• Title/Summary/Keyword: Light Floor

Search Result 276, Processing Time 0.03 seconds

Vibration isolation effect of floor impact sound by ceiling structure (바닥충격음에서의 천장구조에 따른 진동절연 효과)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to evaluate factors of ceiling structure influencing to the floor impact sound. For this reasons, we measured the vibration of ceiling and the floor impact sound by ceiling structure. The main results from this study are that ceiling structure makes worse to non-ceiling structure for an effect of air layer in heavy-weight floor impact sound. But it has an effect on light-weight floor impact sound about $2\sim8dB$.

  • PDF

A Study on the Traditional Houses in Young Seo District of Kangwon-Do - Focused on the Floor Plan Types - (강원도(江原道) 영서지방(嶺西地方) 민가(民家)에 관한 연구(硏究) - 평면유형(平面類型)을 중심(中心)으로 -)

  • Ryu, Seung-Yong
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.345-353
    • /
    • 1997
  • The purpose of this study is to find out the distinct characteristics of the floor plan types of the traditional houses in Young Seo District of Kangwon-Do. In the light of this previous studies concerning Korean traditional houses the examination of the natural environment and socio-cultural environment on the house form in terms of the floor plan types.

  • PDF

Review of measurement of impact sound improvement for light-weight floor (경량 바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰)

  • Jang, Gil-Soo;Jung, Kwang-Yong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.950-955
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

Review of measurement of impact sound improvement for light-weight floor (경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

Practical Vibration Analysis of Deck Floor Slab (데크 바닥판 구조물의 실용적인 진동해석)

  • Kim, Gee-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • As long-span and light-weight deck floor slab are flexible and have low inherent damping, the significant floor vibration could be induced by residents' activities. These floor vibrations affect to safety and serviceability of building structures. So the vibration criteria are applied to the quality assessment of building structure. Therefore, the accurate vibration analysis should be performed for the correct assessment of deck floor slab. In this paper, practical analysis method with considering orthotropic rigidity of deck floor is proposed tot the accurate vibration analysis of dock floor slabs with form deck plates.

An Experimental Study or the Prediction Method of Floor Impact Sound Insulation Performance in Apartment House Using Impedance Method(II) (임피던스법을 이용한 공동주택 바닥 충격음 차음성능 예측방법에 관한 실험 적 연구(II) - 경량 표준충격원을 중심으로 -)

  • 김재수;장길수;김선우
    • Journal of KSNVE
    • /
    • v.2 no.1
    • /
    • pp.21-31
    • /
    • 1992
  • In the previous paper, we report a practical floor impact sound level prediction method for a heavyweight impact source(Tire), soft impact source such as children jumping and running. According to these results, the calculated value and the measured value correspond comparatively well, regardless of differences in the floor structures. And the floor impact sound for a heavyweight impact source, soft source was strongly influenced by structural factors such as floor slab stiffness and peripheral support conditions. But the floor impact sound for a light impact source (Tapping machine), hard impact source was influenced by resilient layers, composed of multi-layer in floor structures. Thus, In this paper, 4 actual floor structures, all with differing resilient layers, were calculated using impedance method. When these calculation values were compared with the measured values, approximately all the values fell with one rank of the sound insulation grade, reference curve(L curve) by the JIS standard. So, a sample of measured values and calculated values from floor structures is presented to show the accuracy and appropriateness of the impedance method in domestic.

  • PDF

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

A Study on Technology Commercialization of Indoor Floor Advertising Lighting Devices Applicable to Advertisements and Disaster Situations (광고 및 재난상황에 적용 가능한 실내용 바닥광고 조명장치의 기술사업화 방안 연구)

  • Kwang-Soo Kim;Woon-Seek Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.32-40
    • /
    • 2023
  • Recently, there are some outdoor floor advertising lighting devices as one of the active marketing methods. However, for outdoor use, there are many restrictions due to the Outdoor Advertisement Act, according to requiring high-output heat generation, waterproofing, and AC power, etc. The purpose of this study is to develop a Duo Light product optimized for indoor use through publicity and information guidance in normal times and automatic evacuation route guidance display in case of disaster, in conjunction with disaster safety. To that end, patent search and patent association analyses were conducted, and a comparative analysis with commercial products was conducted as a case study. In addition, prototypes were designed and produced through the review of operation principles, where field environment surveys and self-tests were conducted. Also, technology roadmaps were presented by preparing plans for expandability and advancement of products. For the analysis of technology commercialization, the feasibility of technology commercialization was examined through the analysis of Jolly's Model and Lean Canvas Model. The results of this study will be able to contribute to minimize human damage through the effective response to disasters, which can increase the effect of indoor advertising by using the proposed indoor floor advertising lighting device in advertising and disaster situations.

A Study on the Analysis of Propagation Characteristics for Floor Impact Noise in Apartment Houses (공동주택의 바닥충격음 전달 특성 분석에 관한 연구)

  • Seok Ho-Tae;Cho Kyung-Jae;Cha Min-Chul;Jae Sung-Ho
    • Journal of the Korean housing association
    • /
    • v.16 no.5
    • /
    • pp.91-98
    • /
    • 2005
  • The purpose of this study is to analysis of propagation characteristics for floor impact noise in attendance upon investigating standard of insulation performance, measurement and evaluation, understanding characteristics of a measuring factor for floor impact noise in apartment houses. Four cases which was before occupied apartment in Daegu was selected for experiment. Floor impact noise of measurement and evaluation method which are specified in the Korea Standard 2810-1, 2810-2, 2863-1 and 2863-2 was selected for this study. As the result of this study, 1) Especially, there is not a difference for apartment size, but the apartment of 40py type is lower than 30py's about $1\~2\;dB$ for light-weighted and heavy weighted impact sound. 2) The floor impact sound insulation performance is similar about measurement location of the same floor structure. 3) The floor impact sound insulation performance is not a difference about the slab area.

Rating Floor Impact Noise in Apartment Buildings Through Subjective Evaluation Tests (청감실험에 의한 공동주택 바닥충격음의 평가등급 설정)

  • 전진용;류종관
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.88-95
    • /
    • 2003
  • The auditory experiments based on subjective responses were undertaken for the standard heavy and light weight impact noise and rubber ball impact noise, jumping noise to investigate relations between floor Impact noise levels and subjective responses and to establish the upper/lower limits of floor impact noises. As a result, it was shown that relations between floor Impact noise levels and subjective responses was linear and the lower limit of heavy-weight impact noise was L/sub i, Fmax, AW/=46㏈ and the lower limit of light-weight impact noise was L'/sub n,AW/=56㏈. Finally the 3 subjective classes of floor impact noises were established.