• 제목/요약/키워드: Light curing time

검색결과 148건 처리시간 0.021초

Comparison of Surface Microhardness of the Flowable Bulk-Fill Resin and the Packable Bulk-Fill Resin according to Light Curing Time and Distance

  • Hyung-Min Kim;Moon-Jin Jeong;Hee-Jung Lim;Do-Seon Lim
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.123-131
    • /
    • 2023
  • Background: As a restorative material used to treat dental caries, the light-curing type resin is widely used, but it has the disadvantage of polymerization shrinkage. The Bulk-Fill composite resin was developed to solve these shortcomings, but the existing research mainly focused on comparing the physical properties of a composite resin and a Bulk-Fill resin. A study on the light curing time and distance of the Bulk-Fill resin itself tend to be lacking. Methods: This study compares the surface microhardness of specimens prepared by varying the light curing time and distance of smart dentin replacement (SDR) as a flowable Bulk-Fill resin and Tetric N-ceram as a packable Bulk-Fill resin, and confirms the polymerization time and distance that becomes the optimum hardness. To determine the hardness of the specimen, it was measured using the Vickers Hardness Number (Matsuzawa MMT-X, Japan). Results: In SDR, the surface microhardness decreased as the distance increased in all time groups in the change distance from the curing tip. In the change of light curing time with respect to the distance from curing tip, the surface microhardness increased as the time increased. In Tetric N-ceram, the surface microharness showed no significant difference in the change of the distance of curing tip in the group of 20 and 60 second. But in the group of 10 and 40 seconds, decreased as the distance increased. The surface microharness increased as the light curing time increased in all distance groups. Conclusion: When using SDR and Tetric N-ceram in clinical practice, it is considered that as the distance from the polymerization reactor tip increases, a longer light curing time than the polymerization time recommended by the manufacturer is required.

광원에 따른 중합광의 복합레진 중합 능력 비교 (POLYMERIZATION ABILITY OF SEVERAL LIGHT CURING SOURCES ON COMPOSITE RESIN)

  • 신혜진;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.156-161
    • /
    • 2003
  • The purpose of this study is to evaluate the polymerization ability of three different light sources by microhardness test. Stainless steel molds of 1, 2, 3, 4 and 5 mm in thickness of 7 mm in diameter were prepared. The hybrid composite Z100 was packed into the hole of the mold and curing light was activated for designated time. Three different light sources, conventional halogen, light emitting diode, and plasma arc, were used for curing of composite. Two different curing times applied ; one is to follow the manufacturers recommendation and the other is to extend the curing time of LED and plasma arc for balancing the light energy with halogen. Immediately after curing, the Vickers hardness was measured at the bottom of specimen. The results were as follows. 1 The composite cured with LED showed equal to higher microhardnesss than halogen. 2. The composite was cured with plasma arc by manufacturers recommendation showed lowest micro-hardness at all thickness. However, when curing time was extended, microhardness was higher than the others. In conclusion, this study suggested that plasma arc needs properly extended curing time.

광중합기의 광원에 따른 브라켓 전단결합강도 비교 (Comparison of the shear bond strength of brackets in regards to the light curing source)

  • 차정열;이기준;박선형;김태원;유형석
    • 대한치과교정학회지
    • /
    • 제36권3호
    • /
    • pp.198-206
    • /
    • 2006
  • 제논 플라즈마 아크 광중합기나 LED 광중합기가 치과영역에 소개된 이후로 기존의 텅스텐 할로겐 광중합기를 사용할 때에 비해 교정장치의 부착시간이 현저하게 줄어들 수 있게 되었다. 제논 플라즈마 아크 광중합기에 대한 중합시간과 전단강도에 대해서는 여러 연구가 있어왔던 반면, LED 광중합기를 이용하여 교정용장치의 부착을 위한 중합시간에 대한 연구는 미진하다. 본 연구의 목적은 LED 광중합기의 중합시간에 따른 결합강도를 플라즈마 아크 광중합기와 비교하여 적절한 브라켓의 부착강도를 얻기 위해 요구되는 중합시간을 알아보는데 있다. 120개의 발치된 사람의 소구치에 컴포짓 레진으로 브라켓을 부착시킨 후 4초, 6초, 8초 동안 플라즈마 아크 광원과 LED 광원으로 각각 중합시켰다. 그 후 결합강도를 만능시험기(Universal Testing Machine)로 계측한 결과, 플라즈마 아크 광중합기에서는 4초 이상에서, LED 광중합기에서는 8초 이상의 중합시간에서 기존의 할로겐 광원을 40초간 노출시켰을 때와 비슷한 전단결합강도를 나타내었다. 플라즈마 아크 광중합기와 LED 광중합기의 중합시간이 접착제 잔류지수 (adhesive remnant index) 수치에 대해 영향을 미치지 않았다.

