• Title/Summary/Keyword: Light path

Search Result 340, Processing Time 0.031 seconds

Basic Experimental Study on Room Lighting Effects using Artificial Light Source (인공 광원을 이용한 실내 조명 효과에 대한 기초 실험 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • This study is performed to investigate the effect of the artificial light for room lightening. To do that, the experiments were done using the black room with 1m3 and performed to show the effect of the length between the room and light source and light intensities as LUX. The LUX of 18 sites in the room was measured using LUX meter. The length between the room and the light source was chosen as 500mm, 1000mm, and 1500mm and the light intensities was 3 levels. The results were shown the distinct difference between the part directly projected through the light path and non-directly projected. So, the light delivery path have to be modified for next step research. The results were very sensitive for the part directly projected through the light path. This study showed the basic results for room lightening using light source to simulate the solar lightening and was worth in a strict sense as fundamental study.

  • PDF

A Study on Optical Properties in Biological Tissue Using A Photon Path Diffusion Model (광 항적경로 모델을 이용한 피하조직에서의 광 특성에 관한 연구)

  • 임현수
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.265-274
    • /
    • 1994
  • This paper proposes a method of noninvasive reflectance light to measure the blood fractional volume (Vb) and oxygen saturation ($SO_2$) of biological tissue. We chose the red light of 660nm and infrared light of 880nm. In Vivo reflectance data were obtained by the physiological changes front the surface of the skin over the calf in human subject. The reflected light intensity from different layers within a biological tissue was measured by specially designed reflectometer to apply photon path diffusion model. The collected data represent the changes of blood (ractional volume and oxygen saturation at each reflected light wavelengths. The data evaluation was assessed by examining the slopes of the plotted indices for the changes in oxygen saturation and blood (ractional volume. The results presented in this paper claim that light reflectance can separately discriminate the change of blood volume and that of oxygenation in muscle and also in skin.

  • PDF

Effects of the Classes on the Path of the Light through the Lens Focused on Substantial Concepts for the Elementary School Gifted in Science (렌즈를 지나는 빛의 경로 학습에서 기본 개념을 강화한 초등 과학 영재 수업의 효과)

  • Lee, In-Ho;Hong, Jun-Euy;Jhun, Young-Seok
    • Journal of Korean Elementary Science Education
    • /
    • v.25 no.spc5
    • /
    • pp.548-555
    • /
    • 2007
  • In this paper, we suggested that those elementary school students who are gifted in science should be taught basic and fundamental concepts to solve applied problems. We developed a teaching model based on a lesson regarding the path that light takes when passing through a lens on the base of refraction of light. We applied the teaching model to scientifically-gifted elementary school students and analyzed the results. The teaching model is based on the circulation loaming model appropriate for learning such concepts. The problems were designed and applied in order to determine the students' level of concept skills held and also to develop new teaching tools to help their understanding of concepts. As a result, we confirmed that the students, who were unable to describe the path of the light before the course of instruction was given, were able to draw and explain the path of light passing trough lens by using the law of refraction following the instruction.

  • PDF

Absolute Positioning System of Mobile Robot using Light Navigation Path (광궤도를 이용한 이동로봇의 절대위치 보정 시스템)

  • 박용택;정효용;국금환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.141-147
    • /
    • 2003
  • This paper represents an absolute positioning system using a light navigation path for mobile robot. The absolute positioning system is composed of the projector unit which generates a laser beam using laser diode and mobile robot with the optical detector which has some optical sensors. The projector unit is fixed over the navigating plane of mobile robot to generate the light navigation path, and the optical detector located upper part of mobile robot detects the generated laser beam from the projector. The navigation of mobile robot is controlled by the micro-processor which compares the detected present position from the detector with the previously programmed navigation path. And experimental results show that our sensor system can be used for the absolute positioning system of the mobile robot.

Experimental Study on Performances and Economic Evaluations of the Qualify of the Material for Light Path (광도파로(光導波路)를 위한 재질의 성능과 경제적 평가를 위한 실험적 연구)

  • Pak, Ee-Tong;Lee, Kang-Ju;Park, Hae-Sung
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.175-179
    • /
    • 2007
  • This experimental demonstration has successfully shown that it is possible to use direct sunlight for the illumination of deeper building zones using the material for light path system(light duct). Three kinds of reflectors which were 95% Silver vaporizing fixed, 85% Anodized and 85% Hot melted applied to evaluate and compare their performances each others. Also, these three kind of reflectors were compared in view point of economics. The most high performance was obtained in 95% Silver vaporizing fixed reflector hater than another reflectors of 85% Anodized reflector and 85% Hot melted reflector even though more high production cost in 95% Silver vaporizing fixed reflector. The rest two reflectors of 85% Anodized and 85% Hot melted $10{sim}15%$ less performance than 95% Silver vaporizing fixed reflector but their production cost were low than the production cost of 95% Silver vaporizing fixed reflector which identified very weak and light yellow color in the light.

