• Title/Summary/Keyword: Light Load

Search Result 953, Processing Time 0.034 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

A STUDY ON THE BOND STRENGTHS BETWEEN GLASS IONOMER CEMENT BASES AND COMPOSITE RESINS (글래스 아이오노머 이장재와 복합레진간의 결합강도에 관한 연구)

  • Kim, Min-Hee;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.520-527
    • /
    • 1999
  • For the purpose of providing some suggestions in selection of filling materials used in 'sandwich technique', the bond strengths between glass ionomer cement bases and composite resins were investigated and compared. For lining materials, 'Vitrebond' and 'Ketac-fil' were used. Using these two as bases, 10 of each following resins were built up on the top ; Z-100 (light curing resin) Clear-fil (chemical curing resin), Bis-core (dual cure resin), Dyract (compomer), therfore 10 specimens of each group and total of 80 specimens were made. After storing specimens in $37^{\circ}C$ deionized water for 24 hours, the shear bond strengths were measured under universal testing machine with 50 kg of full load scale and 1mm/min of cross-head speed and obtained the results as follows : 1. Over Vitrebond base, Z-100 showed the lowest bond strength but the other three did not show any difference in bond strength. 2. Over Ketac-fil base, Clear-fil showed the highest bond strength followed by Dyract, Bis-core, and Z-100 showed the lowest bond strengths. 3. Whereas Clear-fil showed the similar bond strengths on the Vitrebond base as other resins, it showed the highest bond strength on Ketac-fil base, which showed some difference in bond strength by differing GIC bases. 4. The bond strengths between base materials and composite resin showed a stronger resin-dependence tendency in cases with Ketac-fil bases rather than with Vitrebond bases.

  • PDF

Factors Related with Job Satisfaction in Workers - Through the Application of NIOSH Job Stress Model - (직장인의 직무만족도 관련요인 분석 - NIOSH의 직무스트레스 모형을 적용하여 -)

  • Kim, Soon-Lae;Lee, Bok-Im;Lee, Jong-Eun;Rhee, Kyung-Yong;Jung, Hye-Sun
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • This study was conducted to determine the factors affecting job satisfaction in workers by using the Job Stress Model proposed by the National Institute for Occupational Safety and Health (NIOSH). Data were collected from December 1 to December 30, 1999. The subjects were 2,133 workers employed at 155 work sites, who were examined using NIOSH Job Stress questionnaire translated by the Korea Occupational Safety ${\pounds}|$ Health Academy and Occupational Safety ${\pounds}|$ Health Research Institute. SAS/PC program was used for statistical analysis using descriptive analysis. Pearson's correlation coefficient, ANOVA, and Stepwise multiple regression analysis. The results of this study were as follows. 1. According to general characteristics of the subjects, job satisfaction was high in those with less number of children. 2. By work condition, job satisfaction was higher in those who were working in a permanent job position, were working with regular time basis than with shift basis, were working in regular shift hours than in changing shift hours, were working for a short period, and were working less hours and overtime works per week. 3. In terms of physical work environment, job satisfaction was significantly related to 10 physical environmental factors. In other words, job satisfaction was high in workers who were working in an environment with no noise, bright light, temperature adjusted to an appropriate level during summer and winter, humidity adjusted to an appropriate level. well ventilation, clean air, no exposure to hazardous substance during work hour, overall pleasant work environment and not crowded work space. 4. By work-related factors, job satisfaction was high in those with less ambiguity about future job and role, high job control/autonomy, and less workload. On the other hand, job satisfaction was low in those with little utilization of competencies, and much role conflict at work and workload. 5. As for the relationships between job satisfaction and the non-work related factors, job satisfaction was high in workers who were volunteering at different organizations or active in religious activities for 5-10 hours per week. 6. In the relationships between job satisfaction and buffering factors, significantly positive correlations were found between job satisfaction and factors such as support by direct superior, support by peers, and support by spouse, friend and family. 7. There were nine factors that affected job satisfaction in the workers: age, number of children, work hours per week, noise, temperature at the work site during summer, uncomfortable physical environment, role ambiguity, role conflict, ambiguity in job future, work load, no utilization of competencies and social support from direct supervisor. These nine factors accounted for 26% of the total variance in the multiple regression analysis. In conclusion. the following are proposed based on the results of this study. 1. The most important physical environmental factors affecting job satisfaction in workers were noise, role ambiguity, and work load, suggesting a need to develop strategies or programs to manage these factors at work sites. 2. A support system that could promote job satisfaction is needed by emphasizing the roles of occupational health nurses who may be stationed at work sites and manage the factors that could generate job stress. 3. Job satisfaction is one of the three acute responses to stress proposed in NIOSH job stress model (job satisfaction. physical discomfort and industrial accidents). Therefore, further studies need to be conducted on the other two issues.

