• Title/Summary/Keyword: Light curing light

검색결과 467건 처리시간 0.03초

Microhardness and microleakage of composite resin according to the change of curing light intensity

  • Park, Soo-Man;Shin, Dong-Hoon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.586.2-586
    • /
    • 2001
  • The selection of a curing light is a multifactorial decision. While each method of polymerization presents unique clinical benefits, the optimal light-curing technique remains to be determined. The objective of this study was to check the difference of micro hardness and microleakage according to various light intensity (50, 100, 200, 300, 400, 600 ㎽/$\textrm{cm}^2$) and curing time (10, 20, 40 seconds). A3 color of two composite resin, hybrid type DenFil and submicron type Esthet X were tested.(중략)

  • PDF

복합레진 중합용 가시광선 광중합기의 적정 광강도 유지를 위한 임상적 고찰 (A CLINICAL STUDY ON THE MAINTENANCE OF LIGHT INTENSITY OF VISIBLE-LIGHT CURING MACHINES FOR THE POLYMERIZATION OF COMPOSITE RESINS)

  • 이동수;정태성;김신
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.363-368
    • /
    • 2001
  • 광중합형 복합레진은 일부 성분들이 강한 광학-전자기선에 노출됨으로써 경화된다. 최초의 제품들은 자외선을 이용하여 중합되었다. 초기의 이러한 제품들은 작업시간의 조절가능 기포 형성 감소, 색 안정성 향상으로 각광받았지만, 자외선의 위해 성과 얕은 중합깊이를 극복하지 못해 결국 가시광선 중합형으로 대체되었다. 가시광선 중합형 복합레진의 중합완성도는 단량체(monomer)에서 복합체(polymer)로의 변환율에 의해 결정된다. 결국 수복물의 성공여부는 조사된 가시광선의 중합능력과 밀접한 연관성을 갖는다. 이번 조사의 목적은 현재 임상(치과 병 의원)에서 사용되고 있는 광중합기의 광도를 여러 연구를 통하여 그 신뢰성이 입증된 digital radiometer를 이용해 평가하고, 3가지 기본부품의 결함을 검증해서 임상가들에게 유익한 정보를 주기 위함이다. 조사 결과, 조사 대상 광중합기 중 17.8%가 적절한 중합에 부적절한 상태에 있으며, 46.6%가 광 조사시간을 연장할 필요가 있는 것으로 드러나, 광조사기의 절반 이상이 수복물의 성공적인 중합을 위해서는, 중합시간의 연장을 필요로 하거나, 기계적 결함으로 점검을 필요로 하는 상태에 있었다. 이번 조사로, 현재 치과 병, 의원에서 사용중인 광조사기의 부품성능과 그 관리에 문제가 있음을 알 수 있다. 이러한 결과는, 최근에 이루어진 외국의 조사에서와 유사하였다. 광조사기를 이용한 수복치료의 성공과, 구입당시 수준의 적절한 품질(quality)을 유지하기 위해서는, 광조사기 관리와 부품 교체에 대한 임상가들의 이해가 필요할 것으로 보인다.

  • PDF

감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향 (Effect of infection control barrier thickness on light curing units)