수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구 (A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME)

  • 김경현;권오승;김현기;백규철;엄정문;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

양생조건에 따른 경량기포콘크리트의 특성 (Properties of Light Weight Foamed Concrete According to Curing Condition)

  • 신상철;최지호;홍성록;김지호;정지용;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.237-239
    • /
    • 2011
  • This study was performed to investigate the influence of curing temperature on the properties of light weight foamed concrete, manufactured on-site construction according to the various experimental factor such as temperature of material, curing temperature in air(5, 10, 20℃), curing time in air(5, 10, 15hour), and target density of hardened state(0.8, 1.2t/㎥). As a result, the influence of the curing temperature on various properties of foamed concrete is greater than curing time. When increasing temperature and time in air curing, progress of hydration is fast and compressive strength is increasing more and more. However, when considering the productivity, minimum curing time is required 15hours at 5℃, 10hours at 10℃, and 5hours at 20℃. If this condition is not required, there is some crack due to volume expansion on the surface of light weight foamed concrete.

  • PDF

광중합 시간과 거리의 변화에 따른 TheraCal LC의 중합도 평가 (Evaluation of the Changes in Polymerization of TheraCal LC with Various Light-curing Time and Distance)

  • 배상용;이제우;라지영
    • 대한소아치과학회지
    • /
    • 제46권4호
    • /
    • pp.392-399
    • /
    • 2019
  • 이 연구의 목적은 tricalcium silicate cement 중 하나인 TheraCal LC의 광중합 시간과 거리에 따른 중합도를 평가하는 것이었다. 금속주형을 이용해 시편을 제작하여 Vickers hardness number (VHN)를 측정하였으며, 중합시간과 조사시간에 따른 시편의 미세경도 값을 비교 분석하였다. 그 결과, 모든 군에서 상면의 VHN이 하면의 VHN보다 유의성 있게 컸다(p < 0.05). 하면의 VHN은 모든 중합거리에서 중합시간이 증가함에 따라 유의하게 증가하였고(p < 0.05), 중합시간이 일정하고 중합거리가 4.0 mm 이상이 되었을 때 유의하게 감소하였다(p < 0.05). 또한 시편을 20초간 중합한 경우 하면의 VHN은 2를 넘지 못했으며 이는 상면의 10%에 해당하였다. 이 연구 결과에 의하면, 모든 중합거리에서 TheraCal LC 시편의 하면까지 중합하기에 20초의 광중합 시간은 충분하지 않았으며, 중합도를 높이기 위해서 중합시간의 증가와 도포 두께의 감소를 고려해볼 필요가 있다.

Microhardness and microleakage of composite resin according to the change of curing light intensity

  • Park, Soo-Man;Shin, Dong-Hoon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.586.2-586
    • /
    • 2001
  • The selection of a curing light is a multifactorial decision. While each method of polymerization presents unique clinical benefits, the optimal light-curing technique remains to be determined. The objective of this study was to check the difference of micro hardness and microleakage according to various light intensity (50, 100, 200, 300, 400, 600 ㎽/$\textrm{cm}^2$) and curing time (10, 20, 40 seconds). A3 color of two composite resin, hybrid type DenFil and submicron type Esthet X were tested.(중략)

  • PDF

Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING)

