• Title/Summary/Keyword: Light filter

Search Result 605, Processing Time 0.022 seconds

Study of Paprika Growth Characteristic on Covering Selective Light Transmitting Filter in Greenhouse (선택적 광 투과에 따른 파프리카 생육특성 연구)

  • Kang, D.H.;Kim, D.E.;Lee, J.W.;Hong, S.J.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2021
  • This study aimed to a basic research for the development of dye-sensitized solar cells that the wavelength band required for crop growth is passed, and the wavelength band that is not necessary for crop growth can be used for the generation of electricity. The transmissivity according to the illuminance was about 10% higher in the Blue filter and the Green filter than in the Red filter, but the transmissivity according to the PPFD was about 10% higher in the Red filter and the Blue filter than in the Green filter. In addition, the greenhouse attached with 30% infrared blocking filter was predicted to have a lower air temperature than other greenhouses, but it was investigated that there was no significant difference. Therefore, it was investigated that the application of the infrared cut filter would not be appropriate in a greenhouse that controls the temperature by opening a window. As a result of investigating, it was found that the Green and Blue filter greenhouses had the severe overgrowth and the stems grew weaker. The fresh weight of paprika in the infrared blocking filter greenhouse was the highest at 678.9g, and the growth of Red filter and the control greenhouses was relatively poor. Photosynthetic rate, amount of transpiration, and stomatal conductivity were the infrared blocking filter and control greenhouse higher than others. On the other hand, the water use efficiency did not show a big difference.

Equivalent Optical Bandwidth of Reflective Electro-Absorption Modulator Based Optical Source with a Broadband Seed Light for a 2.5 Gb/s and Beyond Signal Transmission

  • Kim, Chul Han
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.371-375
    • /
    • 2015
  • The impact of equivalent optical bandwidth on the performance of a system using a reflective electroabsorption modulator (R-EAM) based optical source has been experimentally evaluated with signals operating at 2.5 Gb/s and beyond. The equivalent optical bandwidth of our source with a broadband seed light was simply adjusted by using a bandwidth tunable optical filter. From the measurements, we have estimated the required equivalent optical bandwidth of our source for an error-free transmission (@ bit-error-rate of $10^{-12}$) and a forward error correction (FEC) threshold of $2{\times}10^{-4}$.

The Research & Development of Infra-Red Flame Detector (적외선 불꽃감지기 개발연구)

  • 이복영;권오승;정창기;박상태;조성수
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • The radiant energy from a flaming fire of fuels containing carbonaceous material can be applied to fast growing fire. Raiant energy sensinsing technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not be applied. This study investigated the characteristics of sun light, artificial light and flame radiation light and the foundation technique of flame detecting is established. Pyroelectric element proper for the characteristics of flame radiant energy developed and circuit stabilizing technique, electro-magnetic immunity technique, durable and reliable operating technique to circuits developed.

  • PDF

Advanced Pixel Structure for Higher Aperture Ratio in TFT-LCD

  • Kim, Jong-Hoon;Noh, Sang-Yong;Kang, Shin-Tack;Lee, Jong-Hwan;Choi, Kwang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.17-19
    • /
    • 2008
  • An advanced TFT-LCD structure was proposed to increase aperture ratio (AR). In this structure, metal layers formed below the data lines are used as light-blocking layers, achieving higher AR ratio than that of a conventional structure. Since average misalignment between the metal light-blocking layers and pixel electrodes is smaller than that of black matrixes on color filter glass, substantially less light-blocking areas are needed to achieve misalignment margin. The AR of the LCD panel fabricated by using proposed structure was enhanced by 18.7 % over that of the conventionally structured panel.

  • PDF

Color-Matching Liquid Crystal Display using a Lenticular Lens Array and RGB Light Sources

  • Jeon, Hwa Joon;Park, Gyeungju;Gwag, Jin Seog;Lee, Jong Hoon;Kwon, Jin Hyuk
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.345-349
    • /
    • 2014
  • A direct-lit color-matching liquid crystal display using a lenticular lens array with grouped lens elements that image linear RGB light sources on the RGB subpixels of a color filter to enhance transmittance is designed, simulated, and fabricated. The RGB LED linear light sources were fabricated using small RGB LEDs in a linear array arrangement, and the lenticular lens array consisted of eight units of the same structure with a gap of 2.19 mm. The optical transmittance of the liquid crystal panel was improved by as much as 240% due to the color matching.

