• Title/Summary/Keyword: Light loads

Search Result 244, Processing Time 0.024 seconds

Comparative study on the effect of cooling & heating loads by lighting energy of various light sources in an office building

  • Hong, Won Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.94-105
    • /
    • 2016
  • The objective of the work was to evaluate the impact of lighting energy to cooling and heating consumption in medium scale office building, when currently installed fluorescent lights were replaced with various LED lighting fixtures. This evaluation comes from an integrated approach combining the proper indoor lighting environment and the thermal aspects of cooling & heating consumption in office building. These simulations were performed by coupling an appropriate luminaire analysis for energy consumption and a dynamic thermal simulation software (TRNSYS). To analyze comparative study of effects on the heating, cooling loads, and energy consumption of an LED lamp application, 2 types of LED lamp with low light power watt(LPW) 24W and high LPW 7.5W and a fluorescent lights(FL) with 37W are used respectively. Integrated building energy consumption decreased up to 3.2% when fluorescent lamps were replaced with LEDs. Thus, the high LPW of LED(7.5W) replaced with the same number of FL shows an effective energy saving and cost- effective luminary.

Optimized Operation of Dual-Active-Bridge DC-DC Converters in the Soft-Switching Area with Triple-Phase-Shift Control at Light Loads

  • Jiang, Li;Sun, Yao;Su, Mei;Wang, Hui;Dan, Hanbing
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.45-55
    • /
    • 2018
  • It is usually difficult for dual-active-bridge (DAB) dc-dc converters to operate efficiently at light loads. This paper presents an in-depth analysis of a DAB with triple-phase-shift (TPS) control under the light load condition to overcome this problem. A kind of operating mode which is suitable for light load operation is analyzed in this paper. First, an analysis of the zero-voltage-switching (ZVS) constraints for the DAB converter has been carried out and a reasonable dead-band setting method has been proposed. Secondly, the basic operating characteristics of the converter are analyzed. Third, under the condition of satisfying the ZVS constraints, both the reactive power and the root mean square (RMS) value of the current are simultaneously minimized and a particle swarm optimization (PSO) algorithm is employed to analyze and solve this optimization problem. Lastly, both simulations and experiments are carried out to verify the effectiveness of the proposed method. The experimental results show that the converter can effectively achieve ZVS and improved efficiency.

Evaluation of mental and physical load using inverse regression on sinus arrhythmia scores

  • Lee, Dhong-H.;Park, Kyung-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.3-8
    • /
    • 1987
  • This paper develops a statistical mode which estimates mental and physical loads of light work from sinus arrhythmia (SA) scores. During experiments, various levels of mental and physical loads (respectively scored by information processing and finger tapping rates) were imposed on subjects and SA scores were measured from the subjects. Two methods were used in developing workload estimation model. One is an algebraic inverse function of a multivariate regression equation, where mental and physical loads are independent variables and SA scores are dependent variables. The other is a statistical multivariate inverse regression. Of the two methods, inverse function resulted in larger mean squqre error in predicting mental and physical loads. Hence, inverse regression model is recommended for precise workload estimation.

  • PDF

Analysis of light-frame, low-rise buildings under simulated lateral wind loads

  • Fischer, C.;Kasal, B.
    • Wind and Structures
    • /
    • v.12 no.2
    • /
    • pp.89-101
    • /
    • 2009
  • The Monte Carlo procedure was used to simulate wind load effects on a light-frame low-rise structure of irregular shape and a main wind force resisting system. Two analytical models were studied: rigid-beam and rigid-plate models. The models assumed that roof diaphragms were rigid beam or rigid plate and shear walls controlled system behavior and failure. The parameters defining wall stiffness, including imperfections, were random and included wall stiffness, wall capacity and yield displacements. The effect of openings was included in the simulation via a set of discrete multipliers with uniform distribution. One and two-story buildings were analyzed and the models can be expanded into multiple-floor structures provided that the assumptions made in this paper are not violated.

Change of Stiffness and Impact-Resistance of Flush Door Depending on Core Composition (플러쉬문의 심재구성에 따른 강성도 및 내충격성의 변화)

  • 장상식
    • Journal of the Korea Furniture Society
    • /
    • v.12 no.1
    • /
    • pp.39-45
    • /
    • 2001
  • This study was carried out to evaluate the feasibility of using HDF as surface panels as well as core materials for flush door manufacturing. Several core compositions were developed and applied to manufacture door specimens. Core materials were tested under bending load, door manufacturing process was analysed to find better way of using HDF for door manufacturing, and door specimens were tested under bending, twisting and impact loads. From this study, it was concluded that HDF can be used to manufacture quality flush doors. And it was desirable to use light color HDF as surface panels because dark color HDF caused a problem in manufacturing process by shadow shown through finishing veneer. HDF doors were light, and showed good quality and higher resistance against bending twisting and impact loads.

