위상이동 그림자 무아레방법을 이용한 형상측정법의 정확도 개선에 관한 연구 (A Study on the Improvement of Accuracy of Surface Measurement in the Phase-Shifting Shadow Moir$\'{e}$ Method)

  • 강영준;유원재;권용기
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.96-102
    • /
    • 1998
  • In this study, the theory and application of phase-shifting shadow moire topography is focused on the non-contact measurement of object surfaces for practical use in the field of production engineering. Shadow moire topography has been studied during last few decades in the area of the optical physics, and now its mathmatical theory has been established. Generally, in case of the classical shadow moire topography, the sensitivity is a few tenths of millimeter in best cases. Here we tried the application of phase-shifting method to the conventional shadow moire topography. But the reference grating and the deformed grating are mutually dependent because it is impossible to obtain uniform phase shifts on the whole Held. Therefore it is difficult to use a phase-shifting method in shadow moire topography. However, it was shown that constant phase-shifting was able to be measured by moving both the grating and light source. Finally we obtained a better result by using this procedure and applied the phase-shifting shadow moire to three dimensional object measurement.

  • PDF

면니트의 CPB 염색에서 염료 구조에 따른 흡진 거동 분석 (Analysis of the Dye Absorption Behavior in Accordance with the Dye Structure in the Cold Pad Batch Dyeing of Cotton Knit)

  • 홍석일;남창우;이우성
    • 한국염색가공학회지
    • /
    • 제28권3호
    • /
    • pp.175-182
    • /
    • 2016
  • To investigate dyeing behaviors in accordance with dye structure in cold pad batch dyeing of cotton knit, monochlorotriazine-vinylsulfone bifunctional dyes and monofluorotriazine-vinylsulfone bifunctional dyes were prepared. The spectral property and solubility of the dyes were tested and compared with the imported dyes. In addition, exhaustion behaviors of individual and mixed dye solutions were measured to examine the influence of dye structure on dyeing behavior in cold pad batch dyeing. The substantivity, fixation, migration index and half dyeing time were also calculated for further analysis of dyeing behavior of the prepared dyes. As a result, both dyes exhibited the superior solubilities and satisfactory light absorption properties. Also, monofluorotriazine-vinylsulfone bifunctional dyes showed moderate sensitivity to alkalinity and proper kinetic index values compared with the monochlorotriazine-vinylsulfone bifunctional dyes and the imported dyes. The results indicated monofluorotriazine-vinylsulfone bifunctional structure of the dye is suitable for cold pad batch dyeing.

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권4호
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

An I-V Circuit with Combined Compensation for Infrared Receiver Chip

  • Tian, Lei;Li, Qin-qin;Chang, Shu-juan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.875-880
    • /
    • 2018
  • This paper proposes a novel combined compensation structure in the infrared receiver chip. For the infrared communication chip, the current-voltage (I-V) convert circuit is crucial and important. The circuit is composed by the transimpedance amplifier (TIA) and the combined compensation structures. The TIA converts the incited photons into photocurrent. In order to amplify the photocurrent and avoid the saturation, the TIA uses the combined compensation circuit. This novel compensation structure has the low frequency compensation and high frequency compensation circuit. The low frequency compensation circuit rejects the low frequency photocurrent in the ambient light preventing the saturation. The high frequency compensation circuit raises the high frequency input impedance preserving the sensitivity to the signal of interest. This circuit was implemented in a $0.6{\mu}m$ BiCMOS process. Simulation of the proposed circuit is carried out in the Cadence software, with the 3V power supply, it achieves a low frequency photocurrent rejection and the gain keeps 109dB ranging from 10nA to $300{\mu}A$. The test result fits the simulation and all the results exploit the validity of the circuit.

스텝 인덱스 멀티모드 광섬유를 이용한 광강도 변조방식 변위센서 설계모델 연구 (Design Model of Intensity Modulation Type Displacement sensor Using Step-index Multimode Optical Fiber)

  • 신우철;홍준희
    • 한국광학회지
    • /
    • 제17권6호
    • /
    • pp.500-506
    • /
    • 2006
  • 본 논문은 광강도 변조방식 광섬유 변위센서의 측정 메커니즘을 수식적으로 모델링하여 측정영역과 감도를 원하는 목적에 따라 유연하게 조정할 수 있는 설계모델을 제안하고 있다. 유도된 모델은 스텝 인덱스 광섬유를 적용한 경우로 제한되고 광섬유 센서의 변위 응답영역 중 front slope 측정영역 해석에 초점을 맞추었다. 또한 광섬유 설계 시 유도된 모델 적용이 용이하도록 수치적분 방식의 해석 프로세스를 소개하고 있다. 제안된 모델과 프로세스는 기본 설계변수 별로 실험결과를 통해 비교검증 되었다. 끝으로 검증된 모델을 통해 기본 설계변수에 따른 광섬유 변위센서의 변위응답 특성 경향을 분석하였다.