  • 김정윤;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.638-642
    • /
    • 2001
  • 최근에 소개된 Plasma arc lamp를 이용한 고광도 광조사기는 조사되는 광도를 크게 증가시켜 필요한 조사시간을 단축시키고자하는 연구의 결과중 하나이다. 교정 임상에서 브라켓의 접착시 고광도 광조사기를 사용하여 시술시간을 줄인다면 환자뿐만 아니라, 술자에게도 시간적이나 경제적으로 많은 도움을 줄 것이다. 이 연구의 목적은 Plasma arc light를 사용하여 접착시킨 브라켓의 치면에 대한 전단강도를 측정하고 이를 기존의 할로겐 램프를 이용한 광중합 방법과 비교해보기 위함이다. I군은 할로겐 램프를 사용하는 $XL3000^{(R)}$을 이용하여 총 50초간 광중합하였고 II군은 plasma arc lamp를 사용하는 $Flipo^{(R)}$를 이용하여 2초간 광중합하였으며 III군도 $Flipo^{(R)}$를 이용하여 총 5초간 광중합하여 전단강도 측정을 시행한 결과는 다음과 같다. 1. 세 군의 전단강도의 평균은 비슷한 수치를 나타내었다. 2. 세 군간의 통계학적 유의 차가 없었다(p>0.05).

  • PDF

광원에 따른 조사거리의 증가가 복합레진의 중합도에 미치는 영향 (INFLUENCE OF TIP DISTANCE ON DEGREE OF CONVERSION OF COMPOSITE RESIN IN CURING WITH VARIOUS LIGHT SOURCES)

  • 김상배;박호원
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.273-279
    • /
    • 2004
  • 최근에 소개된 single high-intensity LED 중합기는 이전의 LED 중합기에 비해 높은 광도를 가지며 짧은 중합시간에 적절한 물성을 가질 수 있다고 한다. 본 연구는 single high-intensity LED 중합기의 중합성능을 평가하기 위하여 거리에 따른 중합도를 조사하였다. Mylar strip사이에 복합레진(Filtek Z250)을 넣고 압접시켜 만든 얇은 필름형 시편을 LED 중합기(Elipar Freelight 2, 10초), 플라스마 중합기(Flipo, 6초)와 할로겐 중합기 (XL3000, 20초)를 사용해 0mm, 2mm, 4mm, 6mm에서 광도를 측정하고 중합시켰다. 중합된 시편을 Fourier Transform Infrared Spectrometer(FTIR)를 이용해 중합도를 측정한 후 다음과 같은 결론을 얻었다. 1. 모든 중합기에서 거리가 증가할수록 유의하게 광도가 감소하였으며 LED중합기의 경우 6mm에서 다른 중합기에 비해 가장 많은 광도 감소율을 보였다(p<0.05). 2. 모든 중합기에서 거리가 증가함에 따라 4mm까지는 중합도가 감소하였지만 유의한 차이는 보이지 않았다(p>0.05). 하지만 4mm와 6mm사이에서는 모든 중합기에서 유의하게 감소하였다(p<0.05). 3. 각 거리에 따른 중합기간의 중합도 차이는 0mm, 2mm, 4 mm에서 LED중합기가 다른 중합기보다 유의하게 높은 중합도를 보였으며 (p<0.05) 플라스마 중합기와 할로겐 중합기 사이에서는 유의한 차이가 없었다. 하지만 6 mm에서는 모든 중합기 사이에 유의한 차이를 보이지 않았다(p>0.05).

  • PDF

광중합기의 광도와 시간에 따른 글래스 아이오노머의 치수내 온도변화 (INTRAPULPAL TEMPERATURE CHANGE OF GLASS IONOMER ACCORDING TO LIGHT CURING INTENSITY AND CURING TIME)

  • 김희량;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.387-392
    • /
    • 2001
  • When cavity floor is near the pulp, polymerization of light-activated restorations results in temperature increase. This temperature increase cause by both the exothermic reaction process and the energy absorbed during irradiation. Therefore instating base is required. Most frequently used insulating base is glass ionmer. The purpose of this study was to evaluate intrapulpal temperature changes of glass ionomer according to various curing intensity and curing time. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn for evaluating of temperature changes. glass ionomer material was placed in 2mm. total curing time was 40s: continuous 40s, intermittent 20s, intermittent 10s. Glass ionomer material was cured with 300mW/$\textrm{cm}^2$, 550mW/$\textrm{cm}^2$ light curing unit. The results were as follows : 1. Temperature in pulp increased as curing unit power is increased. 2. Temperature in pulp more increased continuous emission than intermittent emission.

  • PDF