  • 장훈상;이석련;홍성옥;류현욱;송창규;민경산
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.368-373
    • /
    • 2010
  • 연구목적: 본 연구는 감염 조절용 차단막을 여러 겹으로 사용했을 때 광중합기의 광강도와 파장, light diffusion 등에 미치는 영향에 대해 조사하였다. 연구 재료 및 방법: 감염 조절용 차단막은 투명 랩 (크린랩)을 사용하였고 광중합기는 할로겐 광중합기 (Optilux 360)와 LED 광중합기 (Elipar FreeLight 2)를 사용하였다. 차단막을 1겹, 2겹, 4겹, 8겹으로 광중합기의 광섬유말단을 감싸고 휴대용 광강도 측정기 (Cure Rite)로 광중합기의 광강도를 측정하였다. 광중합기를 주문제작한 optical breadboard에 고정시킨 후 휴대용 spectroradiometer (CS-1000)를 이용하여 광중합기의 파장을 측정하였고, DSLR (Nikon D70s)을 이용하여 광중합기의 light diffusion을 사진 촬영하였다. 결과: 광강도 측정 결과는 차단막의 두께가 증가할수록 광강도가 유의하게 감소하였으나 할로겐 광중합기에서 1겹과 2겹 사이에는 유의차가 없었으며, 4겹 이상의 차단막을 투과할 때 광강도가 더 많이 감소하였다. 여러 겹의 차단막을 투과한 광중합기의 전체적인 파장 형태와 peak wavelength의 변화는 관찰되지 않았다. Light diffusion 사진 촬영 시, LED 광중합기에서는 차단막의 두께가 미치는 영향이 없었으나 할로겐 광중합기에서는 차단막을 4겹 사용했을 때부터 중합광이 조사되는 각도가 감소하기 시작하여 8겹 사용했을 때 통계적으로 유의하게 감소하는 것을 볼 수 있었다 (p < 0.05). 결론: 광중합형 복합레진을 광중합할 경우 감염 조절용 차단막이 찢어지는 경우를 대비하여 1겹으로 사용하기 보다는 2겹으로 사용하는 것이 환자간의 교차감염을 예방하는데 유리할 것으로 사료된다.

가시광선의 파장과 광도가 광중합형 복합레진의 경화에 미치는 영향 (THE EFFECTS OF WAVELENGTH AND INTENSITY OF VISIBLE LIGHT ON THE CURING OF VISIBLE LIGHT CURED COMPOSITE RESIN)

  • 이채경;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.149-159
    • /
    • 1989
  • The purpose of this study was to assess the effects of wavelength and intensity of light curing units on the curing of composite resin. The wavelength and intensity of nine units were evaluated with Optical Multichannel Analyzer and Radiometer. Two-part split stainless steel mold with a cylindrical hole-3.0mm in diameter, 6.0mm in hgieht-was prepared. After placing a Mylar strip between two parts, 100 specimens were made by inserting each of four composite resins into the mold and irradiating for 20 seconds with five light units alternatively. The curing depths were measured by scraping method and evaluated by two-way ANOVA. And Vicker's hardness measurements were made on the longitudinally sectioned surface at 0.5mm interval. The results were as follows: 1. Visilux 2 showed a narrow spectral band within the effective wavelength in initiating polymerization and the highest intensity. Translux showed the diffuse spectrum of wavelength and the lower light intensity. 2. Visilux 2 showed the highest curing effect in any composite resin and then followed by Optilux, Efos 35, Heliomat and Translux. (p < 0.01) 3. Durafill showed the deepest curing depth in any light unit and then followed by Bisfil M, Silux and Heliosit. (p < 0.01). 4. Maximum hardness values showed 0.1mm and 0.5mm under top surface and then gradually decreased with depth.

  • PDF

광중합기용 팁과 시판용 청광 차단 렌즈 및 노란색 착색 렌즈의 청광 투과율 비교 융합 연구 (Convergence study of blue light transmittance comparison between tips for light curing machine and commercially available blue light blocking lenses and yellow tinted lenses)

  • 이숙정
    • 한국융합학회논문지
    • /
    • 제12권7호
    • /
    • pp.125-131
    • /
    • 2021
  • 치과에서 사용횟수가 증가하고 있는 광중합형 레진 치료에는 강한 에너지를 가진 청색광이 필요하나, 그 빛은 산란 또한 커서 눈과 관련된 여러 부작용이 나타난다. 산란되는 빛에 노출되는 위험을 줄이고자 색깔 렌즈를 활용해보고자 하였다. 광중합기용 팁들과 청색광 빛의 차단에 효과가 있을 것으로 기대하는 시판용 노란색 계열의 청광 차단 렌즈와 노란색 염료로 착색한 노란색 렌즈를 UV-Vis 스펙트로미터 기기에 놓고 각각 청색광의 투과와 차단을 실험하였다. 결과로 광중합기용 팁들의 청광차단율 평균은 99.49%, 시판용 렌즈들 중 색 농도가 가장 높은 C 렌즈는 99.54%의 높은 청광차단율을 보였다. 노란색으로 착색한 렌즈의 경우에는 착색 농도가 가장 짙은 노란색 착색 C 렌즈가 87.57%의 청광차단율을 보였다. 레진 치료 시 광중합기용 팁과 함께 노란계열의 시판용 렌즈나 착색 렌즈를 착용한다면 청색광에 의한 눈과 관련된 부작용들을 줄일 수 있을 것으로 판단된다.