  • PDF

The Structural Analysis and Experimental Verification for Aluminum Light Railway Vehicle (알루미늄 경전철 차체의 해석 및 시험 평가)

  • Park, Kyoumg-Chang;Jeong, Ji-Ho;Lee, Jahng-Wook;Park, Geun-Soo;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.430-435
    • /
    • 2008
  • Hyundai-Rotem Company has designed and manufactured Light Railway Vehicle (LRV) according to the Urban Rail Transit Code, which applies to urban railway vehicles in Korea. The Urban Rail Transit Code specifies the loads, for which vehicle bodies shall be capable of withstanding, identifies how material data shall be used and presents the principles to be used for design verification by analysis and test. The structural design of railway vehicle bodies depends on the loads they are subjected to and the characteristics of the materials they are manufactured from. Therefore Hyundai-Rotem Company has carried out Finite Element Analysis (FEA) and has performed load tests on the vehicle body according to the Urban Rail Transit Code. This research contains the results obtained by the analysis and the load tests. The analysis was carried out using I-DEAS Master Series 12 and load test were carried out using specially designed test jigs and equipment are used for the load tests.

  • PDF

Daylighting Performance of Topside Lighting Systems for Different Orientations (방위에 따른 정측창 시스템의 채광성능 평가)

  • Kong, Hyo-Joo;Lee, Jin-Seoung;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • Daylighting is core of sustainable design in most buildings. Well-designed daylighting systems can significantly reduce or even eliminate the electric lighting loads during the day time, including air conditioning energy loads. Among window systems. the topside lights systems including monitor lighting, sawtooth lighting, sunscoop and, lightscoop is one of the most popular apparatus to improve the lighting quantity. Also they are important both in terms of energy savings and visual quality. The objective of this study is to analyse daylighting performance of topside lighting system for different orientations. Four types of topside lighting system were tested and comparpd: monitor lighting, sawtooth lighting, lightscoop and sunscoop. Totally 25 measuring points of illuminance on the horizontal plane were monitored from 09:00 to 17:00 on October 6, 2008. Agilent data logger and photometric sensors Li-cor were used. Comparisons with a light factor is discussed. The results found in this study would mean that there were no significant differences in light factor between three cases.

Structural Design of Box Beam Header

  • Jang, Sang-Sik;Park, Young-Ran;Kim, Yun-Hui
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.4
    • /
    • pp.287-295
    • /
    • 2007
  • To obtain a design data for box beams used as headers in light-frame timber construction, $2{\times}6\;(38{\times}140mm),\;2{\times}8\;(38{\times}184mm),\;2{\times}10\;(38{\times}235mm)\;and\;2{\times}12\;(38{\times}286mm)$ members were built as box beam specimens for bending tests. The allowable bending stresses for box beams were obtained through bending tests of these specimens, and span tables were calculated for various loading conditions based on the allowable bending stresses obtained. The allowable bending stresses were determined as the bending stresses at 10mm deflection of specimens from the results of bending tests of box beam specimens. Span tables for box beams were obtained assuming five loading conditions for headers used in exterior walls and two loading conditions for headers used in interior walls. Among these 7 loading conditions, 5 loading conditions applied to headers in exterior walls included the dead loads, the live loads and the snow loads and 2 loading conditions applied to headers in interior walls included the dead loads and the live loads.

  • PDF

Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

Estimation for Primary Tunnel Lining Loads

  • Kim, Hak-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1998.05a
    • /
    • pp.153-204
    • /
    • 1998
  • Prediction of lining loads due to tunnelling is one of the major issues to be addressed in the design of a tunnel. The objective of this study is to investigate rational and realistic design loads on tunnel linings. factors influencing the lining load are summarized and discussed. The instruments for measuring the lining loads are reviewed and discussed because field measurements are often necessary to verify the design methods. Tunnel construction in the City of Edmonton has been very active for storm and sanitary purposes. Since the early 1970's, the city has also been developing an underground Light Rail Transit system. The load measurements obtained from these tunnels are compared with the results from the existing design methods. However, none of the existing methods are totally satisfactory, Therefore, there is some room for improvement in the prediction of lining loads. The convergence-confinement method is reviewed and applied to a case history of a tunnel in Edmonton. The convergence curves are obtained from 2-D finite element analyses using three different material models and theoretical equations. The limitation of the convergence-confinement method is discussed by comparing these curves with the field measurements. Three-dimensional finite element analyses are performed to gain a better understanding of stress and displacement behaviour near the tunnel face. An improved design method is proposed based on the review of existing design methods and the performance of numerical analyses. A specific method or combination of two different methods is suggested for the estimation of lining loads for different conditions of tunnelling. A method to determine the stress reduction factor is described. Typical values of dimensionless load factors nD/H for tunnels in Edmonton are obtained from parametric analyses. Finally, the loads calculated using the proposed method are compared with field measurements collected from various tunnels in terms of soil types and construction methods to verify the method. The proposed method gives a reasonable approximation of the lining loads. The proposed method is recommended as an approximate guideline for the design of tunnels, but the results should be confirmed by field measurements due to the uncertainties of the ground and lining properties and the construction procedures, This is the reason that in-situ monitoring should be an integral part of the design procedure.

  • PDF