Exploration of a Light Shelf System for Multi-Layered Vegetable Cultivation (자연광 다층 작물재배를 위한 광선반 시스템에 관한 연구)

  • Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.61-66
    • /
    • 2013
  • This study is to eliminate the need for conventional high density plant factory's artificial light source such as LED to reduce the initial investment of the light source installation as well as the operation cost. Use of solar light could enhance the quality of the vegetables similar to those grown in the natural environment. Provision of solar light into the multilayer vegetable cultivation facilities and collecting maximum and sustainable sunlight without too much loss by tracing solar path and properly distributing it through careful control during daytime are crucial for realizing the investigated rooftop light shelf system for multi-layered vegetable cultivation. In this study, we developed an innovative way of effectively allocating sunlight inside even to otherwise shaded zone of a multi-layer vegetable cultivation facility. To prove the effectiveness of the system's sunlight collection and distribution capability, both simulation and experiment in Daejeon are performed and the outcome is analyzed.

Performance Analysis of Optical Path Difference on Visible Light Communication System for Intelligent Transport Systems

  • Choi, Jae-Hyuck;Lee, Kye-San;Cha, Jae-Sang;Kim, Jin-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.114-120
    • /
    • 2009
  • In outdoor visible light communication channels and LED road illumination communications for the intelligent transport systems (ITS), inter symbol interference (ISI) due to multipath propagation prevents high data rate transmission. Indoor wireless optical communication systems utilizing white LED lights and on the road illumination have been studying about it. Generally, plural lights are installed in room and considered to the traffic information system using existing LED traffic lights. Therefore, their optical path difference must be considered. In this paper, the influence of an optical path difference has been investigated and two approaches against this problem are introduced. One uses on-off keying, return-to-zero (OOK-RZ) coding and the other uses optical orthogonal frequency division multiplexing(OFDM).

  • PDF

A hybrid model of regional path loss of wireless signals through the wall

  • Xi, Guangyong;Lin, Shizhen;Zou, Dongyao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.9
    • /
    • pp.3194-3210
    • /
    • 2022
  • Wall obstruction is the main factor leading to the non-line of sight (NLoS) error of indoor localization based on received signal strength indicator (RSSI). Modeling and correcting the path loss of the signals through the wall will improve the accuracy of RSSI localization. Based on electromagnetic wave propagation theory, the reflection and transmission process of wireless signals propagation through the wall is analyzed. The path loss of signals through wall is deduced based on power loss and RSSI definition, and the theoretical model of path loss of signals through wall is proposed. In view of electromagnetic characteristic parameters of the theoretical model usually cannot be accurately obtained, the statistical model of NLoS error caused by the signals through the wall is presented based on the log-distance path loss model to solve the parameters. Combining the statistical model and theoretical model, a hybrid model of path loss of signals through wall is proposed. Based on the empirical values of electromagnetic characteristic parameters of the concrete wall, the effect of each electromagnetic characteristic parameters on path loss is analyzed, and the theoretical model of regional path loss of signals through the wall is established. The statistical model and hybrid model of regional path loss of signals through wall are established by RSSI observation experiments, respectively. The hybrid model can solve the problem of path loss when the material of wall is unknown. The results show that the hybrid model can better express the actual trend of the regional path loss and maintain the pass loss continuity of adjacent areas. The validity of the hybrid model is verified by inverse computation of the RSSI of the extended region, and the calculated RSSI is basically consistent with the measured RSSI. The hybrid model can be used to forecast regional path loss of signals through the wall.

Study of Propagation of Light along an Acupuncture Meridian

  • Choi, Chun-Ho;Soh, Kwang-Sup;Lee, Sang-Min;Yoon Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.245-248
    • /
    • 2003
  • Propagation of light along a pericardium meridian is measured and compared with that along a non-meridian path one cm away from the meridian. Source-light is illuminated on the Nei-Guan(PC6) and propagated light is detected at three points along the meridian. Four reference points are one cm away from the corresponding meridian points, respectively. Light propagates better along the meridian than the reference path with more than twenty percent difference for all the subjects tested.

Improvement of Field Calibration of a Transmissometer for Visibility Measurement

  • Kim Kyung W.;Kim Young J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.49-56
    • /
    • 2005
  • A long-path transmissometer is one of the optical instruments widely used to measure atmospheric light extinction coefficient without enclosing a light beam and perturbing aerosols. Over the past two decades, a number of measurements have been carried out using the long-path transmissometer manufactured by OPTEC, Inc. Calibration of the transmissometer should be performed when any component of the transmissometer system is interchanged or installation condition is changed. For a better calibration of the transmissometer, application of a modified calibration method for the existing neutral density (ND)-filter method was recommended for the computation of the atmospheric transmittance using model MODTRAN 4 in this study. It was revealed that the measured light extinction coefficient from the transmissometer which was calibrated using the existing ND-filter method could be overestimated due to the assumption of the atmospheric transmittance suggested by OPTEC, Inc. The uncertainty of the measured light extinction coefficient from the transmissometer calibrated based on the modified ND-filter method was calculated to be approximately $13Mm^{-1}$.