• Title/Summary/Keyword: Light Sensitivity

Search Result 614, Processing Time 0.024 seconds

Robust Reference Intervals for Serum Kappa and Lambda Free Light Chains from a Multi Centre Study Population from Hyderabad, India: Myeloma Diagnostic Implications

  • Mohammed, Noorjahan;Chandran, Priscilla Abraham;Kandregula, Madhavi;Mattaparthi, Ratna Deepika;Gundeti, Sadasivudu;Volturi, Jyotsna;Darapuneni, Radhika;Raju, Sree Bhushan;Dattatreya, Palanki Satya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2605-2610
    • /
    • 2016
  • The International Myeloma Working Group considers the serum free light chain (SFLC) assay to be an adjunct to traditional tests. Apart from the FLC ratio, the absolute values of individual free light chains also are gaining importance as they appear to be more relevant in certain clinical settings. Automated assays are available for their determination. As laboratories put new test systems into use catering to different disease populations, they are required by accreditation and certification bodies to verify or establish performance specifications, including reference intervals (RIs) representative of their population. Our aim was to establish local RIs for SFLC in a multicentre representative healthy population using a robust method. There was no significant relationship between SFLC levels and age, gender and creatinine levels. The 95% RI for ${\kappa}SFLC$ was 4.81 to 33.86mg/L, for ${\lambda}$ SFLC was 5.19 to 23.67mg/L and for ${\kappa}/{\lambda}SFLC$ was 0.36 to 2.33, significantly higher than the values given by the manufacturer. The ${\kappa}/{\lambda}$ SFLC ratio at 2.23, covering 100% of the data, showed 72% sensitivity (95% CI=39.0 - 94.0), 100% specificity (95% CI=71.5 - 100.0), 100% PPV (95% CI=21.5 - 100.0), 95% NPV (95% CI=75.4 - 99.9), and 79% accuracy (95% CI=56.0 - 93.0). In the patient group, kit RI for ${\kappa}/{\lambda}$ SFLC ratio classified 45.5% (n=5) as positive vs 9.1% (n=1) positive by the study RI, while the kit RI for kappa FLC classified 90.9% (n=10) as positive vs 54.5% (n=6), indicating increased probability of false positive test results with the kit RI when applied to our patient population. Appropriate and specific reference intervals and criteria values result in fewer false-positive and false-negative results which means fewer wrong or missed diagnoses.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Effects of Greenhouse Covering Material on Environment Factors and Fruit Yield in Protected Cultivation of Sweet Pepper (파프리카 재배 온실의 피복재 종류에 따른 환경요인과 수량성)

  • Kim, Ho-Cheol;Jung, Sek-Gi;Lee, Jeong-Hyun;Bae, Hyang-Jong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.253-257
    • /
    • 2009
  • To analysis effect of environment factors on productivity of sweet pepper according to greenhouse covering material (glass, plastic film), this was investigated. In glasshouse, outside light was positively correlated with yield as that $100MJ{\cdot}m^{-2}$ of outside light increased $300{\sim}500g{\cdot}m^{-2}$, also cumulative temperature was same tendency. On possibility of model development for yield estimate cumulative temperature was high than outside light. According to covering material, leaf photosynthesis, productivity per out-side light and term in glasshouse was more high 13%, 46%, and 47% compared with plastic film house, respectively. Result of analysis of effect of light, temperature, and $CO_2$ on yield, relative yield coefficient, yield increment coefficient, and yield reduction coefficient in glasshouse were more high 25%, 73%, and 34% compared with plastic film house, respectively. Hence, sweet pepper's growing in glasshouse compare with plastic film house had more productivity, but that had more sensitivity to charge of environment factors.

Efficiency of Phototransduction Cascade in Carp Cones

  • Tachibanaki, Shuji;Tsushima, Sawae;Kawamura, Satoru
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.44-46
    • /
    • 2002
  • In the vertebrate retina, rods mediate twilight vision and cones daylight vision. Rods have been purified easily from the retina, and thus the phototransduction mechanism in rods is now well documented. However, it has not been possible to purify cones in large quantities, and therefore, the knowledge on the mechanism in cones is limited. Here we report purification of carp (Cyprinus carpio) cones with a stepwise Percoll gradient. Using purified cells, we compared the phototransduction mechanism between rods and cones. The results showed that both transducin activation and phosphodiesterase activation are less effective, and visual pigment phosphorylation is faster in cones. These differences explain lower light-sensitivity and briefer photoresponse time course in cones.

