• 제목/요약/키워드: Light filter

검색결과 603건 처리시간 0.022초

Wiener 필터링에 기반하는 센서 패턴 노이즈를 활용한 영상 장치 식별 기술 연구 (Imaging Device Identification using Sensor Pattern Noise Based on Wiener Filtering)

  • 이해연
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2153-2158
    • /
    • 2016
  • Multimedia such as image, audio, and video is easy to create and distribute with the advance of IT. Since novice uses them for illegal purposes, multimedia forensics are required to protect contents and block illegal usage. This paper presents a multimedia forensic algorithm for video to identify the device used for acquiring unknown video files. First, the way to calculate a sensor pattern noise using Wiener filter (W-SPN) is presented, which comes from the imperfection of photon detectors against light. Then, the way to identify the device is explained after estimating W-SPNs from the reference device and the unknown video. For the experiment, 30 devices including DSLR, compact camera, smartphone, and camcorder are tested and analyzed quantitatively. Based on the results, the presented algorithm can achieve the 96.0% identification accuracy.

웨이브렛 변환과 편광 필터를 이용한 차량번호판 축출 (Vehicle Plate Extraction Using Wavelet Transform and Polarized Light Filter)

  • 김옥규;이창윤;황형덕;강혜진;박영식
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2003년도 하계학술대회 논문집
    • /
    • pp.102-105
    • /
    • 2003
  • Up to the present studies of the car number recognition system, it is generally known to have serious problems such as relatively long processing time due to the excessive length of data extracted from the number plate based on the current image characteristics, and the image blurring with the physical damage of the brightness and darkness signals of the number plate caused by external impulses with many difficulties in the extraction of the highlighted numbers. In this Paper we used the characteristics firstly having a constant brightness of number plate, and a high density to the horizontal axis, and the influences of highlighted signal could be reduced by making reflections less through the polarized filter on the camera for any highlighted signal. For the more, the data processing time and the noise reduction are effectively implemented by using the wavelet transform of time-space scale with the considerations on the physical loss and processing time.

  • PDF

X-ray 식각된 PMMA의 다양한 현상조건에 따른 현상특성 (Development Characteristics of PMMA fabricated by X-ray Lithography in Various Development Conditions)

  • 김윤호;박준식;이인규;박순섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.284-287
    • /
    • 2004
  • Micro-structures fabricated by X-ray lithography are largely affected by doses, development conditions and other factors. For these reasons, PMMA development rates and its surface profiles under various development conditions were obseued. Development rates were measured in the rage from 1 to 6 $kJ/cm^3$ using the 9C1 white beamline of Pohang light source(PLS). In this experiment, we observed that development rates of stacked PMMA sheet using Si filter were relatively higher than that of not using Si filter. Furthermore, development rates in condition with the acoustic agitation(1 MHz, 3.67 $W/cm^3$) were twice than that in dipping condition with $35^{\circ}C$ developer considering the PMMA sheets-substrate bond strength

  • PDF

섬유질유물의 포화(Degradation)에 영향을 주는 요인들에 대한 연구

  • 배상경
    • 보존과학연구
    • /
    • 통권11호
    • /
    • pp.1-9
    • /
    • 1990
  • The environmental controls for good conservation of all textile materials are follow as :1) Special RH conditions on textiles keep to the usually advocated 50∼55%.2) The effect of the temperature is too small to worry about in the applicable range, that is $20^{\circ}C$.3) It is important to keep soiling by air borne dirt to a minimum by an air filter or putting textiles in cases.4) Sulphur dioxide must be rekoved by an activated carbon filter or a water spray. And this concentration below $50\muGm^3$ can be regarded assatisfactory.5) Oxygen plays a part of deterioration proceses. The effect of nitrogend andinert gases in sealed show cases should be further studied.6) Ozone is detrimental to textiles. It can be removed by activated carbonfilter.7) The removal of UV radiation and blue light can be expected to increase the lifetime of dyeing and strength of fiber.50 lux is suggested for sensitive textile materials.

