TE and TM polarizations respectively. A simulation was performed to confirm whether the size of mirror is sufficient to reflect the input light, and to check the quality of the surfaces of fabricated mirrors.

Monte Csrlo 시뮬레이션을 이용한 생체조직내의 광선량 측정 (Measuring the Light Dosimetry Within Biological Tissue Using Monte Carlo Simulation)

  • 임현수;구철희
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.199-204
    • /
    • 1999
  • 생체조직내의 정확한 광선량 측정이 PDT 치료의 효과에 중요한 영향을 주므로 본 연구에서는 광선량 측정을 위해서 Monte Carlo 시뮬레이션을 이용하였다. 실험에 사용한 계수는 실제 생체조직의 광학계수이고 위상함수는 Henyey-Greenstein 위상함수를 사용하였다. 결과는 깊이에 따른 Fluency rate의 변화로 나타내었으며 기존 이론과의 차이는 0.35%에 지나지 않았다. 실험에 사용한 생체조직은 인체조직, 돼지조직, 쥐간조직, 토기근육조직이다. 대부분의 생체조직은 가시광선영역에서 큰 산란계수를 가지고 있으며 이것은 투과도에 큰 영향을 미치는 것으로 밝혀졌다. 가시광선 영역에서 인체조직의 투과 깊이는 1.5~2cm이었다. Monte Carlo 시뮬레이션을 이용하여 생체조직내의 광전파(light propagation), 광선량(light dosimetry), 에너지율(fluence rate), 투과깊이(penetration depth)를 효과적으로 측정할 수 있음을 보여주었다.

  • PDF

Ferritin Light Heavy Chain 유전자가 도입된 인삼형질전환체의 단일배발생을 통한 식물체의 기내증식 (In vitro Propagation of Transgenic Ginsengs Introduced with Ferritin Light Heavy Chain Gene through Single Embryo Culture)

  • 윤영상;김종학;김무성;양덕춘
    • 한국자원식물학회지
    • /
    • 제17권2호
    • /
    • pp.161-168
    • /
    • 2004
  • Ferritin light heavy chain (FLHC) gene는 일부 중금속과 결합, 저장 및 운반하여 무독화 시킬 수 있는 것으로 알려져 있다. Fe 관련 유전자인 FLHC유전자를 식물 발현용 promoter인 35S promoter와 Tnos를 사용하여 식물 형질전환용 vector를 재조합하였다. 식물세포형질전환용 binary vector는 상기 cassette vector가 조립이 매우 양호하며 border sequence를 가지고 있는 pRD400 binary vector를 사용하여 최종적으로 가나마이신 내성 유전자 (NPT II gene)와 tadpole ferritin heavy chain gene 및 human ferritin light chain gene를 함유하고 있는 binary vector를 재조합하였다. Binary vector의 아그로박테리움에 도입은 triparental mating 방법에 의하여 수행하여 AB배지 및 가나마이신 함유 배지에서 disarmed Ti-vector를 가지고 있는 Agrobacterium tumefaciens MP90/FLHC을 선발하였다. FLHC 유전자 도입된 식물형질전환용 binary vector를 이용하여 형질전환방법을 변형하여 많은 embryo를 유도하였으며 유도된 embryo들은 GA 10mg/L가 첨가된 배지에 지상부를 유도하였다. 형질전환체식물체의 정상적인 생장을 유도하기 위해 최적의 배양조건을 조사하였던 바, 비교적 1/3 MS배지에서 뿌리의 생장과 지상부의 생장이 균일하게 생장하는 경향을 보였으며, 뿌리와 줄기가 잘 발달된 약 7cm의 유식물체를 대량으로 증식하여, 모래와 흙이 1:1로 혼합된 토양에 옮겼다.

경량 델타로봇의 모델링 및 모션 제어 (Modeling and Motion-control for a Light-weight Delta Robot)

  • 김성일;홍준호;신동원
    • 한국기계가공학회지
    • /
    • 제17권3호
    • /
    • pp.155-162
    • /
    • 2018
  • Delta robots are usually used for industrial manufacturing, but heavy weight and expensive price have been obstacles to rapid propagation of robots in the field. The goal of this research is to make light-weight and price-competitive delta robots. To reduce the weight, we used plastic material for the arm link, and to reduce the price, we used a step-motor as the main actuator. First we formulated the equations of inverse kinematics for the designed delta robot and then verified these equations by using multibody-dynamics simulation. An algorithm of motion control was developed and applied to the motion-processing unit using a timer-interrupt of 8 milliseconds. Finally, we tested the performance of the new delta robot by checking its control of motion along line segments.