목재펠릿시스템의 대체투자 가능성 분석 - 시설과채 사례 - (Replacement Investment with Pallet Fuel System in Greenhouse Fruit and Vegetables)

  • 김성섭;김태후;서상택
    • 농촌지도와개발
    • /
    • 제25권3호
    • /
    • pp.149-160
    • /
    • 2018
  • This study aimed to analyze the replacement investment of the diesel fuel system with the pallet fuel system in the Korean farming sector. Equivalent annual annuity approach was used to resolve a discrepancy of useful life in capital goods and to facilitate investment analyses in an independent perspective. Data was obtained from previous studies on economic analysis of greenhouse tomato, paprika and cucumber. Results showed that the replacement with the pallet fuel system was acceptable irrespective of the remaining period of useful life for the diesel fuel system. In addition, sensitivity analysis with government support level, repair cost, and light and heat energy cost show ed robustness in the possibility of replacement with the pallet fuel system while the speed of replacement was accelerated with an increase in the amount of diesel fuel used and price of diesel fuel, and a decrease in price of the pallet fuel. The result implied that the replacement investment rather than a new investment was appropriate for existing greenhouse farmers and the pallet fuel system was acceptable to replace existing diesel fuel system in producing greenhouse tomato, paprika and cucumber.

Study of Frequency Response Characteristics in Microphone Used by Optical Sensor

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권3호
    • /
    • pp.128-133
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in microphone using optical sensor, acousto-optic sensor system has been implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point has also been determined by measuring the response characteristics. The choosing the point, which has maximum linearity and sensitivity has changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement /analysis program, "Smaart Live" and "USBPre", which are based on PC, and compared the result from an existing capacitance microphone. The measured optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 4 kHz at up to 3 dB.

강건한 얼굴 검출 알고리즘을 위한 YCbCr 컬러 모델과 러프 집합 연구 (A Study on the YCbCr Color Model and the Rough Set for a Robust Face Detection Algorithm)

  • 변오성
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권7호
    • /
    • pp.117-125
    • /
    • 2011
  • 본 논문에서는 특징 기반 방법인 YCbCr 컬러 모델을 이용하여 얼굴색 분포를 분할하고, 전처리 과정에서 양자화를 하여 특징 기반의 단점 중의 하나인 조명에 민감한 것을 둔감하도록 하였다. 또한 러프 집합을 이용하여 패턴의 형태로 가장 근사한 영상의 객체를 선택하는 특성을 가지게 함으로 영상 합성의 정확도를 높였다. 본 논문에서 제안된 얼굴 검출 알고리즘은 다양한 얼굴 크기 및 방향에 관계없이 기존의 알고리즘보다 약 2~3%정도 우수함을 시뮬레이션을 통해 확인하였다.

THE RED COLOR OF MARS FROM OPTICAL SPECTRA

  • LEE, SEUNG-A;LEE, DONG-EUN;JO, YEUNG-HUN;SONG, IN-OK
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.761-763
    • /
    • 2015
  • Colors have been derived from the observed optical spectrum of Mars and Jupiter. It is known that the planets and the Moon emit reflected sunlight and thus their spectra are similar to the spectrum of solar radiation. The question was then why is the color of Mars different from that of other planets, i.e. red, although it would share the same spectrum of reflected sunlight. Can one derive color from the spectrum? Therefore, we observed the optical spectra of the scattered sunlight in day time for the Moon and Mars using a 1-D array spectrograph on the 12-inch reflecting telescope in the Korea Science Academy of KAIST in Busan, Korea. We adopted the International Commission on Illumination (CIE) in 1931 of three spectral sensitivity peaks for the human eye in short, medium and long wavelengths in visible light. The observed spectra were imposed on CIE sensitivities and the color detected by the human eye was derived. The Mars spectrum represents red color and the Moon white. It is a similar color to that which a human would see. This result means that color is easily derived from astronomical spectra. The appearance of the planets surface can be determined for Mars, which is the result of iron oxide.

Cryoscopy 裝置와 方法의 改良에 關한 硏究 (On Automatic Apparatus for Cryoscopy and Improvement in Experimental Method)

  • 신윤경;이준
    • 대한화학회지
    • /
    • 제18권2호
    • /
    • pp.143-149
    • /
    • 1974
  • 從來에 開發된 cryoscopy 裝置는 手動型으로서 一回測定에 所要되는 最少 한時間을 두사람이 測定에 꼬박 關與하여야 하는 不便을 갖는다. 뿐만 아니라 手動攪拌에 依한 不規則的攪拌速度에서 오는 誤差나, Beckmann 溫度計의 感溫部가 나타내는 큰 熱容量 및 判讀時의 視角差차와 波勞度에서 오는 誤差等이 不可避하게 作用한다. 그러므로 本 硏究에서는 이들 誤差를 減少시키기 爲하여 다음과 같이 裝置改良에 依한 自動測定法을 開發하였다. (1) 水槽溫度의 自動精密調節 (2) 感溫部의 熱容量이 매우 작은 thermistor에 依한 溫度測定 (3) 檢流計의 反射光을 感光紙에 照射시켜 轉移溫度를 自動記錄하는 이른바 溫度自動記錄裝置의 開發 (4) 攪拌裝置의 自動化 한편 從前부터 使用되어 오는 10水和物 芒硝는 加入時 一部가 容器壁에 묻어 反應에 關與하지 못하며, 또한 10水和物화물을 部分的으로나마 脫水되지 않은채 保存하여 測定에 使用하기는 어려우므로 本硏究에서는 無水芒硝를 써서 하는 實驗條件을 아울러 究明하였다.

  • PDF