Real Time Traffic Signal Plan using Neural Network

  • Choi Myeong-Bok;Hong You-Sik
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.4
    • /
    • pp.360-366
    • /
    • 2005
  • In the past, when there were few vehicles on the road, the T.O.D.(Time of Day) traffic signal worked very well. The T.O.D. signal operates on a preset signal cycling which cycles on the basis of the average number of average passenger cars in the memory device of an electric signal unit. Now days, with increasing many vehicles on restricted roads, the conventional traffic light creates startup-delay time and end-lag-time. The conventional traffic light loses the function of optimal cycle. And so, $30-45\%$ of conventional traffic cycle is not matched to the present traffic cycle. In this paper we proposes electro sensitive traffic light using fuzzy look up table method which will reduce the average vehicle waiting time and improve average vehicle speed. Computer simulation results prove that reducing the average vehicle waiting time which proposed considering passing vehicle length for optimal traffic cycle is better than fixed signal method which doesn't consider vehicle length.

Development of Photo-sensor for Integrated Lab-On-a-Chip (집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

Wide Color Gamut Backlight from Three-band White LED

  • Kim, Il-Ku;Chung, Kil-Yoan
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.67-70
    • /
    • 2007
  • A Wide Color Gamut Backlight system was studied using a three-band white Light-Emitting Diode. A three-band white light-emitting diode (LED) was fabricated using an InGaN-based blue LED chip that emits 445-nm blue peak, and a green phosphor and red phosphor that emit 535-nm green and 621-nm red peak emissions, respectively, when excited by 450-nm blue light. Using for this three-band white LED, wide color gamut backlight unit (BLU) was attained. The luminance of BLU and CIE 1931 chromaticity coordinates was $1,700Cd/m^2$ and (0.337, 0.346). Color filter matching simulations for this configuration show that the three-band white LED backlight can be enhanced by up to 16% over conventional white LED backlight color gamut.

Utilization of Light Microscopy and FFT for MFA Measurement from Unstained Sections of Red Pine (Pinus Densiflora)

  • Kwon, Ohkyung;Lee, Mi-Rim;Eom, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.399-405
    • /
    • 2013
  • This study demonstrates the utilization of light microscopy and Fast Fourier Transform-Peak Finding (FPF) method for microfibril angle (MFA) measurement from unstained sections of red pine (Pinus densiflora). To obtain an image with optimal contrast and resolution for MFA measurement, effects of numerical aperture (NA) of condenser lens and color filters were investigated. About 60% of NA of the maximum condenser NA produced an image with optimal contrast, but a color filter with short wavelength range (DAPI) created images with improved resolution. Manual angle measurement and the FPF method were applied to the image with optimal contrast for MFA measurement. The experimental results from the FPF method were considered to be more repeatable and less subjective than those from the manual angle measurement.

A STUDY ON THE EARLY DETECTION OF ENAMEL CARIES BY THE LUMINESCENCE EXCITED BY ARGON LASER (아르곤 레이저 광감각법의 법랑질 우식증 조기탐지 효과에 관한 연구)

  • Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.313-324
    • /
    • 1997
  • The aim of the present study was to describe an safe and convenient method for the early detection of enamel caries using laser fluorescence. Fluorescence from natually carious lesion of human teeth illuminated by an argon laser(488nm) was observed and photographed using barrier filter. Intact enamel was found to fluorescence with a yellowish light. Whereas, incipient caries lesions in the enamel were dearly visible as dark areas in contrast to the fluorescence surroundings. For evaluation of accuracy of this method, lesion depth measured by the laser fluorescence in light microscope was compared with that polarizing microscope. The results from the present study can be summarized as follows : 1. Enamel caries of smooth surface was observed as pale white spot and undefined outline in ordinary light. Whereas, lesion was clearly visible as dark spot in laser fluorescence. 2. There was no difference between ordinary light view and laser fluorescence in occlusal surface and interproximal surface. 3. There was no significant difference between the lesion depth observed by laser fluorescence with light microscope and polarizing microscope. Apparent correlation exists between two groups.

  • PDF