  • PDF

Apo E4 Genotype as the Alzheimer Indictor in Korean Senior Subjects Aged 50 to 64 Years Old (남녀 노인층에서 Alzheimer위험 예측 인자로써의 Apo E4 Genotype에 관한 연구)

  • Oh, Hyun-Hee;Shin, Eun-Jung;Kim, Hyun-Sook;Lim, Yun-Sook;Park, Mi-Young;Kim, Kkoch-Byul;Kim, Eun-Mee;Lee, Myoung-Sook
    • Journal of Nutrition and Health
    • /
    • v.40 no.7
    • /
    • pp.593-600
    • /
    • 2007
  • Recent studies described the ${\varepsilon}4$ allele of apoE confers a two-to fourfold increased risk for late-onset Alzheimer#s disease (LOAD), but LOAD pathology does not all fit neatly around apo E. Therefore, the goal of this study was to find the association between Alzheimer and apo E4 genotype in the 107 elderly between 50 to 64 years old who visited to FHWC of Sungshin Women#s University. We conducted the questionnaire survey (general & 24 hr dietary recall), anthropometerics (BP, waist & BMI) and blood biochemistry (FBS & lipid profiles). LDL-c and HOMA-IR were calculated by Friedwald#s and Matthew#s formulas. The apo E genotyping was performed by PCR-RFLP method and subjects were divided into three allele groups (${\varepsilon}3$; wild, ${\varepsilon}2$ & ${\varepsilon}4;$ mutants). The apo E allele frequencies were 7.0% for the ${\varepsilon}2$, 83.6% for the ${\varepsilon}3$ and 9.3% for the ${\varepsilon}4$. In comparison with biochemistry characteristics by apo E genotype, FBS was significantly higher in ${\varepsilon}4(129.2{\pm}6.8)$ than that in the others (${\varepsilon}2$: $117{\pm}7.4$, ${\varepsilon}3$: $107.3{\pm}2.2)$ (p<0.01). More than forty percents of ${\varepsilon}4$ group shown the dyslipidemia [high TG (>150mg/dl) & low HDL (<40 mg/dl:male or <50 mg/dl: female)]. The cytokines levels such as IL-1 ${\beta}$, IL-6 and $TNF-{\alpha}$ were not different among three apoE alleles. After the adjusting sex, age & dietary fiber, LDL-c level was siginificantly higher in ${\varepsilon}4$ ($108.3{\pm}7.7$) than that in ${\varepsilon}2$ ($100.4{\pm}8.4$) (p<0.05). According to food intake and the recipe on the basis of 24 hr dietary recall, the elder]y with ${\varepsilon}4$ allele took higher intake frequency of the light -colored vegetable (radish, onion & cabbage) and pan-fried foods (sauteed beef and vegetables, stir-fried vienna with vegetables) than the others. We knew that the elderly with ${\varepsilon}4$ allele had been restricted the calories intakes with high dietary fiber (33.6+2.5 g/d) to maintain the normal level of FBS and LDL-c. On next study, the prevalence of Alzheimer#s disease in this population who has ${\varepsilon}4$ allele on the condition of calories restriction will be continually follow-up.

