• 제목/요약/키워드: Light load operation

검색결과 112건 처리시간 0.023초

Novel Control Range Compensation Method in Power Factor Correction Circuit

  • Park, Youngbae;Cho, Donghye
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.224-225
    • /
    • 2012
  • When Power Factor Correction(PFC) boost converter is designed for the universal input range, unwanted burst operation can be found at high line and light load. This operation may cause an audible noise from the boost inductor or sensitive flicker for human eye can be found in case of the display application. In order to solve this difficulty, this paper proposes the new control range compensation method and shows the effectiveness than the conventional method thru the experimental result.

  • PDF

비대칭 Groove를 이용한 FDB 회전축의 기울기 보상 (Compensation of Inclined Rotating Axis Using Unsymmetric Groove Patterns)

  • 이남훈;한재혁;오동호;김철순;변용규;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.582-585
    • /
    • 2004
  • Most of hard disk drives currently employ fluid dynamic bearing (FDB) for their rotor support. Stiffness of the FDB is affected by many design factors such as bearing clearance, fluid viscosity, and rotational speed. For the high rotating speed HDDs stiffness of the rotor is normally high enough to accomodate load disturbances. However small form factor HDDs that are to be operated in low power consumption are often designed with low stiffness rotors. Although the low stiffness rotor clearly benefits low power operation, it could damage the entire motor structure or head disk interface even by a light mechanical load disturbance such as shock or vibration. In addition, since a single channel HDD does not provide gram load equilibrium in axial direction the rotor could be tilted and make a hard contact to stator. A non-symmetric groove pattern could successfully compensate the tilted rotor angle during operation.

  • PDF

철도 노반의 지지력 평가를 위한 현장 시험법 적용성 연구 (Application of in-situ testing Methods for Bearing Capacity Estimation of Railroad Roadbed)

  • 박창우;최찬용;이일화;김대상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.866-875
    • /
    • 2006
  • The field plate load test a good potential for determining modulus since it measures both plate pressure and settlement. However, because The field plate load test is expensive and takes plenty of time for operation, it is very difficult to figure out the test characteristics of railroad roadbed in detail. For faster and economical operation, the Dynamic Cone Penetrometer(DCP) and the Light Falling Weight Deflectometer(LFWD) have been utilized for estimating the bearing capacity of railroad roadbed. The objective of this study is to determine the relationship between the test(PLT, DCP, LFWD) of the railroad roadbed in Korea. The DCP test and LFWD test for evauluating the strength of railroad roadbed materials produced in Korea are presented in this paper.

  • PDF

Analysis, Design, and Implementation of a Soft-Switched Active-Clamped Forward Converter with a Current-Doubler Rectifier

  • Jang, Paul;Kim, Hye-Jin;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.894-904
    • /
    • 2016
  • This study examines the zero-voltage switching (ZVS) operation of an active-clamped forward converter (ACFC) with a current-doubler rectifier (CDR). The ZVS condition can be obtained with a much smaller leakage inductance compared to that of a conventional ACFC. Due to the significantly reduced leakage inductance, the design is optimized and the circulating loss is reduced. The operation of the ACFC with a CDR is analyzed, and a detailed ZVS analysis is conducted on the basis of a steady-state analysis. From the results, a design consideration for ZVS improvement is presented. Loss analyses of the converters shows that enhanced soft-switching contributes to an efficiency improvement under light-load condition. Experimental results from a 100-W (5-V/20-A) prototype verify that the ACFC with a CDR can attain ZVS across an extended load range of loads and achieve a higher efficiency than conventional ACFCs.

A New High Efficiency Half Bridge Converter with Improved ZVS Performance

  • Lee Sung-Sae;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.187-194
    • /
    • 2006
  • A new asymmetrical pulse width modulation (PWM) half bridge converter with improved ZVS performance is proposed. The ZVS operation of the proposed converter can be maintained from no load to full load conditions since the magnetizing current of the transformer contributes to the ZVS operation at light loads without considerable conduction loss of the transformer and switch. Synchronous rectification is employed to reduce the rectification loss. Operational principles, large signal modeling, ZVS analysis and design equations are presented. Experimental results demonstrate that the proposed converter can achieve a large ZVS range and significant improvement in efficiency for a 100W (5V, 20A) prototype converter.