고출력 발광 다이오드 광중합기의 치면열구전색제 중합능 평가 (Evaluation of High-power Light Emitting Diode Curing Light on Sealant Polymerization)

  • 박영준;이제우;라지영
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.57-63
    • /
    • 2019
  • 이 연구의 목적은 고출력 발광 다이오드 광중합기의 Xtra Power 및 High Power mode의 짧은 중합시간이 레진 치면열구전색제의 중합에 충분한지를 확인하는 것이다. 금속 주형을 이용해 시편을 제작하여 미세경도를 측정하였으며, 기존의 발광 다이오드 광중합기로 중합한 시편의 미세경도와 비교하였다. 그 결과, High Power mode로 8초, Xtra Power mode로 3초 중합한 filled sealant와 High Power mode로 8초, 12초, Xtra Power mode로 6초 중합한 unfilled sealant의 상면과 하면 모두에서 대조군보다 유의하게 낮은 미세경도를 나타냈다(p = 0.000). 이 연구를 통하여 중합 시간과 전색제의 종류를 고려한 특정 조건에서 고출력 발광 다이오드 광중합기의 Xtra Power 및 High Power mode의 짧은 중합시간이 치면열구전색제를 적절히 중합하기에 충분하지 않음을 알 수 있었다.

LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향 (EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT)

  • 정양석;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.623-631
    • /
    • 2007
  • 본 연구는 LED와 플라즈마 광원의 복합레진의 중합시 완속기시 중합방식(soft-start curing)이 수축응력에 미치는 효과를 비교, 평가하고자 하였다. 할로겐 광원으로 40초간 조사하여 복합레진을 중합한 경우와 LED와 플라즈마 광원의 단일광도 중합방식과 완속기시 중합방식으로 할로겐 40초 동안의 광에너지와 총량이 동일하도록 조사시간을 설정하였고 수축응력은 스트레인 게이지(Strain gauge)를 사용하여 측정하였다. 발생되는 수축응력을 비교, 분석 및 평가한 결과 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합 후 200초까지 수축응력이 급격하게 증가하였으나 이후 마지막 측정시간인 800초까지 완만한 증가를 보였다(P<0.05). 2. LED와 플라즈마 광원의 완속기시 중합방법이 단일광도 중합방법에 비해 수축응력이 낮게 나타났다(P<0.05). 3. 할로겐 광원과 LED와 플라즈마 광원의 완속기시 중합의 수축응력 비교에는 유의차가 없었다(P>0.05). 완속기시 중합 방식을 사용할 경우 단일광도 중합 방식보다 수축응력을 감소시킬 수 있어 임상적으로 고광도 광원인 LED와 플라즈마 광원의 경우 완속기시 중합 방식의 사용이 유리하다고 보여진다. 그러나 완속기시 중합시 불충분한 중합을 방지하기 위해서는 완속기시를 보완하는 추가적인 중합시간이 요구될 것으로 사료된다.

  • PDF

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF

의치용 인공치아와 의치상용 레진간의 결합강도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE BOND STRENGTH OF DENTURE TEETH BONDED TO DENTURE BASE MATERIALS)