Changes in the Stability Properties of Methylcellulose Emulsions as Affected by Competitive Adsorption Between Methylcellulose and Tween 20 (메칠셀룰로오스/Tween 20 경쟁 흡착이 메칠셀룰로오스 유화액의 안정도 특성에 미치는 영향)

  • Hong, Soon-Taek
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.10
    • /
    • pp.1278-1286
    • /
    • 2008
  • The effect of Tween 20 addition on changes in the stability of methylcellulose (MC) emulsions (1 wt% MC, 10 wt% n-tetradecane, 20 mM bis-tris buffer, pH 7) was investigated by creaming stability and orthokinetic stability measurements. In the case of MC emulsions containing varying amounts of oil (1$\sim$30 wt%) and no Tween 20 added, creaming stability, judged by mean migration velocity of fat globules ($V_m$), was found to depend on droplet size: the larger the droplet size, the worse the stability [$V_m$: 0.326 $\mu$m $min^{-1}$ ($d_{32}$: 0.32 $\mu$m) ${\rightarrow}V_m$: 0.551 $\mu$m $min^{-1}$ ($d_{32}$: 0.53 $\mu$m)]. With Tween 20, creaming stability was found to be worse than the one without Tween 20, except for MC emulsion containing 0.2 wt% Tween 20. In addition, cream stability was the lowest with the lowest concentration of Tween 20 and a tendency to recover with increasing Tween 20 concentration [$V_m$: 0.598 $\mu$m $min^{-1}$ (0.01 wt%)${\rightarrow}V_m$: 0.389 $\mu$m $min^{-1}$ (0.2 wt%)] was found. From viscosity measurement for aqueous bulk phase of MC emulsions, such a change in the creaming stability was found to coincide well with the results of viscosity measurement. Therefore, it was reasonable to say that creaming stability of MC emulsions containing Tween 20 depended on MC concentration in aqueous bulk phase, which was in turn varied by competitive adsorption between MC and Tween 20 at the oil droplet surface. In case of orthokinetic stability, judged by destabilization time ($t_d$), it was found that the addition of Tween 20 resulted in lowered stability with more pronounce tendency at higher concentrations [$t_d$: 160 min (0.03 wt%)${\rightarrow}t_d$: 100 min (0.2 wt%)]. Moreover, combined with previous results, the orthokinetic stability of MC emulsions containing Tween 20 was found to be exponentially proportional to MC load. In conclusion, competitive adsorption between MC and Tween 20 may affect the stability properties of MC emulsion to varying extents, depending on the concentration of Tween 20.

A Study on Performance and Achievement of Village Health Workers in Rural Primary Health Care Program (농촌 일차 보건사업에 있어서 마을건강원 업무량 및 업적에 관한 연구)