가솔린 균일 예혼합 압축 착화 디젤기관의 연소 및 배기 특성에 미치는 운전조건의 영향 (Effect of Operation Condition on the Characteristics of Combustion and Exhaust Emissions in a Gasoline Fueled HCCI Diesel Engine)

  • 이창식;김명윤;황석준;김대식
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.48-54
    • /
    • 2004
  • The purpose of this work is to investigate the effect of premixing condition on the combustion and exhaust emission characteristics in a HCCI diesel engine. To from homogeneous charge before intake manifold, the premixed gasoline fuel is injected into a premixed tank by fuel injection system and the premixed gasoline fuel is ignited by direct injected diesel fuel. Experimental result shows the NOx and soot emissions are decreased linearly with the increase of premixed ratio. In the case of intake air temperature $20^{\circ}C$ with light load, the specific fuel consumptions are increased with the rise of premixed ratio and HC and CO emissions are also increased. But the intake air heating can improve the specific fuel consumption at light load condition because increased air temperature promotes the combustion of premixed mixture. In the case of high intake air temperature with high load condition, premixed fuel is auto-ignited before diesel combustion and soot emission is increased.

전압형 인버터로 구동되는 유도기의 안정화 제어 (The Stablized Control Method for The Voltage Source Inverter Fed Induction Motor Driver)

  • 노성채;이현우;이오걸;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.567-570
    • /
    • 1989
  • A constant V/F control system of voltage contrlled PWM inverter has a unstable operation of the low- speed and the light-load. In this paper, the authors propose stability control with idealized operation of induction motor by the neglect of primary leakage inductance and resistance. Also ldealized operation system is adopted voltage error, feed back impedance circuit, and increasing resistance from dead time of switching is compensated by the soft ware with u-processors. The proposed simulation of the idealized control method is proved at the low-speed operation for three phase induction motor.

  • PDF

분산모듈형 태양광 전력조절기의 독립운전 제어 (Control Method of Distributed-Module Type Photovoltaic Power Conditioners under Stand-alone Operation)

  • 서정원;박종후;김혜림
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.448-457
    • /
    • 2013
  • This paper proposes a control method under stand-alone operating mode for distributed-module type photovoltaic power conditioners. In conventional schemes, there are some problems of a controller saturation in the DC-link (or load) voltage controller when overly-heavy load, light load, and the generated PV power reduction occurs, as well as when a transition occurs from an overly-loaded to normal conditions. To overcome these problems, the proposed controller method switches the main control target from DC-link voltage to the maximum power point, which is closer to the stable operating point when it returns to normal operating conditions. For the analysis, a state-plane trajectory was given and the circuit analysis by PSIM simulation was done. For the verification, a prototype hardware with 110[W] and 50[W] dual photovoltaic modules has been implemented. From the results, it can be seen that PV power tracking is successfully done with the proposed method even under a stand-alone operation mode.

이질형 분산시스템에서의 동적 부하재분배를 위한 유전적 접근법 (A Genetic Approach for Dynamic Load Redistribution in Heterogeneous Distributed Systems)

  • 이성훈;한군희
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 부하재분배 방법은 컴퓨터시스템에서 중요한 요소이다. 수신자 개시 부하재분배 알고리즘에서는 전체시스템이 저부하일 때 수신자(저부하 프로세서)가 부하를 이전받기 위해 송신자(과부하 프로세서)를 발견할 때까지 불필요한 이전 요청 메시지를 계속 보내게 된다. 따라서 이같은 상황에서는 과부하 상태인 송신자 프로세서로부터 승인 메시지를 받기까지 불필요한 프로세서간 통신으로 인하여 프로세서의 이용률이 저하되고, 타스크 처리율이 낮아지는 문제점이 발생한다. 본 논문에서는 이질형 분산 시스템에서의 동적 부하재분배를 위해 유전 알고리즘을 기반으로 하는 접근 방법을 제안한다. 이 기법에서는 불필요한 요청메시지를 줄이기 위해 요청 메시지가 전송될 프로세서들이 제안된 유전 알고리즘에 의해 결정된다.

  • PDF

위상제어 LCL형 직렬공진 콘버터의 설계에 관한 연구 (Design considerations for LCL type series resonant converter with phase shift control)

  • 민경진;유상봉;현동석
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.517-525
    • /
    • 1996
  • A Simple AC complex circuit analysis for LCL type series resonant converter with phase shift control is proposed. Based on these analyses, a set of characteristic curves which allows a optimal design procedure for this converter is shown, without increasing the volt-ampere rating of tank circuit Especially, inverter output peak current can be minimized in both full load and partial load conditions. The presented design considerations can make the load range wide from full loads to light loads achieving turn-on with zero voltage switching (ZVS) operation. The detailed analysis and experimental results show the effectiveness of the proposed design algorithms. (author). refs., figs., tab.

  • PDF