  • 이주희;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.464-474
    • /
    • 1996
  • A principal advantage of a plastic tooth over a porcelain tooth should be its ability to bond to the denture base material. But plastic teeth could craze and wear easily, so more abrasion resistant plastic denture teeth have been developed. To resist abrasion, the degree of cross-linking was increased, but bonding to denture base meterial became more difficult. The purpose of this study was to evaluate the bond strength of plastic teeth and abrasion resistant teeth bonded to heat-curing, self-curing and light-curing denture base material. Denture tooth molds were chosen that had a>8mm diameter. The denture teeth was bonded to three denture base materials and then machined to the same dimensions. Three denture base materials were used as control groups. Prior to tensile testing, the specimens were thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ for 1000cycles. Tensile testing was performed on an Instron Universal testing mechine. Experimental group ; plastic teeth(Justi Imperial)+heat-curing resin(Lucitone 199) plastic teeth(Justi Imperial)+light-curing resin(Triad) plastic teeth(Justi Imperial)+self-curing resin(Vertex SC) abrasion resistant teeth(IPN)+heat-curing resin(Lucitone 199) abrasion resistant teeth(IPN)+light-curing resin(Triad) abrasion resistant teeth(IPN)+self-curing resin(Vertex SC) Control group ; heat-curing resin(Lucitone 199) light-curing resin (Triad) self-curing resin(Vertex SC). The results were as follows : 1. The denture teeth bonded to heat-curing resin showed the cohesive failure and those bonded to the other resins showed adhesive failure. 2. Tensile bond strength of the plastic teeth bonded to self-curing resin was not significantly greater than bonded to light-curing resin(p>0.05). 3. Tensile bond strength of the abrasion resistant teeth bonded to self-curing resin was not significantly greater than bonded to light-curing resin(p>0.05). 4. Tensile bond strength of the plastic teeth to self-curing resin was not significantly different from that of the abrasion-resistant teeth(p>0.05). 5. Tensile bond strength of the plastic teeth to light-curing resin was significantly greater than that of the abrasion resistant teeth(p<0.01).

  • PDF

Glass ionomer cement 표면의 산부식 효과에 관한 연구 (THE EFFECT OF ACID ETCHING ON GLASS IONOMER CEMENT SURFACES)

  • 한승원;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.1-26
    • /
    • 1993
  • The purpose of this study was to investigate the effect of acid etching on the surface appearance and fracture toughness of five glass ionomer cements. Five kinds of commercially available glass ionomer cements including chemical curing filling type, chemical curing lining type, chemical curing metal reinforced type, light curing tilling type and light curing lining type were used for this study. The specimens for SEM study were fabricated by treating each glass ionomer cement with either visible light curing or self curing after being inserted into a rubber mold (diameter 4mm, depth 1mm). Some of the specimens were etched with 37% phosphoric acid for 0, 15, 30, 60, go seconds, at 5 minutes, 1 hour and 1 day after mixing of powder and liquid. Unetched ones comprised the control group and the others were the experimental groups. The surface texture was examined by using scanning electron microscope at 20 kV. (S-2300, Hitachi Co., Japan). The specimens for fracture toughness were fabricated by curing of each glass ionomer cement previously inserted into a metal mold for the single edge notch specimen according to the ASTME399. They were subjected to a three-point bend test after etching for 0, 30, 60, and 90 seconds at 5 minutes-, 1 hour-and 1 day-lapse after the fabrication of the specimens. The plane strain fracture toughness ($K_{IC}$) was determined by three-point bend test which was conducted with cross-head speed of 0.5 mm/min using Instron universal testing machine (Model No. 1122) following seven days storage of the etched specimens under $37^{\circ}C$, 100% humidity condition. Following conclusions were drawn. 1. In unetched control group, crack was present, but the surface was generally smooth. 2. Deterioration of the surface appearance such as serious dissolving of gel matrix and loss of glass particles occured as the etching time was increased beyond 15 s following Immediate etching of chemical curing type of glass ionomer cements. 3. Etching after 1 h, and 1 d reduced surface damage, 15 s, and 30s etch gave rough surface appearance without loss of glass particle of chemical curing type of glass ionomer cements. 4. Light curing type glass ionomer cement was etched by acid, but there was no difference in surface appearances according to various waiting periods. 5. It was found that the value of plane stram fracture toughness of glass ionomer cements was highest in the light curing filling type as $1.79\;MNm^{-1.5}$ followed by the light curing lining type, chemical curing metal reinforced type, chemical curing filling type and chemical curing lining type. 6. The value of plane stram fracture toughness of the chemical curing lining type glass ionomer cement etched after 5 minutes was lower than those of the cement etched after 1 hour or day or unetched (P < 0.05). 7. Light curing glass ionomer cement showed Irregular fractured surface and chemical curing cement showed smooth fractured surface.

  • PDF