  • PDF

A Fiber Laser Spectrometer Demodulation of Fiber Bragg Grating Sensors for Measurement Linearity Enhancement

  • Kim, Hyunjin;Song, Minho
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.312-316
    • /
    • 2013
  • A novel fiber-optic sensor system is suggested in which fiber Bragg grating sensors are demodulated by a wavelength-sweeping fiber laser source and a spectrometer. The spectrometer consists of a diffraction grating and a 512-pixel photo-diode array. The reflected Bragg wavelength information is transformed into spatial intensity distribution on the photo-diode array. The peak locations linearly correspond to the Bragg wavelengths, regardless of the nonlinearities in the wavelength tuning mechanism of the fiber laser. The high power density of the fiber laser enables obtaining high signal-to-noise ratio outputs. The improved demodulation characteristics were experimentally demonstrated with a fiber Bragg grating sensor array with 5 gratings. The sensor outputs were in much more linear fashion compared with the conventional tunable band-pass filter demodulation. Also it showed advantages in signal processing, due to the high level of photo-diode array signals, over the broadband light source system, especially in measurement of fast varying dynamic physical quantities.

이미지프로세싱을 이용한 가공면의 표면거칠기 측정에 관한 연구 (A study on the cutting surface roughness measurement by image processing)

  • 소의열;임영호
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.124-133
    • /
    • 1994
  • Many of non-contact measuring systems are used to estimate surface characteristics owing to their advantages of high speed and undanaged test. In this paper, a new measuring system is proposed to acquire image from CCD camera through back light illumination. Lowpass filter is very useful in view of noise removal and optimum binary image can be made through histogram equalization which is one of the histogram technique to maximize brightness intensity between workpiece and background. Laplacian operator is used to detect workpiece edge from binary image. In case of image treatment applying Laplacian operator, surface roughness is calculated by introducing conversion coefficient for coordinate of pixel which edge is composed of. In summary, the work is concerned with the development of a new technique for roughness measurement by the image processing in turning.

  • PDF

LED 식물공장에서 산란 유리 이용에 의한 상추(Lactuca Sativa L.)의 군락 광분포, 광합성 및 생장 향상 (Improvement of Canopy Light Distribution, Photosynthesis, and Growth of Lettuce (Lactuca Sativa L.) in Plant Factory Conditions by Using Filters to Diffuse Light from LEDs)

  • 강우현;장범;이준우;손정익
    • 원예과학기술지
    • /
    • 제34권1호
    • /
    • pp.84-93
    • /
    • 2016
  • 인공광 식물공장은 조명에 많은 전력이 소요되므로 광이용효율의 향상은 필수적이다. 본 연구에서는 식물공장의 LED 광원에 산란 유리를 사용함으로써 광이용효율을 향상하고자 하였다. 실험에는 Haze factor 40%와 80%의 산란 유리가 적용된 두 가지 처리구와 산란 유리를 사용하지 않은 대조구를 두었다. 3-D 광선추적기법을 이용하여 상추 작물의 군락 광분포를 분석하였으며 군락 광합성률은 밀폐 아크릴 챔버를 이용하여 측정하였다. 각 처리구 별로 16주의 상추를 수경재배 방식으로 28일간 재배하여 생장량을 비교하였다. 시뮬레이션 결과, 모든 처리구에서 작물의 상단부에 광량이 집중되었고 대조구에서 작물 상부에 광량 핫스팟이 발생하며 처리구에 비하여 광이용효율이 감소하였다. 총 광 흡수량은 대조구에서 가장 높았으나 유효 광 흡수량은 처리구에서 더 높았고 산란광의 비율이 높은 처리에서 더 높게 나타났다. 작물의 군락 광합성률과 생장량은 산란 유리를 사용한 처리구에서 대조구에 비해 높게 나타났다. 결과적으로 산란 유리의 이용을 통해 상추의 군락 내 광분포가 개선되었고 군락 광합성률 및 생장량이 증가하여 식물공장의 광이용효율이 향상되는 것으로 나타났다.

시료 채취 조건 및 검사방법에 따른 지하수내 섬유상 물질 검출 양상에 관한 연구 (Effect of Sampling and Analytical Methods on the Fibrous Materials from the Ground Water)