  • PDF

A Study on the Parameter Analysis for High Precision Optical Current Sensor Implementation (고정도 광 전류센서 구현을 위한 파라미터 분석 연구)

  • Kim, Young-Soo;Lim, Young-Hoon;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.265-267
    • /
    • 2001
  • In this paper, some optical parameters which have effects on the measuring precision and sensitivity of optical current sensor are analyzed. Each parameter occurs changes of specific characteristics of optical sensor system. The influences of performance and characteristics variation of optical current sensor are described in accordance with the changes of optical output power, optical bias point which is called phase difference, and a specific constant related to sensor material and wavelength of light source.

  • PDF

Cross Talk among Pyroelectric Sensitive Elements in Thermal Imaging Device

  • Bang Jung Ho;Yoon Yung Sup
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.780-783
    • /
    • 2004
  • The two-dimensional modeling of the non-stationary thermal state and voltage responsivity of the sensitive elements usually used in solid-state pyroelectric focal plane arrays are presented. Temperature distributions under periodical thermal excitation and the response of the thermal imaging device, which is composed of the pyroelectric sensitive elements mounted on a single silicon substrate, are numerically calculated. The sensitive element consists of a covering metal layer, infrared polymer absorber, front metal contact, sensitive pyroelectric element, the interconnecting column and the bulk silicon readout. The results of the numerical modeling show that the thermal crosstalk between sensitive elements to be critical especially at low frequency (f < 10Hz) of periodically modulated light. It is also shown that the use of our models gives the possibility to improve the design, operating regimes and sensitivity of the device.

  • PDF

Fluorescece Microscope using Total Internal Reflection for Measuring Biochip (내부 전반사 방식에 의한 바이오칩 측정 장비)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1694-1698
    • /
    • 2007
  • This study suggests a new fluorescence microscope to observe micro-samples within fluorophore in a variety of biomedical fields including the fluorescence analysis of a biochip, such as a DNA micro-array. A fluorescence microscope is a device for irradiating light onto a micro-object, executing an excitation and fluorescence emission process. In this study, it adopts a total internal reflection fluorescence(TIRF) method to excite a whole micro-sample substrate different from an existing way which uses an evanescent wave resulting from a total internal reflection on the micro-sample surface. Suggested TIRF microscope can reduce optical noise and obtain images with higher sensitivity thus obtain precise information about the density, quantity, location, etc. of a flurophore, and can simultaneously process separate images even when plurality of fluorophores having different excitation and fluorescent wavelength ranges is distributed, thus easily obtain information about the fluorophores.

Studies on Inhibition Factors and the Role of Phytochrome in the Floral Induction in Short-day Plants (단일식물의 개화유도를 조절하는 개화억제요소의 규명과 Phytochrome의 역할에 관한 연구)

  • 맹주선
    • Journal of Plant Biology
    • /
    • v.19 no.1
    • /
    • pp.14-18
    • /
    • 1976
  • Inhibition of flowering in Lemna perpusilla 6746 by 30 mM sucrose was reversed by the addition of acetylcholine (>$10^{-4}M) supplemented with 10^{-4}M$ ascorbic acid to 1/10-strength Hunter's growth medium. The reversible effect of acetylcholine was found to be greater at early stages of flowering than in the later period. Promotive effects of both acetylcholine ($10^{-3}M) and eserine(10^{-5}M$) on flowering in the short-day plant under various photoperiodic conditions were studied. It was indicated that the application decreased length of the critical dark period for the floral induction, and it was also shown that the endogenous status of acetylcholine was involved in the floral response which had a correlation with phytochrome. Interruption of inductive dark periods by red irradiation (1min) immediately followed by far-red light (1 min) completely inhibited flowering, while the addition of acetylcholine and eserine to the medium under the same condition slightly promoted flowering, indicating possible involvement of phytochrome system in acetylcholine activity for photoperiodic sensitivity of floral response in Lemna perpusilla 6746.

  • PDF

A geometric analysis of range measurement error (거리 영상 측정 오차의 기하학적 분석)

  • 윤강식;이병욱;박래홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1259-1265
    • /
    • 1997
  • We investigate depth measurement error of a range finder based on triangulation method. Geometric analysis resulted in intuitive understanding of the error sensitivity. We show that the depth error is propostional to the distance between the object andthe camera. The measurement value has the highest accuracy when the line connecting the focal point of the camera and the object is perpendicular to the line joining the object and the light source of herange finder. Also we analyze the error using a perturbation method and verify that the results are identical through an experiment.

  • PDF

Study of Clamp-type Optical Current Transformer using Faraday Effect (Faraday 효과를 이용한 클램프형 광-전류 변류기 연구)

  • 김수길;이용욱;이병호;임용훈;홍선기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.60-65
    • /
    • 2003
  • In this paper, we analyzed theoretically design requirement of a clamp-type optical current transformer(COCT)head, and manufactured a COCT head based on design requirement. Also, we measured and analyzed the current of conductor, and change of optical power and sensitivity with incidence angle of light using COCT head, and demonstrated the feasibility of manufactured COCT through those experiments.