  • Hur, Dal-Young;Lee, Myoung-Sook;Yum, Yong-Tae;Kim, Soon-Duck
    • Journal of agricultural medicine and community health
    • /
    • v.12 no.1
    • /
    • pp.36-53
    • /
    • 1987
  • It is utmostly important to establish the efficient fitable way of peoples' active participation in primary health care especially in the areas where the public or governmental service input for the basic health care is insufficient like as in rural areas of Korea. In light of above reason, this study focused mainly on the evaluation of roles and activities of village health workers (VHWs) who were selected from grass- root level of village people in order to derive further motivation for active participation. This is believed to be a sort of feedback mechanisms. Actually, the authors collected the activity reports of VHWs who had been devoting themselves in the primary health care services of Jeomdong Area, of Yeoju Gun one of Korea University Community Health Action Programmes and survey record on the VHWs activity from correspondent people. 1 hose data were analyzed through computer programmed package. The activities performed by VHWs were limited to the performance in 1985 for conveniance. The summarized results were as follows; 1) General characteristics of VHWs. Among a total of 28 VHWs in the area, about 39.3g of them have been replaced up to the date since the implementation in 1983, because of moving out, occupational employment and of others. The age of majority (75.0%) lied between the range of 30-50, and educational background of 67.9% belonged to category of primary school graduation, about 50% of them experienced to be or were also entiled "chief of women club" of corresponding villages. 2) Work-load of VHWs. Each VHW was assigned for tasks of health care for average 55 households of 248 persons. They shared approximately 6 days a month for the activity in average and it covered 17 cases of basic health care in a month. A half of the VHWs performed home visits irregularly without solidified schedule. 3) Work performance analysis. Informations collected through VHWs were compared with data from official vital registration at local administration center "Myon Office" in 1985. VHWs collected 100.8 of new born, 116.2 of death, 58.3 of move in and 74.8 of move out in comparison with 100.0 of official registration each. Pregnant women of 79.8% of mothers among the total pregnancy of 94 which were confirmed as normally delivered or aborted cases by all means afterwards had been detected by VHWs as being pregnant and all of them received some of antenatal cares by VHWs. All(100%) of delivered women were detected by VHWs through home visits and they were cared postnatally. Whereas, according to the records of birth registration, the places of delivery were clinic in 33.7%, and mother's home in 66.3%, VHWs reported them to be clinic in 48.9%, midwifery in 20.2%. It was cleared that most of misinformation was caused by uncautious filling of birth registration at notification. Among the total of 717 eligible women under age 44 years, family planning status of 92.6% was reported by VHWs confirming practice of control to be 70.8% of reported fertile women. 4) Attitude of VHW on the roles and functions. Although 92.0% of VHWs expressed VHWs to be worthwhile, only 52.0% of them had dignity and satisfaction in their activity and 44.0% of them had passive attitude of working saying they followed direction regardlessly. Concerning difficulties in performance as a VHW, 60.7% of them pointed out lacking of medical and health related knowledge by themselves. Still, 64.0% of them thought visiting unfamilier house to be awful and 40.0% complained forms of activity to be difficult and hard. It was also revealed that 56.6% confessed lack of interest on community health service itself. Most of VHWs needed more educational training especially on clinical fields such as cares of gynecological diseases, hypertension, diabetes, and other chronic diseaes of the aged. Regular on-the-job basic trainings were said to be needed twice a year.

  • PDF

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Boulangerite from the Janggun Mine, Republic of Korea; Contributions to the Knowledge of Ore-Forming Minerals in the Janggun Lead-Zinc-Silver Ores (2) (한국·장군광산산 보울란저라이트에 대하여; 장군 연·아연·은 구성광물의 지식에 대한 기여 (2))

  • Lee, Hyun Koo;Imai, Naoya
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.129-134
    • /
    • 1993
  • At the Janggun mine, boulangerite usually occurs as needles or irregularly-shaped grains, up to $500{{\mu}m}$ in longer dimensions, closely associated with galena, minerals of a tetrahedrite-freibergite series and bournonite in the peripheries of South A and B orebodies and the zone of manganoan carbonates surrounding them. In some places, especially at the top of South B orebody, it occures as "feather ore" consisting of its fine needles or "hairs" in small drusy cavities together with fine-grained euhedral galena, pyrite, manganoan carbonates, quartz, etc. In reflected light, it is bluish grey in colour exhibiting moderate bireflectance and is strongly anisotropic without any internal reflections. Reflectance in air is $R_{max}=43.2$, $R_{min}=35.7$ percent at wavelength of 580 nm, and VHN: $146-173\;kg/mm^2$ at a 50 g-load. The chemical composition on the average from 23 complete spot analyses by electron microprobe is, Pb 56.1, Sb 25.1, S 18.5, Total 99.6 (all in weight percent); the corresponding chemical formula calculated on the basis of S=11 is; $Pb_{5.16}Sb_{3.93}S_{11.0}$ which fulfils approximately the ideal formula $Pb_5Sb_4S_{11}$. The strongest reflections on the X-ray diffraction pattern are; $3.73\;{\AA}\;(10)$, $3.22\;{\AA}\;(5)$, $3.03\;{\AA}\;(4)$ and $2.82\;{\AA}\;(5)$ and the pattern is in harmonic with space group $C^5_{2h}-P2_1/a$. From the textural evidence of the microscopic observations, the mineral is considered to have been formed at the latest stage of hydrothermal lead-zinc-silver mineralization.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.