  • 김지용;김정란;정해관;임현술;백남원
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.209-222
    • /
    • 1997
  • Authors surveyed the ground water near the waste disposed from a fiberglass production factory to confirm the presence of glassfiber in the water and to determine the effect of sampling conditions and storage on the recovery of fibrous materials in the ground water. Sample was collected at every 4 hours for 48 hours consecutively. After finishing the 48 hours sample, water sampling was done from each tap after repeated turning on and off the water for 30 seconds at each time. Sample was collected in the two 1.5 liter polyethylene bottle after vigorously shaking the bottle with the same water several times with the flowing tap water. At each paired sample, one bottle was stored stand still at room temperature, and the other sample was filtered immediately after sampling. Water was filtered on the Mixed Cellulose Ester filter with negative pressure. Each sample was divided into upper and lower layer. The other bottle was stored at room temperature standstill for 7 days and filtered in the same fashion as the other pair of sample did. Each MCE filter was divided into 4 pieces and one piece was treated with acetone to make it transparent. Each prepared sample was observed by two researchers under the light and polarizing microscopy, scanning electron microscopy and energy dispersive X-ra microanalysis. Fibers were classified by the morphology and polarizing pattern under the polarizing microscope, and count was done. 1. There was a significant fluctuation in number of the fibers, but there was no specific demonstrable pattern. 2. Non-polarizing fibers frequently disappeared after 7 days's storage. But cluster of fibers were found at the wall of the same container by scratching technique. 3. Polarizing fibers were usually found in between the filter and the manicure pasted area. Possible explanations for this phenomenon will be that either these fibers are very light or have electronic polarity. Hence, these fibers are not able to be attached on the surface of slide glass. 4. Under the scanning electron microscopic examination, the fibers which are not refractive under the light microscopy were identified as glassfiber. Other fibers which is refractive under the polarizing microscopy were identified as magnesium silicate fibers. It is strongly suggested that development of standardized method of sample collection and measurement of fibrous material in the water is needed.

  • PDF

광중합기를 이용한 광학적 치아우식활성도 검사법 (DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT)

  • 이난영;김미라;오유향;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.671-679
    • /
    • 2004
  • 레이저와 플라스마 광, 할로겐 광 중합기를 이용하여 각 개인의 우식 활성토를 측정할 수 있는지를 규명하기 위해 7-8세 아동 45명을 대상으로 치아의 순면과 협면에 각 광원을 조사하고 특수 필터를 사용하여 초기 치아우식증으로 판별된 치아의 개수를 측정하여 기존의 우식활성도 측정방법인 dDfFtT rate와 mutans streptococci 측정법, Lactobacilli 측정법과 비교, 평가하고 그 특이도, 민감도, 예측력을 평가하였다. 1. 아르곤 레이저, 플라스마 광, 할로겐 광 조사시 육안검사시 보다 유의하게 많은 초기우식 병소가 관찰되었다(p<0.05). 2. 아르곤 레이저, 플라스마 광, 할로겐 광을 이용한 우식활성도 측정법은 dDfFtT rate와 양의 상관관계 (${\gamma}=0.42,\;0.41,\;0.39$)를 보였다(p<0.01). 3. 기존의 우식활성도 측정방법을 기준으로 하여 평가한 결과 특이도와 민감도, 예측력은 모두 레이저가 가장 높았으며 플라스마 광, 할로겐 광 순으로 나타났다. 이상의 결과를 종합하여 볼 때 아르곤 레이저와 플라스마 광, 할로겐 광을 이용한 형광법은 모두 양호한 진단학적 지표를 보여줌으로써 향후 광학적 우식활성검사법으로 활용 가능성이 높을 것으로 사료된다.

  • PDF

색광에 대한 두툽상어의 반응 (Response of Cat Shark to the Colored Lights)

  • 양용림
    • 수산해양기술연구
    • /
    • 제19권1호
    • /
    • pp.12-16
    • /
    • 1983
  • 색광에 대한 두툽상어 Scyliorhinus torazame의 행동을 조사하기 위하여, 2가지 서로 다른 색광을 조합하여 수조의 양단에서 동시에 광자극을 가했을 때의 반응을 조사한 결과는 다음과 같다. 1. 수조내에서의 구간별 분포곡선은 대체로 W자형이 되었다. 2. 양색광원쪽에서의 평균분포차는 10.19%(0.17~25.75%)였고, 주간(6.72%)보다 야간(13.66%)에 더 컸다. 3. 두툽상어가 잘 모이는 색광은 주간에는 황색, 백색, 청색, 적색의 순이며, 야간에는 적색, 청색, 백색, 황색의 순으로 나타났다. 4. 조명시간의 경과에 따른 집어율의 변화는 적었으며 비교적 안정하게 변동했는데 주간에 더 안정되었다. 5. 두 가지 색광에 대한 집어율의 차는 조명시간에 관계없이 대체로 뚜렷했는데 주간보다 야간에 더 차가 심했다

  • PDF